Microstructural investigation using synchrotron radiation X-ray microtomography reveals taste-masking mechanism of acetaminophen microspheres

被引:21
|
作者
Guo, Zhen [1 ,2 ]
Yin, Xianzhen [1 ,3 ]
Liu, Congbiao [1 ,4 ]
Wu, Li [1 ]
Zhu, Weifeng [4 ]
Shao, Qun [3 ]
York, Peter [3 ]
Patterson, Laurence [2 ]
Zhang, Jiwen [1 ,4 ]
机构
[1] Chinese Acad Sci, Ctr Drug Delivery Syst, Shanghai Inst Mat Med, 555 Zuchongzhi Rd, Shanghai 201203, Peoples R China
[2] Univ Bradford, Sch Life Sci, Inst Canc Therapeut, Bradford BD7 1DP, W Yorkshire, England
[3] Univ Bradford, Bradford BD7 1DP, W Yorkshire, England
[4] Jiangxi Univ Tradit Chinese Med, Key Lab Modern Preparat Chinese Mat Med, Minist Educ, Nanchang 330004, Peoples R China
基金
中国国家自然科学基金;
关键词
Taste masking; Lipid microspheres; Dissolution test; Microstructure; Synchrotron radiation X-ray computed microtomography; Three dimensional reconstruction; ORALLY DISINTEGRATING TABLETS; CONTROLLED-RELEASE KINETICS; OSMOTIC PUMP TABLETS; BITTER TASTE; COMPLEXATION APPROACH; SOLUBLE DRUG; FORMULATION; GRANULES; PELLETS; IBUPROFEN;
D O I
10.1016/j.ijpharm.2015.12.045
中图分类号
R9 [药学];
学科分类号
1007 ;
摘要
The structure of solid drug delivery systems has considerable influence on drug release behaviors from particles and granules and also impacts other properties relevant to release characteristics such as taste. In this study, lipid-based microspheres of acetaminophen were prepared to mask the undesirable taste of drug and therefore to identify the optimal formulation for drug release. Synchrotron radiation X-ray computed microtomography (SR-mu CT) was used to investigate the fine structural architectures of microspheres non-destructively at different sampling times during drug release test, which were simultaneously determined to quantitatively correlate the structural data with drug release behaviors. The results demonstrated that the polymeric formulation component, namely, cationic polymethacrylate (Eudragit E100), was the key factor to mask the bitter taste of acetaminophen by inhibiting immediate drug release thereby reducing the interaction intensity of the bitter material with the oral cavity taste buds. The structure and morphology of the microspheres were found to be influenced by the shape and particle size of the drug, which was also an important factor for taste-masking performance. The quantitative analysis generated detailed structural information which was correlated well with drug release behaviors. Thus, SR-mCT has been proved as a powerful tool to investigate the fine microstructure of particles and provides a new approach in the design of particles for taste masking. (C) 2015 Elsevier B.V. All rights reserved.
引用
收藏
页码:47 / 57
页数:11
相关论文
共 50 条
  • [1] Microstructural investigation to the controlled release kinetics of monolith osmotic pump tablets via synchrotron radiation X-ray microtomography
    Li, Haiyan
    Yin, Xianzhen
    Ji, Junqiu
    Sun, Lixin
    Shao, Qun
    York, Peter
    Xiao, Tiqiao
    He, You
    Zhang, Jiwen
    INTERNATIONAL JOURNAL OF PHARMACEUTICS, 2012, 427 (02) : 270 - 275
  • [2] Structural changes of polymer-coated microgranules and excipients on tableting investigated by microtomography using synchrotron X-ray radiation
    Kajihara, Ryusuke
    Noguchi, Shuji
    Iwao, Yasunori
    Suzuki, Yoshio
    Terada, Yasuko
    Uesugi, Kentaro
    Itai, Shigeru
    INTERNATIONAL JOURNAL OF PHARMACEUTICS, 2015, 481 (1-2) : 132 - 139
  • [3] Microstructural analysis of recycled concrete using X-ray microtomography
    Leite, M. B.
    Monteiro, P. J. M.
    CEMENT AND CONCRETE RESEARCH, 2016, 81 : 38 - 48
  • [4] Investigation of the microstructure and mineralogical composition of urinary calculi fragments by synchrotron radiation X-ray microtomography: a feasibility study
    Kaiser, Jozef
    Hola, Marketa
    Galiova, Michaela
    Novotny, Karel
    Kanicky, Viktor
    Martinec, Petr
    Scucka, Jiri
    Brun, Francesco
    Sodini, Nicola
    Tromba, Giuliana
    Mancini, Lucia
    Koristkova, Tamara
    UROLOGICAL RESEARCH, 2011, 39 (04): : 259 - 267
  • [5] Investigation of the microstructure and mineralogical composition of urinary calculi fragments by synchrotron radiation X-ray microtomography: a feasibility study
    Jozef Kaiser
    Markéta Holá
    Michaela Galiová
    Karel Novotný
    Viktor Kanický
    Petr Martinec
    Jiří Ščučka
    Francesco Brun
    Nicola Sodini
    Giuliana Tromba
    Lucia Mancini
    Tamara Kořistková
    Urological Research, 2011, 39 : 259 - 267
  • [6] Estimation of microstructural properties from synchrotron X-ray microtomography and determination of the REV in paper materials
    Rolland du Roscoat, S.
    Decain, M.
    Thibault, X.
    Geindreau, C.
    Bloch, J.-F.
    ACTA MATERIALIA, 2007, 55 (08) : 2841 - 2850
  • [7] Studying model suspensions using high resolution synchrotron X-ray microtomography
    Islam, Syed F.
    Mancini, Lucia
    Sundara, Ramana V.
    Whitehouse, Steve
    Palzer, Stefan
    Hounslow, Michael J.
    Salman, Agba D.
    CHEMICAL ENGINEERING RESEARCH & DESIGN, 2017, 117 : 756 - 772
  • [8] 3D experimental investigation of the microstructure of cement pastes using synchrotron X-ray microtomography (μCT)
    Gallucci, E.
    Scrivener, K.
    Groso, A.
    Stampanoni, M.
    Margaritondo, G.
    CEMENT AND CONCRETE RESEARCH, 2007, 37 (03) : 360 - 368
  • [9] Visualization and quantitative profiling of mixing and segregation of granules using synchrotron radiation X-ray microtomography and three dimensional reconstruction
    Liu, Ruihao
    Yin, Xianzhen
    Li, Haiyan
    Shao, Qun
    York, Peter
    He, You
    Xiao, Tiqiao
    Zhang, Jiwen
    INTERNATIONAL JOURNAL OF PHARMACEUTICS, 2013, 445 (1-2) : 125 - 133
  • [10] The damage mechanism of the metastable β-titanium alloy Ti5321 with specific microtexture using synchrotron X-ray microtomography
    Gu, B.
    Dang, N.
    Zhang, J. J.
    Liu, G. Q.
    Gu, X. F.
    Yang, P.
    JOURNAL OF ALLOYS AND COMPOUNDS, 2023, 968