Axillary lymph node recurrence after sentinel lymph node biopsy performed using a combination of indocyanine green fluorescence and the blue dye method in early breast cancer

被引:29
|
作者
Inoue, Tomoo [1 ]
Nishi, Toshio [1 ]
Nakano, Yoshiaki [1 ]
Nishimae, Ayaka [1 ]
Sawai, Yuka [2 ]
Yamasaki, Masaru [3 ]
Inaji, Hideo [1 ]
机构
[1] Kaizuka City Hosp, Dept Breast Surg, 3-10-20 Hori, Kaizuka, Osaka 5970015, Japan
[2] Kaizuka City Hosp, Dept Diagnost Radiol, Kaizuka, Osaka 5970015, Japan
[3] Kaizuka City Hosp, Dept Pathol, Kaizuka, Osaka 5970015, Japan
关键词
Breast cancer; Sentinel lymph node biopsy; Indocyanine green; Fluorescence; Patent blue; CLINICAL-TRIAL; SOCIETY; LOCALIZATION; DISSECTION;
D O I
10.1007/s12282-014-0573-8
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
There is limited information on indocyanine green (ICG) fluorescence and blue dye for detecting sentinel lymph node (SLN) in early breast cancer. A retrospective study was conducted to assess the feasibility of an SLN biopsy using the combination of ICG fluorescence and the blue dye method. Seven hundred and fourteen patients with clinically node-negative breast cancer were included in this study. They underwent SLN biopsy using a combination of ICG fluorescence and the blue dye method from March 2007 to February 2014. The ICG (a fluorescence-emitting source) and patent blue (the blue dye) were injected into the patients' subareolar region. The removed lymph nodes that had ICG fluorescence and/or blue dye uptake were defined as SLNs. The results of the SLN biopsies and follow-up results of patients who underwent SLN biopsy alone were investigated. In 711 out of 714 patients, SLNs were identified by a combination of ICG fluorescence and the blue dye method (detection rate, 99.6 %). The average number of SLNs was 2.4 (range 1-7), and the average number of resected swollen para-SLNs was 0.4 (range 0-5). Ninety-nine patients with an SLN and/or para-SLN involvement during the intraoperative pathological diagnosis underwent axillary lymph node resection (ALND). In addition, two of three patients whose SLN was not identified also underwent ALND. In 46 of 101 patients with an ALND, non-SLN involvement was not found. Follow-up results were analyzed in 464 patients with invasive carcinoma excluding those with ductal carcinoma in situ (n = 148) and those who underwent ALND (n = 101). During the follow-up period (range 4.4-87.7 months; median, 38 months), two patients (0.4 %) developed axillary lymph node recurrence. They were successfully salvaged, and to date, no further locoregional recurrence has been observed. A high rate of SLN detection and low rate of axillary lymph node recurrence were confirmed by an SLN biopsy using a combination of ICG fluorescence and the blue dye method. Therefore, it is suggested that this method may replace the combination of dye and radioisotope methods.
引用
收藏
页码:295 / 300
页数:6
相关论文
共 50 条
  • [1] Axillary lymph node recurrence after sentinel lymph node biopsy performed using a combination of indocyanine green fluorescence and the blue dye method in early breast cancer
    Tomoo Inoue
    Toshio Nishi
    Yoshiaki Nakano
    Ayaka Nishimae
    Yuka Sawai
    Masaru Yamasaki
    Hideo Inaji
    Breast Cancer, 2016, 23 : 295 - 300
  • [2] Indocyanine green fluorescence method for sentinel lymph node biopsy in early breast cancer
    Chen, D.
    Lin, J.
    BREAST, 2017, 32 : S111 - S112
  • [3] Indocyanine green fluorescence method for sentinel lymph node biopsy in breast cancer
    Lin, Joseph
    Lin, Li-Sheng
    Chen, Dar-Ren
    Lin, Kuo-Juei
    Wang, Yu-Fen
    Chang, Yu-Jun
    ASIAN JOURNAL OF SURGERY, 2020, 43 (12) : 1149 - 1153
  • [4] Indocyanine green fluorescence mapping for sentinel lymph node biopsy in early breast cancer
    Pitsinis, Vassilis
    Provenzano, Elena
    Kaklamanis, Loukas
    Wishart, Gordon C.
    Benson, John R.
    SURGICAL ONCOLOGY-OXFORD, 2015, 24 (04): : 375 - 379
  • [5] Sentinel Lymph Node Navigation Surgery Using Combination of Indocyanine Green Fluorescence and Blue Dye for Breast Cancer Patients
    Takahashil, M.
    Hayashidal, T.
    Jinnol, H.
    Kitagawa, Y.
    CANCER RESEARCH, 2011, 71
  • [6] Axillary Recurrence after Sentinel Lymph Node Biopsy for Breast Cancer
    Dauphine, Christine
    Nemtsev, Denis
    Rosing, David
    Vargas, Hernan I.
    AMERICAN SURGEON, 2010, 76 (10) : 1127 - 1129
  • [7] Axillary recurrence after sentinel lymph node biopsy for breast cancer
    Tamaki, Y.
    Tanji, Y.
    Imazato, M.
    Kim, S. J.
    Miyosyi, Y.
    Taguchi, T.
    Ueda, S.
    Ikeda, N.
    Yanagisawa, T.
    Okishiro, K.
    Noguchi, S.
    Proceedings of the XIV World Congress on Breast Diseases, 2006, : 167 - 170
  • [8] Comparison of sentinel lymph node biopsy guided by blue dye with or without indocyanine green in early breast cancer
    Shen, Songjie
    Xu, Qianqian
    Zhou, Yidong
    Mao, Feng
    Guan, Jinghong
    Sun, Qiang
    JOURNAL OF SURGICAL ONCOLOGY, 2018, 117 (08) : 1841 - 1847
  • [9] Investigation for axillary lymph node alone recurrence after sentinel lymph node biopsy without axillary lymph node dissection for breast cancer
    Kurihara, T.
    Takayama, S.
    Ogisawa, K.
    Shiino, S.
    Jimbo, K.
    Asaga, S.
    Kinoshita, T.
    BREAST, 2017, 32 : S116 - S117
  • [10] Evaluation of the benefit of using blue dye in addition to indocyanine green fluorescence for sentinel lymph node biopsy in patients with breast cancer
    Guo, Wenbin
    Zhang, Li
    Ji, Jun
    Gao, Wei
    Liu, Jintao
    Tong, Meng
    WORLD JOURNAL OF SURGICAL ONCOLOGY, 2014, 12 : 1 - 5