Determination of Vanadium Isotope Compositions in Carbonates Using an Fe Coprecipitation Method and MC-ICP-MS

被引:17
作者
Dong, Lin-Hui [1 ]
Wei, Wei [1 ]
Yu, Cheng-Long [1 ]
Hou, Zhen-Hui [1 ,2 ]
Zeng, Zhen [3 ]
Chen, Tianyu [4 ]
Huang, Fang [1 ,2 ]
机构
[1] Univ Sci & Technol China, Sch Earth & Space Sci, CAS Key Lab Mantel Mat & Environm, Hefei 230026, Anhui, Peoples R China
[2] Univ Sci & Technol China, CAS Ctr Excellence Comparat Planetol, Hefei 230026, Anhui, Peoples R China
[3] Chinese Acad Sci, Inst Soil Sci, State Key Lab Soil & Sustainable Agr, Nanjing 210008, Jiangsu, Peoples R China
[4] Nanjing Univ, Sch Earth Sci & Engn, State Key Lab Mineral Deposits Res, Nanjing 210023, Jiangsu, Peoples R China
基金
中国国家自然科学基金;
关键词
CHROMIUM ISOTOPES; TRACE-METALS; CR-ISOTOPE; OXYGENATION; ADSORPTION; FRACTIONATION; COMPLEXATION; ACCUMULATION; MOLYBDENUM; ATMOSPHERE;
D O I
10.1021/acs.analchem.0c04800
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Vanadium isotope compositions (delta(V-51)) in marine carbonates are a potential proxy to trace global redox states of ancient oceans. Although high-precision delta(V-51) analyses are available for many geological materials, carbonate-hosted delta(V-51) data have not been reported yet due to extremely high matrix elements and low V contents (generally below 10 mu g g(-1)). In this study, we developed an Fe coprecipitation method combined with an Fe column to preconcentrate V from the major matrix elements and subsequent four-step chromatographic procedures to further purify V in carbonates. The delta(V-51) values were measured using a sample-standard bracketing method by MC-ICP-MS. The robustness of this method was assessed by analyzing element-doped and matrix-spiked synthetic carbonate solutions containing an in-house delta(V-51) standard, USTC-V. The mean delta(V-51) value of the synthetic carbonate solutions (0.06 +/- 0.08%; 2SD, n = 33) is in good agreement with the recommended value of the USTC-V relative to the Oxford AA solution (0.07 +/- 0.08%; 2SD, n = 347). In addition, the consistency in the delta(V-51) value of the igneous carbonatite standard, COQ-1, which was processed in parallel with the whole purification (- 0.48 +/- 0.04%; 2SD, n = 3) and a four-step chromatographic procedure (-0.43 +/- 0.08%; 2SD, n = 3), further validates the robustness of our method. For the first time, we obtained delta(V-51) values of four carbonate reference materials: JDo-1, -0.56 +/- 0.09% (2SD, n = 27); JLs-1, -0.61 +/- 0.14% (2SD, n = 33); GBW07217a, -0.79 +/- 0.09% (2SD, n = 6); GBW07214a, -0.51 +/- 0.13% (2SD, n = 48). The long-term external precision of carbonate-hosted delta(V-51) analyses is better than +/- 0.14% (2SD). Our method can be applied to measure carbonate-hosted delta(V-51) to trace the evolution in global marine redox states throughout the Earth's history.
引用
收藏
页码:7172 / 7179
页数:8
相关论文
共 50 条
  • [31] Cadmium isotope ratio measurements in environmental matrices by MC-ICP-MS
    Pallavicini, Nicola
    Engstrom, Emma
    Baxter, Douglas C.
    Ohlander, Bjorn
    Ingri, Johan
    Rodushkin, Ilia
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2014, 29 (09) : 1570 - 1584
  • [32] Chromatographic purification of antimony for accurate isotope analysis by MC-ICP-MS
    Liu, Jianfeng
    Chen, Jiubin
    Zhang, Ting
    Wang, Yina
    Yuan, Wei
    Lang, Yunchao
    Tu, Chenglong
    Liu, Liangzhi
    Birck, Jean-Louis
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2020, 35 (07) : 1360 - 1367
  • [33] Investigation of mass dependence effects for the accurate determination of molybdenum isotope amount ratios by MC-ICP-MS using synthetic isotope mixtures
    Malinovsky, Dmitry
    Dunn, Philip J. H.
    Petrov, Panayot
    Goenaga-Infante, Heidi
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2015, 407 (03) : 869 - 882
  • [34] A high performance method for the accurate and precise determination of silicon isotopic compositions in bulk silicate rock samples using laser ablation MC-ICP-MS
    Zhang, Chenxi
    Zhao, He
    Zhang, Wen
    Luo, Tao
    Li, Ming
    Zong, Keqing
    Liu, Yongsheng
    Hu, Zhaochu
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2020, 35 (09) : 1887 - 1896
  • [35] Zinc Isotope Measurement by MC-ICP-MS in Geological Certified Reference Materials
    Wang, Jing
    Tang, Dong-Mei
    Yuan, Qing-Han
    Su, Ben-Xun
    Li, Wen-Jun
    Gao, Bing-Yu
    Bao, Zhi-An
    Zhao, Ye
    GEOSTANDARDS AND GEOANALYTICAL RESEARCH, 2023, 47 (04) : 969 - 982
  • [36] Sulfur isotope analysis by MC-ICP-MS and application to small medical samples
    Albalat, Emmanuelle
    Telouk, Philippe
    Balter, Vincent
    Fujii, Toshiyuki
    Bondanese, Victor Packy
    Plissonnier, Marie-Laure
    Vlaeminck-Guillem, Virginie
    Baccheta, Justine
    Thiam, Ndieme
    Miossec, Pierre
    Zoulim, Fabien
    Puisieux, Alain
    Albarede, Francis
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2016, 31 (04) : 1002 - 1011
  • [37] A validated analytical procedure for boron isotope analysis in plants by MC-ICP-MS
    Xiao, Jun
    Vogl, Jochen
    Rosner, Martin
    Deng, Li
    Jin, Zhangdong
    TALANTA, 2019, 196 : 389 - 394
  • [38] Innovative Determination of Zinc Isotope Ratios in Geological Reference Materials: A Combined Precipitation and Anion Exchange Resin Method by MC-ICP-MS
    Nie, Xiaojuan
    Bao, Zhian
    Zong, Chunlei
    Peng, Deyi
    Lv, Nan
    Yuan, Honglin
    ATOMIC SPECTROSCOPY, 2024, 45 (04) : 298 - 308
  • [39] High intermediate precision Sm isotope measurements in geological samples by MC-ICP-MS
    Bai, Jiang-Hao
    Lin, Mang
    Zhong, Song-Xiong
    Deng, Yi-Nan
    Zhang, Le
    Luo, Kai
    Wu, Hao
    Ma, Jin-Long
    Wei, Gang-Jian
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2023, 38 (03) : 629 - 637
  • [40] Measurement of sulfur isotope ratios in trace amounts of dissolved sulfate by MC-ICP-MS
    Moon, Jonghan
    Joo, Young Ji
    Kang, Jung Ok
    Sim, Min Sub
    JOURNAL OF THE GEOLOGICAL SOCIETY OF KOREA, 2021, 57 (01) : 99 - 108