Photoreceptor identification and quantitative analysis for the detection of retinal disease using AO-OCT imaging

被引:0
|
作者
Wells-Gray, Elaine M. [1 ]
Choi, Stacey S. [1 ,2 ]
Ohr, Matthew [2 ]
Cebulla, Colleen M. [2 ]
Doble, Nathan [1 ,2 ]
机构
[1] Ohio State Univ, Coll Optometry, 338 W 10th Ave, Columbus, OH 43210 USA
[2] Ohio State Univ, Dept Ophthalmol & Visual Sci, Havener Eye Inst, 915 Olentangy River Rd, Columbus, OH 43212 USA
来源
OPHTHALMIC TECHNOLOGIES XXIX | 2019年 / 10858卷
关键词
Adaptive optics; Optical coherence tomography; Retina; Photoreceptors; Cones; Segmentation; Age-related macular degeneration; OPTICAL COHERENCE TOMOGRAPHY; ADAPTIVE-OPTICS; ULTRAHIGH-RESOLUTION; MACULAR DEGENERATION;
D O I
10.1117/12.2510659
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Adaptive optics (AO) enables imaging of cellular structures in the retina that are not visible with clinical imaging techniques, providing the potential for earlier detection of retinal disease and enhanced monitoring of progression. The aim of this work was to develop automated, quantitative techniques for characterizing the morphology of the posterior retina in AO-OCT B-scans. Images were obtained from a custom-built dual-modality AO-optical coherence tomography-scanning laser ophthalmoscopy (AO-OCT-SLO) imaging system. Automated segmentation and cone identification procedures were developed and applied to images from two groups: healthy controls and dry age-related macular degeneration (AMD) subjects. Results from the automated routines were compared to measurements made manually by an expert human reviewer, demonstrating good agreement. Results from the control subjects showed decreasing cone inner and outer segment lengths with increasing distance from the fovea. The cone outer segment tip (COST) layer had a greater variation in axial position compared to the inner segment/outer segment (IS/OS) junction. Results from the AMD group indicate that disruption in the COST layer over drusen occurs earlier and to a greater extent than the IS/OS junction, which may be useful in the detection of emerging drusen.
引用
收藏
页数:9
相关论文
共 50 条
  • [1] Does transverse chromatic aberration limit performance of AO-OCT retinal imaging?
    Miller, Donald T.
    Cense, Barry
    Koperda, Eric
    Jonnal, Ravi S.
    Gao, Weihua
    1ST CANTERBURY WORKSHOP ON OPTICAL COHERENCE TOMOGRAPHY AND ADAPTIVE OPTICS, 2008, 7139
  • [2] Single shot retinal imaging with AO spectral OCT
    Zhang, Y
    Rha, J
    Jonnal, RS
    Miller, DT
    Coherence Domain Optical Methods and Optical Coherence Tomography in Biomedicine IX, 2005, 5690 : 548 - 555
  • [3] AO-OCT for in vivo mouse retinal imaging: Application of adaptive lens in wavefront sensorless aberration correction
    Bonora, Stefano
    Jian, Yifan
    Pugh, Edward N., Jr.
    Sarunic, Marinko V.
    Zawadzki, Robert J.
    OPTICAL COHERENCE TOMOGRAPHY AND COHERENCE DOMAIN OPTICAL METHODS IN BIOMEDICINE XVIII, 2014, 8934
  • [4] AO-OCT Retinal Imaging with 163-Segment Deformable Mirror
    Finn, Susanna
    Greiner, Cherry
    Doble, Nathan
    Zawadzki, Robert
    Werner, John
    Choi, Stacey
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2013, 54 (15)
  • [5] AO-OCT with reference arm phase shifting for complex conjugate artifact-free imaging of in vivo retinal structures
    Zawadzki, Robert J.
    Kim, Dae Yu
    Jones, Steven M.
    Pilli, Suman
    Olivier, Scot S.
    Werner, John S.
    OPHTHALMIC TECHNOLOGIES XXI, 2011, 7885
  • [6] Quantitative analysis of retinal OCT
    Sonka, Milan
    Abramoff, Michael D.
    MEDICAL IMAGE ANALYSIS, 2016, 33 : 165 - 169
  • [7] S-cone identification using AO-OCT cone structural measurements and support vector machine classifier
    Ji, Qiuzhi
    Bernucci, Marcel T.
    Liu, Yan
    Crowell, James A.
    Miller, Davin J.
    Miller, Donald T.
    OPHTHALMIC TECHNOLOGIES XXXIII, 2023, 12360
  • [8] Performance of a MEMS-based AO-OCT System using Fourier Reconstruction
    Evans, Julia W.
    Zawadzki, Robert J.
    Jones, Steve
    Olivier, Scot
    Werner, John S.
    MEMS ADAPTIVE OPTICS III, 2009, 7209
  • [9] Investigation of retinal microstructure in healthy eyes and dry age-related macular degeneration using a combined AO-OCT-SLO system
    Wells-Gray, Elaine M.
    Choi, Stacey S.
    Ohr, Matthew
    Cebulla, Colleen M.
    Doble, Nathan
    OPTHALMIC TECHNOLOGIES XXVII, 2017, 10045
  • [10] Reducing manual labeling requirements and improved retinal ganglion cell identification in 3D AO-OCT volumes using semi-supervised learning
    Zhou, Mengxi
    Zhang, Yue
    Stacey, Amin Karimi Monsefi
    Choi, Stacey S.
    Doble, Nathan
    Parthasarathy, Srinivasan
    Ramnath, Rajiv
    BIOMEDICAL OPTICS EXPRESS, 2024, 15 (08): : 4540 - 4556