Optimization of PET/CT image quality using the GE "Sharp IR' point-spread function reconstruction algorithm

被引:16
作者
Vennart, Nicholas J. [1 ,2 ]
Bird, Nicholas [1 ]
Buscombe, John [1 ]
Cheow, Heok K. [1 ]
Nowosinska, Ewa [1 ]
Heard, Sarah [1 ]
机构
[1] Cambridge Univ Hosp Fdn Trust, Dept Nucl Med, Cambridge, England
[2] Queen Elizabeth Hosp, Dept Med Phys, Gateshead NE9 6SX, England
关键词
contrast; Discovery; 690; image quality; PET; CT; point-spread function; signal-to-noise; time-of-flight; TIME-OF-FLIGHT; PERFORMANCE; SCANNER; IMPACT; IMPROVEMENT; NOISE; PSF;
D O I
10.1097/MNM.0000000000000669
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
ObjectiveThe objective of this study was to quantify any improvement with the GE Sharp IR' point-spread function (PSF) reconstruction algorithm in addition to ordered subsets expectation maximum (OSEM) and time-of-flight (TOF) reconstruction algorithms and establish the optimum parameters to be used in clinical studies.Materials and methodsWe conducted a range of experiments using the National Electrical Manufacturers Association image quality phantom filled with a 4:1 signal-to-background ratio. We scanned the phantom using the GE Discovery 690 PET/CT scanner. We varied iteration number and Gaussian filtration. Results were compared for OSEM, OSEM+TOF and OSEM+TOF+PSF reconstructions. A sample of 15 whole-body fluorine-18-fluorodeoxyglucose were reconstructed with OSEM+TOF and OSEM+TOF+PSF using a selection of optimum reconstruction parameters determined in phantom studies. Clinicians qualitatively ranked their preferred images to choose optimum parameters.ResultsThe addition of PSF improved signal-to-noise ratios (SNRs), contrast, hot contrast recovery coefficients and noise over OSEM and OSEM+TOF reconstruction algorithms. SNRs were the highest at two iterations and with 0 or 2mm filters with OSEM+TOF+PSF reconstruction in all phantom studies. Clinicians generally favoured OSEM+TOF+PSF reconstruction with three iterations and a 2mm filter.ConclusionPSF reconstruction significantly improved image quality for both clinical and phantom studies. We recommended the optimum reconstruction parameters using three iterations, 24 subsets and a 2mm filter, which improved SNRs by up to 28.8% for small lesions (P<0.05).
引用
收藏
页码:471 / 479
页数:9
相关论文
共 40 条
[21]  
Manjeshwar RM, 2006, IEEE NUCL SCI CONF R, P2804
[22]   Performance comparison of two resolution modeling PET reconstruction algorithms in terms of physical figures of merit used in quantitative imaging [J].
Matheoud, R. ;
Ferrando, O. ;
Valzano, S. ;
Lizio, D. ;
Sacchetti, G. ;
Ciarmiello, A. ;
Foppiano, F. ;
Brambilla, M. .
PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2015, 31 (05) :468-475
[23]  
Melcher CL, 1991, IEEE NUCL SCI S MED, V1, P228
[24]   Prospects for time-of-flight PET using LSO scintillator [J].
Moses, WW ;
Derenzo, SE .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1999, 46 (03) :474-478
[25]   Time of flight in PET revisited [J].
Moses, WW .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2003, 50 (05) :1325-1330
[26]  
MULLANI NA, 1980, J NUCL MED, V21, P1095
[27]   Evaluation of spatial dependence of point spread function-based PET reconstruction using a traceable point-like 22Na source [J].
Murata, Taisuke ;
Miwa, Kenta ;
Miyaji, Noriaki ;
Wagatsuma, Kei ;
Hasegawa, Tomoyuki ;
Oda, Keiichi ;
Umeda, Takuro ;
Iimori, Takashi ;
Masuda, Yoshitada ;
Terauchi, Takashi ;
Koizumi, Mitsuru .
EJNMMI PHYSICS, 2016, 3 (01)
[28]   Patient Weight-Based Acquisition Protocols to Optimize(18)F-FDG PET/CT Image Quality [J].
Nagaki, Akio ;
Onoguchi, Masahisa ;
Matsutomo, Norikazu .
JOURNAL OF NUCLEAR MEDICINE TECHNOLOGY, 2011, 39 (02) :72-76
[29]  
National Electrical Manufacturers Association, 2007, PERF MEAS POS EM TOM
[30]   Fully 3-D PET reconstruction with system matrix derived from point source measurements [J].
Panin, Vladimir Y. ;
Kehren, Frank ;
Michel, Christian ;
Casey, Michael .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 2006, 25 (07) :907-921