Determination of Vanadium Isotope Compositions in Carbonates Using an Fe Coprecipitation Method and MC-ICP-MS

被引:17
作者
Dong, Lin-Hui [1 ]
Wei, Wei [1 ]
Yu, Cheng-Long [1 ]
Hou, Zhen-Hui [1 ,2 ]
Zeng, Zhen [3 ]
Chen, Tianyu [4 ]
Huang, Fang [1 ,2 ]
机构
[1] Univ Sci & Technol China, Sch Earth & Space Sci, CAS Key Lab Mantel Mat & Environm, Hefei 230026, Anhui, Peoples R China
[2] Univ Sci & Technol China, CAS Ctr Excellence Comparat Planetol, Hefei 230026, Anhui, Peoples R China
[3] Chinese Acad Sci, Inst Soil Sci, State Key Lab Soil & Sustainable Agr, Nanjing 210008, Jiangsu, Peoples R China
[4] Nanjing Univ, Sch Earth Sci & Engn, State Key Lab Mineral Deposits Res, Nanjing 210023, Jiangsu, Peoples R China
基金
中国国家自然科学基金;
关键词
CHROMIUM ISOTOPES; TRACE-METALS; CR-ISOTOPE; OXYGENATION; ADSORPTION; FRACTIONATION; COMPLEXATION; ACCUMULATION; MOLYBDENUM; ATMOSPHERE;
D O I
10.1021/acs.analchem.0c04800
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Vanadium isotope compositions (delta(V-51)) in marine carbonates are a potential proxy to trace global redox states of ancient oceans. Although high-precision delta(V-51) analyses are available for many geological materials, carbonate-hosted delta(V-51) data have not been reported yet due to extremely high matrix elements and low V contents (generally below 10 mu g g(-1)). In this study, we developed an Fe coprecipitation method combined with an Fe column to preconcentrate V from the major matrix elements and subsequent four-step chromatographic procedures to further purify V in carbonates. The delta(V-51) values were measured using a sample-standard bracketing method by MC-ICP-MS. The robustness of this method was assessed by analyzing element-doped and matrix-spiked synthetic carbonate solutions containing an in-house delta(V-51) standard, USTC-V. The mean delta(V-51) value of the synthetic carbonate solutions (0.06 +/- 0.08%; 2SD, n = 33) is in good agreement with the recommended value of the USTC-V relative to the Oxford AA solution (0.07 +/- 0.08%; 2SD, n = 347). In addition, the consistency in the delta(V-51) value of the igneous carbonatite standard, COQ-1, which was processed in parallel with the whole purification (- 0.48 +/- 0.04%; 2SD, n = 3) and a four-step chromatographic procedure (-0.43 +/- 0.08%; 2SD, n = 3), further validates the robustness of our method. For the first time, we obtained delta(V-51) values of four carbonate reference materials: JDo-1, -0.56 +/- 0.09% (2SD, n = 27); JLs-1, -0.61 +/- 0.14% (2SD, n = 33); GBW07217a, -0.79 +/- 0.09% (2SD, n = 6); GBW07214a, -0.51 +/- 0.13% (2SD, n = 48). The long-term external precision of carbonate-hosted delta(V-51) analyses is better than +/- 0.14% (2SD). Our method can be applied to measure carbonate-hosted delta(V-51) to trace the evolution in global marine redox states throughout the Earth's history.
引用
收藏
页码:7172 / 7179
页数:8
相关论文
共 50 条
  • [41] Rubidium Isotope Measurements of Low-Rb Geological Materials by MC-ICP-MS
    Zhang, Ya-Qi
    Wei, Wei
    Zhang, Zhuoying
    Hu, Xia
    Yu, Hui-Min
    Huang, Fang
    GEOSTANDARDS AND GEOANALYTICAL RESEARCH, 2024,
  • [42] High-Precision Fe and Mg Isotope Ratios of Silicate Reference Glasses Determined In Situ by Femtosecond LA-MC-ICP-MS and by Solution Nebulisation MC-ICP-MS
    Oeser, Martin
    Weyer, Stefan
    Horn, Ingo
    Schuth, Stephan
    GEOSTANDARDS AND GEOANALYTICAL RESEARCH, 2014, 38 (03) : 311 - 328
  • [43] Lithium isotope analysis of natural and synthetic glass by laser ablation MC-ICP-MS
    le Roux, Petrus J.
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2010, 25 (07) : 1033 - 1038
  • [44] A Systematic Investigation of the Effects of Standard-Sample Concentration Mismatch during Fe Isotope Measurement by MC-ICP-MS
    King-Doonan, Elizabeth K.
    Bilenker, Laura D.
    Weis, Dominque
    Gordon, Kathy
    Fourny, Anais
    Patton, Genna M.
    Zhao, Ye
    GEOSTANDARDS AND GEOANALYTICAL RESEARCH, 2024, 48 (02) : 309 - 330
  • [45] Quantitative Separation of Molybdenum and Rhenium from Geological Materials for Isotopic Determination by MC-ICP-MS
    Pearce, Christopher R.
    Cohen, Anthony S.
    Parkinson, Ian J.
    GEOSTANDARDS AND GEOANALYTICAL RESEARCH, 2009, 33 (02) : 219 - 229
  • [46] An improved method of Cr purification for high precision measurement of Cr isotopes by double spike MC-ICP-MS
    Zhu, Jian-Ming
    Wu, Guangliang
    Wang, Xiangli
    Han, Guilin
    Zhang, Lixin
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2018, 33 (05) : 809 - 821
  • [47] Preparation of standards for in situ sulfur isotope measurement in sulfides using femtosecond laser ablation MC-ICP-MS
    Chen, Lu
    Chen, Kaiyun
    Bao, Zhian
    Liang, Peng
    Sun, Tiantian
    Yuan, Honglin
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2017, 32 (01) : 107 - 116
  • [48] One-step separation of Cu, Fe, Zn and Cd and isotope ratio analysis by MC-ICP-MS for geological samples
    Li, Hai-tao
    Li, Xing
    Li, Ming
    Guo, Wei
    Jin, Lan-lan
    Zhu, Zhen-li
    Hou, Qing-ye
    Hu, Sheng-hong
    ANALYTICAL METHODS, 2022, 14 (28) : 2782 - 2792
  • [49] High-Resolution In Situ Fe Isotope Measurements of Silicate Minerals and Glasses by Femtosecond Laser Ablation MC-ICP-MS
    Rabin, Segolene
    d'Abzac, Francois-Xavier
    Chmeleff, Jerome
    Poitrasson, Franck
    Gregoire, Michel
    GEOSTANDARDS AND GEOANALYTICAL RESEARCH, 2024, 48 (03) : 619 - 635
  • [50] Cadmium Isotope Ratios of Standard Solutions and Geological Reference Materials Measured by MC-ICP-MS
    Li, Dandan
    Li, Meng-Lun
    Liu, Wen-Ran
    Qin, Zhen-Zhen
    Liu, Sheng-Ao
    GEOSTANDARDS AND GEOANALYTICAL RESEARCH, 2018, 42 (04) : 593 - 605