Characterization method for calculating diffusion coefficient of drug from polylactic acid (PLA) microneedles into the skin

被引:35
作者
Wu, Libo [1 ]
Shrestha, Pranav [2 ]
Iapichino, Martina [2 ]
Cai, Yicheng [1 ]
Kim, Beomjoon [1 ]
Stoeber, Boris [2 ,3 ]
机构
[1] Univ Tokyo, Inst Ind Sci, Meguro Ku, 4-6-1 Komaba, Tokyo 1538505, Japan
[2] Univ British Columbia, Dept Mech Engn, 2054-6250 Appl Sci Lane, Vancouver, BC V6T 1Z4, Canada
[3] Univ British Columbia, Dept Elect & Comp Engn, 2332 Main Mall, Vancouver, BC V6T 1Z4, Canada
关键词
Microneedle; Polylactic acid (PLA); Rhodamine B; Skin diffusion; Confocal microscopy; RHODAMINE-B; BIOCOMPATIBILITY; BIODEGRADATION; FABRICATION; DESIGN; PROBE; MODEL;
D O I
10.1016/j.jddst.2020.102192
中图分类号
R9 [药学];
学科分类号
1007 ;
摘要
Microneedles are designed for piercing the stratum corneum and delivering drugs into the epidermis and dermis layers of the skin. Their micrometric dimension causes minor or negligible stimulations to sensory nerve fibers in the dermis layer of the skin, making drug administration through microneedles less painful compared to conventional hypodermic needle injection. With the advancement of microneedle related research, an increasing number of drugs are using microneedle-mediated drug delivery in the topical area of the skin, including localized delivery of some highly toxic drugs. It is essential to understand drug diffusion from microneedles to skin to avoid unwanted spread of toxic drugs in non-infected areas. This work aims to 1) deliver into the skin tissue fluorescent rhodamine B as a model drug from coated polylactic acid (PLA) microneedles and dissolvable microneedles; 2) detect and depict the concentration distribution of the model drug from two types of microneedles into the skin tissue respectively; 3) determine a reliable diffusion coefficient of the model drug based on a constant source diffusion model and a limited source diffusion model for dissolvable microneedles and coated PLA microneedles, respectively. Dissolvable microneedles and coated PLA microneedles were designed and fabricated by a novel methodology combining 3D printing, chemical etching, micro-molding and drop coating. Rhodamine B was chosen as the model drug to enable fluorescent detection. Two types of microneedles were mounted to a single patch and inserted into porcine skin to deliver the model drug. After microneedle removal, confocal microscopy was used to monitor the fluorescence intensity of rhodamine B in the skin tissue. Based on an intensity-concentration calibration and two diffusion models, the diffusion coefficients of rhodamine B from the constant source (dissolvable microneedles) and limited source (coated PLA microneedles) to the dermis layer of porcine skin were inferred to be from 3.1 x 10(-8) to 3.6 x 10(-8 )cm(2)/s. This characterization method is expected to offer medical personnel a quantitative understanding of the diffusion process related to microneedle-mediated transdermal drug delivery.
引用
收藏
页数:11
相关论文
共 39 条
[1]   Biodegradation and biocompatibility of PLA and PLGA microspheres [J].
Anderson, James M. ;
Shive, Matthew S. .
ADVANCED DRUG DELIVERY REVIEWS, 2012, 64 :72-82
[2]   FLUORESCENCE SELF-QUENCHING OF THE MOLECULAR-FORMS OF RHODAMINE-B IN AQUEOUS AND ETHANOLIC SOLUTIONS [J].
ARBELOA, FL ;
OJEDA, PR ;
ARBELOA, IL .
JOURNAL OF LUMINESCENCE, 1989, 44 (1-2) :105-112
[3]  
Bancroft J.D., 2008, THEORY PRACTICE HIST, DOI [10.1063/1.5131488, DOI 10.1063/1.5131488]
[4]   Spatially Resolved Two-Color Diffusion Measurements in Human Skin Applied to Transdermal Liposome Penetration [J].
Brewer, Jonathan ;
Bloksgaard, Maria ;
Kubiak, Jakub ;
Sorensen, Jens Ahm ;
Bagatolli, Luis A. .
JOURNAL OF INVESTIGATIVE DERMATOLOGY, 2013, 133 (05) :1260-1268
[5]  
Brogioli D, 2001, PHYS REV E, V63, DOI 10.1103/PhysRevE.63.012105
[6]   Optimal design and fabrication of a microneedle arrays patch [J].
Chang, Kai-Ti ;
Shen, Yung-Kang ;
Fan, Fang-Yu ;
Lin, Yi ;
Kang, Sheng-Chieh .
JOURNAL OF MANUFACTURING PROCESSES, 2020, 54 :274-285
[7]   Controllable coating of microneedles for transdermal drug delivery [J].
Chen, Jianmin ;
Qiu, Yuqin ;
Zhang, Suohui ;
Yang, Guozhong ;
Gao, Yunhua .
DRUG DEVELOPMENT AND INDUSTRIAL PHARMACY, 2015, 41 (03) :415-422
[8]   Biocompatibility, biodegradation and excretion of polylactic acid (PLA) in medical implants and theranostic systems [J].
da Silva, Dana ;
Kaduri, Maya ;
Poley, Maria ;
Adir, Omer ;
Krinsky, Nitzan ;
Shainsky-Roitman, Janna ;
Schroeder, Avi .
CHEMICAL ENGINEERING JOURNAL, 2018, 340 :9-14
[9]   The skin barrier as an innate immune element [J].
Elias, Peter M. .
SEMINARS IN IMMUNOPATHOLOGY, 2007, 29 (01) :3-14
[10]   Effect of microneedle design on pain in human volunteers [J].
Gill, Harvinder S. ;
Denson, Donald D. ;
Burris, Brett A. ;
Prausnitz, Mark R. .
CLINICAL JOURNAL OF PAIN, 2008, 24 (07) :585-594