Smaller Anterior Chamber Volume Is Associated With Higher Risk of Intraocular Pressure Elevation After Laser Peripheral Iridotomy: A 1-Year Follow-Up Study

被引:3
作者
Zhou, Rouxi [1 ]
Li, Fei [1 ]
Gao, Kai [1 ]
Zhang, Xiulan [1 ]
机构
[1] Sun Yat Sen Univ, Zhongshan Ophthalm Ctr, State Key Lab Ophthalmol, Guangzhou 510060, Peoples R China
来源
ASIA-PACIFIC JOURNAL OF OPHTHALMOLOGY | 2021年 / 10卷 / 02期
关键词
anterior chamber volume; glaucoma; laser iridotomy;
D O I
10.1097/APO.0000000000000317
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: The aim of this study was to analyze the predictive value of swept-source optical coherence tomography (SS-OCT) derived anterior-segment volumetric parameters such as anterior chamber volume (ACV) in the long-term follow-up of primary angle closure disease (PACD). Design: Longitudinal observational study. Methods: In this single-center longitudinal observational study, PACD patients undergoing laser peripheral iridotomy (LPI) were recruited. Anterior segment images of the patients were captured using SS-OCT before LPI, and at 1 week, 1 month, 3 months, 6 months, and 1 year after LPI. Ninety eyes of 81 subjects were enrolled, and 72 eyes of 72 subjects finished the 1 year follow-up. Data of all the 81 subjects were included for analysis. Intraocular pressure (IOP) elevation was defined as IOP >21 mm Hg at any time point after LPI. The association between baseline trabecular-iris space area 750 mu m from scleral spur (TISA750), ACV and iris volume (IV), and IOP elevation were analyzed using logistic regression. Results: Eighty-one subjects were included, 59 were female, and 22 were male, with a mean age of 60.98 +/- 9.44 years. IOP elevation appeared in 14 eyes. Mean TISA750 was negatively associated with IOP elevation (OR = 0.94, P = 0.02). The correlation of TISA750 with IOP elevation varies across quadrants and there was only significant association in temporal TISA750 (OR - 0.98, P - 0.046), whereas in the other 3 quadrants, there was no significant association. Greater ACV was associated with lower risk of IOP elevation (OR = 0.80, P= 0.031), whereas IV was not associated with IOP elevation. Conclusions: ACV is a reliable and accurate predictor for the outcome of PACD. Due to its 3-dimensional nature, the robustness of ACV is greater than traditional angle width parameters such as TISA750.
引用
收藏
页码:188 / 191
页数:4
相关论文
共 21 条
  • [1] Acute primary angle closure-treatment strategies, evidences and economical considerations
    Chan, Poemen P.
    Pang, Jason C.
    Tham, Clement C.
    [J]. EYE, 2019, 33 (01) : 110 - 119
  • [2] The Effect of Phacoemulsification on Intraocular Pressure in Glaucoma Patients A Report by the American Academy of Ophthalmology
    Chen, Philip P.
    Lin, Shan C.
    Junk, Anna K.
    Radhakrishnan, Sunita
    Singh, Kuldev
    Chen, Teresa C.
    [J]. OPHTHALMOLOGY, 2015, 122 (07) : 1294 - 1307
  • [3] Angle closure and angle-closure glaucoma: what we are doing now and what we will be doing in the future
    Friedman, David S.
    Foster, Paul J.
    Aung, Tin
    He, Mingguang
    [J]. CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2012, 40 (04) : 381 - 387
  • [4] Laser peripheral iridotomy for the prevention of angle closure: a single-centre, randomised controlled trial
    He, Mingguang
    Jiang, Yuzhen
    Huang, Shengsong
    Chang, Dolly S.
    Munoz, Beatriz
    Aung, Tin
    Foster, Paul J.
    Friedman, David S.
    [J]. LANCET, 2019, 393 (10181) : 1609 - 1618
  • [5] Longitudinal Changes of Angle Configuration in Primary Angle-Closure Suspects The Zhongshan Angle-Closure Prevention Trial
    Jiang, Yuzhen
    Chang, Dolly S.
    Zhu, Haogang
    Khawaja, Anthony P.
    Aung, Tin
    Huang, Shengsong
    Chen, Qianyun
    Munoz, Beatriz
    Grossi, Carlota M.
    He, Mingguang
    Friedman, David S.
    Foster, Paul J.
    [J]. OPHTHALMOLOGY, 2014, 121 (09) : 1699 - 1705
  • [6] Randomized trial of early phacoemulsification versus peripheral iridotomy to prevent intraocular pressure rise after acute primary angle closure
    Lam, Dennis S. C.
    Leung, Dexter Y. L.
    Tham, Clement C. Y.
    Li, Felix C. H.
    Kwong, Yolanda Y. Y.
    Chiu, Thomas Y. H.
    Fan, Dorothy S. P.
    [J]. OPHTHALMOLOGY, 2008, 115 (07) : 1134 - 1140
  • [7] Longitudinal Changes in Anterior Segment Parameters After Laser Peripheral Iridotomy Assessed by Anterior Segment Optical Coherence Tomography
    Lee, Kyoung Sub
    Sung, Kyung Rim
    Shon, Kilhwan
    Sun, Jae Hong
    Lee, Jong Rak
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2013, 54 (05) : 3166 - 3170
  • [8] Optical Coherence Tomography Imaging for Glaucoma - Today and Tomorrow
    Leung, Christopher Kai-Shun
    [J]. ASIA-PACIFIC JOURNAL OF OPHTHALMOLOGY, 2016, 5 (01): : 11 - 16
  • [9] Volumetric parameters-based differentiation of narrow angle from open angle and classification of angle configurations: an SS-OCT study
    Li, Fei
    Zhou, Rouxi
    Gao, Kai
    Jin, Ling
    Zhang, Xiulan
    [J]. BRITISH JOURNAL OF OPHTHALMOLOGY, 2020, 104 (01) : 92 - 97
  • [10] Acute primary angle closure - Configuration of the drainage angle in the first year after laser peripheral iridotomy
    Lim, LS
    Aung, T
    Husain, R
    Wu, YJ
    Gazzard, G
    Seah, SKL
    [J]. OPHTHALMOLOGY, 2004, 111 (08) : 1470 - 1474