Two-compartment technique to remove ophthalmic viscosurgical devices

被引:40
|
作者
Tetz, MR [1 ]
Holzer, MP [1 ]
机构
[1] Tech Univ Berlin, Eye Clin Charite, D-13353 Berlin, Germany
来源
关键词
D O I
10.1016/S0886-3350(99)00420-4
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
To avoid postoperative intraocular pressure peaks, complete removal of all ophthalmic viscosurgical devices (OVDs) used during cataract surgery is important. Depending on the kind of OVD used, different removal techniques have been applied. We describe a technique that was used in more than 250 eyes for safe removal of OVDs, especially viscoadaptive OVDs such as sodium hyaluronate 2.3% (Healon(R)5). It takes advantage of the viscoadaptive properties of Healon5 and was named the 2-compartment technique. J Cataract Refract Surg 2000, 26:641-643 (C) 2000 ASCRS and ESCRS.
引用
收藏
页码:641 / 643
页数:3
相关论文
共 50 条
  • [21] Expulsion Force Measurements of Ophthalmic Viscosurgical Devices (OVD)
    Lundqvist, M. H.
    Nilsson, S.
    Lundgren, B.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2010, 51 (13)
  • [22] HYDRODYNAMICS IN A TWO-COMPARTMENT BIOREACTOR
    De Jesus, E. B.
    Lima, L. R. P. De Andrade
    Bernardez, L. A.
    Almeida, P. F.
    LATIN AMERICAN APPLIED RESEARCH, 2017, 47 (1-2) : 23 - 28
  • [23] Comparison of two techniques for toric intraocular lens implantation: hydroimplantation versus ophthalmic viscosurgical devices
    Yueqin Chen
    Qian Cao
    Chunyan Xue
    Zhenping Huang
    BMC Ophthalmology, 18
  • [24] Comparison of two techniques for toric intraocular lens implantation: hydroimplantation versus ophthalmic viscosurgical devices
    Chen, Yueqin
    Cao, Qian
    Xue, Chunyan
    Huang, Zhenping
    BMC OPHTHALMOLOGY, 2018, 18
  • [25] A two-compartment model for zinc in humans
    Watson, WS
    Mitchell, KG
    Lyon, TDB
    Kerr, N
    JOURNAL OF TRACE ELEMENTS IN MEDICINE AND BIOLOGY, 1999, 13 (03) : 141 - 149
  • [26] Bimanual RetroIOL aspiration for complete removal of ophthalmic viscosurgical devices
    Dada, T
    Dada, VK
    Sethi, HS
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2003, 29 (04): : 852 - 852
  • [27] 'Flow Out Technique' for Safe and Complete Removal of Ophthalmic Viscosurgical Devices After Phacoemulsification Cataract Surgery
    Kreis, Andreas J.
    Nguyen, Thanh T.
    Jhanji, Vishal
    Vajpayee, Rasik B.
    EYE & CONTACT LENS-SCIENCE AND CLINICAL PRACTICE, 2010, 36 (06): : 356 - 357
  • [28] A two-compartment model of the human retina
    Sisak, S
    Banin, E
    Blumenthal, EZ
    MEDICAL HYPOTHESES, 2004, 62 (05) : 808 - 816
  • [29] Understanding, retaining, and removing dispersive and pseudodispersive ophthalmic viscosurgical devices
    Arshinoff, SA
    Wong, E
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2003, 29 (12): : 2318 - 2323
  • [30] Alteration of free radical development by ophthalmic viscosurgical devices in phacoemulsification
    Takahashi, Hiroshi
    Suzuki, Hisaharu
    Shiwa, Toshihiko
    Sakamoto, Atsuhiro
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2006, 32 (09): : 1545 - 1548