Optimal design of organic Rankine cycle recovering LNG cold energy with finite heat exchanger size

被引:25
作者
Choi, Hong Wone [1 ]
Na, Sun-Ik [1 ]
Bin Hong, Sung [1 ]
Chung, Yoong [1 ]
Kim, Dong Kyu [2 ]
Kim, Min Soo [1 ]
机构
[1] Seoul Natl Univ, Dept Mech Engn, Seoul 08826, South Korea
[2] Chung Ang Univ, Sch Mech Engn, Seoul 06974, South Korea
基金
新加坡国家研究基金会;
关键词
LNG cold Energy; Organic Rankine cycle; Optimal allocation; Size constraint; Working fluid; LIQUEFIED NATURAL-GAS; LOW-GRADE HEAT; ENTROPY GENERATION MINIMIZATION; TEMPERATURE WASTE HEAT; POWER CYCLE; THERMOECONOMIC ANALYSIS; THERMODYNAMIC ANALYSIS; WORKING FLUIDS; CRYOGENIC EXERGY; OPTIMIZATION;
D O I
10.1016/j.energy.2020.119268
中图分类号
O414.1 [热力学];
学科分类号
摘要
An optimization study, under a size constraint, was carried out for an organic Rankine cycle (ORC) combined with an LNG regasification plant for recovering LNG cold energy. Typically, many researchers approached to an optimization problem by assuming pinch point or minimum approach temperature difference. As a different point of view, the size constraint was considered in that resources such as thermal energy and equipment size are limited in a real problem. Given this situation, adequate allocation of finite resources is an important issue for the system to maximize performance. Thus, the aim of this study is to understand how to properly utilize the resources when LNG cold energy and total conductance of heat exchangers are limited. Accordingly, the influences of heat duty allocation, UA allocation, and superheating a turbine's intake on net power were mainly taken into account. Results indicate that, when total conductance for system design increases, the ORC should take more heat duty and total conductance should be weighted to an evaporator. In most cases, the size of heat exchangers should be weighted in the order of evaporator, condenser, and trim heater, provided that total conductance for system design is sufficiently available. (C) 2020 Published by Elsevier Ltd.
引用
收藏
页数:18
相关论文
共 64 条
[1]   USE OF LIQUID NATURAL-GAS AS HEAT SINK FOR POWER CYCLES [J].
ANGELINO, G .
JOURNAL OF ENGINEERING FOR POWER-TRANSACTIONS OF THE ASME, 1978, 100 (01) :169-177
[2]   Binary ORC (organic Rankine cycles) power plants for the exploitation of medium-low temperature geothermal sources - Part A: Thermodynamic optimization [J].
Astolfi, Marco ;
Romano, Matteo C. ;
Bombarda, Paola ;
Macchi, Ennio .
ENERGY, 2014, 66 :423-434
[3]   A comparative study of power optimization in low-temperature geothermal heat source driven R125 transcritical cycle and HFC organic Rankine cycles [J].
Baik, Young-Jin ;
Kim, Minsung ;
Chang, Ki-Chang ;
Lee, Young-Soo ;
Yoon, Hyung-Kee .
RENEWABLE ENERGY, 2013, 54 :78-84
[4]   Comparative study of liquefied natural gas (LNG) cold energy power generation systems in series and parallel [J].
Bao, Junjiang ;
Yuan, Tong ;
Zhang, Lei ;
Zhang, Ning ;
Zhang, Xiaopeng ;
He, Gaohong .
ENERGY CONVERSION AND MANAGEMENT, 2019, 184 :107-126
[5]   A review of working fluid and expander selections for organic Rankine cycle [J].
Bao, Junjiang ;
Zhao, Li .
RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2013, 24 :325-342
[7]   Fundamentals of exergy analysis, entropy generation minimization, and the generation of flow architecture [J].
Bejan, A .
INTERNATIONAL JOURNAL OF ENERGY RESEARCH, 2002, 26 (07) :545-565
[8]  
Bejan A., 1997, ADV ENG THERMODYNAMI, V2nd
[9]   Analysis and optimization of cascade Rankine cycle for liquefied natural gas cold energy recovery [J].
Choi, In-Hwan ;
Lee, Sangick ;
Seo, Yutaek ;
Chang, Daejun .
ENERGY, 2013, 61 :179-195
[10]  
Dai BM, 2019, ENERG CONVERS MANAGE, V197, P15