Label-free electrochemical impedimetric immunosensor for sensitive detection of IgM rheumatoid factor in human serum

被引:30
作者
Chinnadayyala, Somasekhar R. [1 ]
Park, Jinsoo [1 ,2 ]
Abbasi, Muhammad A. [1 ]
Choa, Sungbo [1 ,2 ]
机构
[1] Gachon Univ, Dept Elect Engn, 1342 Seongnamdaero, Seongnam Si 13120, Gyeonggi Do, South Korea
[2] Gachon Univ, Gachon Adv Inst Hlth Sci & Technol, Incheon 21999, South Korea
基金
新加坡国家研究基金会;
关键词
Interdigitated wave type microelectrode array; Self-assembled monolayers; IgM rheumatoid factor; Atomic force microscopy; Electrochemical impedance spectroscopy; AUTOANTIBODIES; PEPTIDE; PROBES;
D O I
10.1016/j.bios.2019.111642
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
The authors report a label-free and direct detection of rheumatoid factor- Immunoglobulin M (IgM-RF) based on an impedimetric-interdigitated wave type microelectrode array (IDW mu E). IDW mu E was functionalized with a self-assembled monolayer (SAM) of thioctic acid for antigen immobilization. The SAM functionalized IDW mu E were characterized by atomic force microscopy, Energy Dispersive X-Ray Spectroscopy, and X-ray photoelectron spectroscopy. The covalent immobilization of IgG-Fc onto the SAM modified electrode arrays was characterized morphologically via AFM and electrochemically via cyclic voltammetry and electrochemical impedance spectroscopy. Impedimetric measurements in the presence of redox probe (Potassium ferrocyanide and potassium ferricyanide) showed a significant change in both the impedance spectrum and charge transfer resistance upon IgM-RF binding. Impedance measurements were target specific and linear with an increase in IgM-RF concentrations between 1 and 200 IU mL(-1) in redox probe and human serum, respectively. The sensor showed detection limits of 0.6 IU mL(-1) in the presence of redox probe and 0.22 IU mL(-1) in the human serum. The biosensor exhibited good reproducibility (relative standard deviation (RSD), 4.96%) and repeatability (RSD, 2.31%) with an acceptable selectivity towards IgM-RF detection. The sensor also showed a good stability for 3 weeks at 4 degrees C in 1X PBS. Therefore, the sensitive and stable immunosensor exhibiting IDW mu E features can be integrated with a miniaturized potentiostat to develop a sensing system that detects IgM-RF for point-of-care applications.
引用
收藏
页数:7
相关论文
共 25 条
[1]   Comparative study of different enzyme immunoassays for measurement of IgM and IgA rheumatoid factors [J].
Bas, S ;
Perneger, TV ;
Kunzle, E ;
Vischer, TL .
ANNALS OF THE RHEUMATIC DISEASES, 2002, 61 (06) :505-510
[2]   Electrochemical biosensors for autoantibodies in autoimmune and cancer diseases [J].
Campuzano, Susana ;
Pedrero, Maria ;
Gonzalez-Cortes, Araceli ;
Yanez-Sedeno, Paloma ;
Pingarron, Jose M. .
ANALYTICAL METHODS, 2019, 11 (07) :871-887
[3]   Relationship between the Origin of Constant-Phase Element Behavior in Electrochemical Impedance Spectroscopy and Electrode Surface Structure [J].
Cordoba-Torres, Pedro ;
Mesquita, Thiago J. ;
Nogueira, Ricardo P. .
JOURNAL OF PHYSICAL CHEMISTRY C, 2015, 119 (08) :4136-4147
[4]   Peptide-coated nanotube-based biosensor for the detection of disease-specific autoantibodies in human serum [J].
Drouvalakis, Katerina A. ;
Bangsaruntip, Sarunya ;
Hueber, Wolfgang ;
Kozar, Leland G. ;
Utz, Paul J. ;
Dai, Hongjie .
BIOSENSORS & BIOELECTRONICS, 2008, 23 (10) :1413-1421
[5]   Clinically relevant discrepancies between different rheumatoid factor assays [J].
Falkenburg, Willem J. J. ;
von Richthofen, Helen J. ;
Koers, Jana ;
Weykamp, Cas ;
Schreurs, Marco W. J. ;
Bakker-Jonges, Liesbeth E. ;
Haagen, Inez-Anne ;
Lems, Willem F. ;
Hamann, Dorte ;
van Schaardenburg, Dirkjan ;
Rispens, Theo .
CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2018, 56 (10) :1749-1758
[6]   Comparing label free electrochemical impedimetric and capacitive biosensing architectures [J].
Fernandes, Flavio C. B. ;
Santos, Adriano ;
Martins, Denise C. ;
Goes, Marcio S. ;
Bueno, Paulo R. .
BIOSENSORS & BIOELECTRONICS, 2014, 57 :96-102
[7]   Rheumatoid Factors: Clinical Applications [J].
Ingegnoli, Francesca ;
Castelli, Roberto ;
Gualtierotti, Roberta .
DISEASE MARKERS, 2013, 2013 :727-734
[8]  
KAPLAN JE, 1990, J ACQ IMMUN DEF SYND, V3, P1096
[9]   Rheumatoid factor measured by fluoroimmunoassay: a responsive measure of rheumatoid arthritis disease activity that is associated with joint damage [J].
Knijff-Dutmer, E ;
Drossaers-Bakker, W ;
Verhoeven, A ;
Veer, GV ;
Boers, M ;
van der Linden, S ;
Van de Laar, M .
ANNALS OF THE RHEUMATIC DISEASES, 2002, 61 (07) :603-607
[10]   Peptide flatlandia: a new-concept peptide for positioning of electroactive probes in proximity to a metal surface [J].
Longo, Edoardo ;
Wright, Karen ;
Caruso, Mario ;
Gatto, Emanuela ;
Palleschi, Antonio ;
Scarselli, Manuela ;
De Crescenzi, Maurizio ;
Crisma, Marco ;
Formaggio, Fernando ;
Toniolo, Claudio ;
Venanzi, Mariano .
NANOSCALE, 2015, 7 (37) :15495-15506