Using Electrode Made of Carbon Nanotubes and Bismuth Oxide for the Determination of Metal Concentration by Anodic Stripping Voltammetry

被引:4
作者
Thi Thu Phuong Nguyen [1 ]
Xuan Gian Trinh [2 ]
Dao Thi To Uyen [3 ,4 ]
机构
[1] Hanoi Univ Ind, Fac Chem Technol, 298 Cau Dien, Hanoi, Vietnam
[2] Vietnam Acad Sci & Technol, Inst Chem, 18 Hoang Quoc Viet, Hanoi, Vietnam
[3] Nguyen Tat Thanh Univ, Ctr Excellence Green Energy & Environm Nanomat CE, 300A Nguyen Tat Thanh,Dist 4, Ho Chi Minh City 755414, Vietnam
[4] Nguyen Tat Thanh Univ, NTT Hitech Inst, Ho Chi Minh City 700000, Vietnam
关键词
HEAVY-METALS; TRACE-METALS; ICP-OES; LEAD; PRECONCENTRATION; CADMIUM; COMPLEXES; ELEMENTS; SENSORS; SAMPLES;
D O I
10.1155/2019/6170967
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
We have successfully manufactured a new electrode modified with bismuth oxide (Bi2O3) using carbon nanotubes (CNTs). The electrode was fabricated to detect cadmium (Cd), lead (Pb), and indium (In) by differential pulse anodic stripping voltammetry (DP-ASV). The electrode surface was studied by scanning electron microscopy (SEM), and the reduction and oxidation processes were studied by cyclic voltammetry (CV) techniques. Operational parameters such as electrode size, bismuth concentration, and electrolytic background were optimized. The DP-ASV method used fabricated electrodes with a linear response range from 1.5-20 mu g center dot L-1 with Cd(II) and Pb(II) and 2.5-20 mu g center dot L-1 with In(III); low detection limit (LOD) of 0.22 mu g center dot L-1 with Cd(II), 0.65 mu g center dot L-1 with In(III), and 0.26 mu g center dot L-1 with Pb(II); and good repeatability with relative standard deviations (RSD) of 2.65%, 2.51%, and 3.34% with Cd(II), Pb(II), and In(III), respectively (n = 8). The electrode can be used to test the content of Cd(II), In(III), and Pb(II) in water.
引用
收藏
页数:7
相关论文
共 50 条
  • [1] Determination of Lead and Cadmium in Sea- and Freshwater by Anodic Stripping Voltammetry with a Vibrating Bismuth Electrode
    Bi, Zhaoshun
    Chapman, Conrad S.
    Salauen, Pascal
    van den Berg, Constant M. G.
    ELECTROANALYSIS, 2010, 22 (24) : 2897 - 2907
  • [2] Individual and simultaneous determination of lead, cadmium, and zinc by anodic stripping voltammetry at a bismuth bulk electrode
    Armstrong, Kristie C.
    Tatum, Clarissa E.
    Dansby-Sparks, Royce N.
    Chambers, James Q.
    Xue, Zi-Ling
    TALANTA, 2010, 82 (02) : 675 - 680
  • [3] CARBON NANOTUBES/IONOPHORE MODIFIED ELECTRODE FOR ANODIC STRIPPING DETERMINATION OF LEAD
    Lou, Tingting
    Pan, Dawei
    Wang, Yuane
    Jiang, Lin
    Qin, Wei
    ANALYTICAL LETTERS, 2011, 44 (10) : 1746 - 1757
  • [4] Bismuth-Coated Iridium Microwire Electrode for the Determination of Trace Metals by Anodic Stripping Voltammetry
    Kyrisoglou, Christos
    Economou, Anastasios
    Efstathiou, Constantinos E.
    ELECTROANALYSIS, 2012, 24 (09) : 1825 - 1832
  • [5] Determination of the fungicide picoxystrobin using anodic stripping voltammetry on a metal film modified glassy carbon electrode
    Dornellas, Rafael M.
    Franchini, Romulo A. A.
    Aucelio, Ricardo Q.
    ELECTROCHIMICA ACTA, 2013, 97 : 202 - 209
  • [6] Anodic Stripping Voltammetry for Simultaneous Determination of Lead and Cadmium using Bismuth-based Electrodes
    Pratiwi, Nur Hasanah
    Azis, Muhammad Yudhistira
    Setyorini, Dian Ayu
    Rahayu, Ria Sri
    ANALYTICAL & BIOANALYTICAL ELECTROCHEMISTRY, 2022, 14 (03): : 331 - 347
  • [7] Determination of Trace Metals by Anodic Stripping Voltammetry Using a Carbon Nanotube Tower Electrode
    Guo, Xuefei
    Yun, Yeoheung
    Shanov, Vesselin N.
    Halsall, H. Brian
    Heineman, William R.
    ELECTROANALYSIS, 2011, 23 (05) : 1252 - 1259
  • [8] A carbon ceramic electrode modified with bismuth oxide nanoparticles for determination of syringic acid by stripping voltammetry
    Robak, Justyna
    Wegiel, Krystian
    Burnat, Barbara
    Skrzypek, Slawomira
    MICROCHIMICA ACTA, 2017, 184 (12) : 4579 - 4586
  • [9] Anodic Stripping Voltammetry of Tin at the Bismuth Film Electrode Using Cetyltrimethylammonium Bromide
    Prior, Chad
    ELECTROANALYSIS, 2010, 22 (13) : 1446 - 1454
  • [10] Determination of Lead in Ambient Aerosol Samples by Anodic Stripping Voltammetry on a Bismuth Film Electrode
    Palomo Marin, Ma Rosario
    Pinilla Gil, Eduardo
    Calvo Blazquez, Lorenzo
    ELECTROANALYSIS, 2011, 23 (01) : 215 - 221