摘要
Context.-Thromboelastography (TEG) is a whole blood, real-time analyzer measuring the viscoelastic properties of the hemostasis process and allowing for individualized goal-directed therapy. However, routine use of TEG requires validation of sample storage effect on clot parameters. Objectives.-To establish the minimum time required for equilibration time and the maximum time for sample storage for all commercially available TEG tests for the new-generation TEG 6s and to determine how those times compare with the older generation TEG 5000. Design.-Citrated and heparinized whole blood samples obtained from 20 healthy donors were analyzed for clot parameters at multiple time points for both the TEG 6s and the TEG 5000. Samples were activated with the citrated multichannel cartridge or the platelet-mapping cartridge in the TEG 6s or with recalcified kaolin in the TEG 5000. Results.-All blood samples yielded TEG parameter results within reference ranges and had a tendency toward hypercoagulable profiles with increased storage time. Sample storage resulted in increased platelet inhibition with significant differences at 4 hours in the plateletmapping cartridge (arachidonic acid percentage of inhibition, P = .002; adenosine diphosphate percentage of inhibition, P = .02). Conclusions.-For nonemergent cases or in a central laboratory setting, all tests provided reliable results for up to 4 hours in the citrated multichannel cartridge and for 3 hours for platelet function information in the plateletmapping cartridge. In emergent/urgent situations in which the sample needs to be run immediately, RapidTEG and functional fibrinogen tests may be preferred.
引用
收藏
页码:569 / 577
页数:9
相关论文
共 44 条
[1]   Minimum specimen volume requirements for routine coagulation testing - Dependence on citrate concentration [J].
Adcock, DM ;
Kressin, DC ;
Marlar, RA .
AMERICAN JOURNAL OF CLINICAL PATHOLOGY, 1998, 109 (05) :595-599
[2]   Preoperative Point-of-Care Platelet Function Testing in Cardiac Surgery [J].
Agarwal, Seema ;
Johnson, Robert Ian ;
Shaw, Matthew .
JOURNAL OF CARDIOTHORACIC AND VASCULAR ANESTHESIA, 2015, 29 (02) :333-341
[4]   Assessment, Mechanisms, and Clinical Implication of Variability in Platelet Response to Aspirin and Clopidogrel Therapy [J].
Ben-Dor, Itsik ;
Kleiman, Neal S. ;
Lev, Eli .
AMERICAN JOURNAL OF CARDIOLOGY, 2009, 104 (02) :227-233
[5]   The use of citrated whole blood in thromboelastography [J].
Bowbrick, VA ;
Mikhailidis, DP ;
Stansby, G .
ANESTHESIA AND ANALGESIA, 2000, 90 (05) :1086-1088
[6]   Can platelet aggregometry be standardized? [J].
Breddin, HK .
PLATELETS, 2005, 16 (3-4) :151-158
[7]   Massive transfusion policies at trauma centers participating in the American College of Surgeons Trauma Quality Improvement Program [J].
Camazine, Maraya N. ;
Hemmila, Mark R. ;
Leonard, Julie C. ;
Jacobs, Rachel A. ;
Horst, Jennifer A. ;
Kozar, Rosemary A. ;
Bochicchio, Grant V. ;
Nathens, Avery B. ;
Cryer, Henry M. ;
Spinella, Philip C. .
JOURNAL OF TRAUMA AND ACUTE CARE SURGERY, 2015, 78 :S48-S53
[8]   Citrate storage affects Thrombelastograph® analysis [J].
Camenzind, V ;
Bombeli, T ;
Seifert, B ;
Jamnicki, M ;
Popovic, D ;
Pasch, T ;
Spahn, DR .
ANESTHESIOLOGY, 2000, 92 (05) :1242-1249
[9]   Traumatic brain injury causes platelet adenosine diphosphate and arachidonic acid receptor inhibition independent of hemorrhagic shock in humans and rats [J].
Castellino, Francis J. ;
Chapman, Michael P. ;
Donahue, Deborah L. ;
Thomas, Scott ;
Moore, Ernest E. ;
Wohlauer, Max V. ;
Fritz, Braxton ;
Yount, Robert ;
Ploplis, Victoria ;
Davis, Patrick ;
Evans, Edward ;
Walsh, Mark .
JOURNAL OF TRAUMA AND ACUTE CARE SURGERY, 2014, 76 (05) :1169-1175
[10]   A novel Thrombelastograph® tissue factor/kaolin assay of activated clotting times for monitoring heparin anticoagulation during cardiopulmonary bypass [J].
Chavez, JJ ;
Foley, DE ;
Snider, CC ;
Howell, JC ;
Cohen, E ;
Muenchen, RA ;
Carroll, RC .
ANESTHESIA AND ANALGESIA, 2004, 99 (05) :1290-1294