Two-compartment technique to remove ophthalmic viscosurgical devices

被引:40
|
作者
Tetz, MR [1 ]
Holzer, MP [1 ]
机构
[1] Tech Univ Berlin, Eye Clin Charite, D-13353 Berlin, Germany
来源
关键词
D O I
10.1016/S0886-3350(99)00420-4
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
To avoid postoperative intraocular pressure peaks, complete removal of all ophthalmic viscosurgical devices (OVDs) used during cataract surgery is important. Depending on the kind of OVD used, different removal techniques have been applied. We describe a technique that was used in more than 250 eyes for safe removal of OVDs, especially viscoadaptive OVDs such as sodium hyaluronate 2.3% (Healon(R)5). It takes advantage of the viscoadaptive properties of Healon5 and was named the 2-compartment technique. J Cataract Refract Surg 2000, 26:641-643 (C) 2000 ASCRS and ESCRS.
引用
收藏
页码:641 / 643
页数:3
相关论文
共 50 条
  • [1] Ophthalmic viscosurgical devices
    Bissen-Miyajima, Hiroko
    CURRENT OPINION IN OPHTHALMOLOGY, 2008, 19 (01) : 50 - 54
  • [2] Novel Technique for Descemetorhexis Under Ophthalmic Viscosurgical Devices and Air
    Coco, Giulia
    Pagano, Luca
    Borgia, Alfredo
    Kaye, Stephen B.
    Romano, Vito
    CORNEA, 2021, 40 (09) : 1215 - 1217
  • [3] Endotoxins in ophthalmic viscosurgical devices
    Dick, HB
    Augustin, AJ
    Pakula, T
    Pfeiffer, N
    EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2003, 13 (02) : 176 - 184
  • [4] Performance and safety of two ophthalmic viscosurgical devices in cataract surgery
    Zeller, Kristina
    Ruiss, Manuel
    Pilwachs, Caroline
    Leisser, Christoph
    Findl, Oliver
    SPEKTRUM DER AUGENHEILKUNDE, 2025,
  • [5] New terminology: Ophthalmic viscosurgical devices
    Arshinoff, S
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2000, 26 (05): : 627 - 628
  • [6] Prefilled syringes and usability of ophthalmic viscosurgical devices
    Shiba, Takuya
    Tsuneoka, Hiroshi
    CLINICAL OPHTHALMOLOGY, 2014, 8 : 1697 - 1702
  • [7] Silicone oil bubbles in ophthalmic viscosurgical devices
    Ohrstrom, A
    Behndig, A
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2002, 28 (03): : 389 - 389
  • [8] Detecting Endotoxin Contamination of Ophthalmic Viscosurgical Devices
    Buchen, Shelley Y.
    Calogero, Don
    Hilmantel, Gene
    Eydelman, Malvina B.
    OPHTHALMOLOGY, 2012, 119 (07) : E11 - E18
  • [9] Silicone oil bubbles in ophthalmic viscosurgical devices
    Lanzl, IM
    Merté, RL
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2002, 28 (12): : 2069 - 2069
  • [10] Influence of ophthalmic viscosurgical devices on intraoperative aberrometry
    Masket, Samuel
    Fram, Nicole R.
    Holladay, Jack T.
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2016, 42 (07): : 990 - 994