An experimental study on the thermal performance of a solar chimney with different dimensional parameters
被引:109
|
作者:
Ghalamchi, Mehrdad
论文数: 0引用数: 0
h-index: 0
机构:
Islamic Azad Univ, Grad Sch Environm & Energy, Dept Energy Engn, Sci & Res Branch, Tehran, IranIslamic Azad Univ, Grad Sch Environm & Energy, Dept Energy Engn, Sci & Res Branch, Tehran, Iran
Ghalamchi, Mehrdad
[1
]
Kasaeian, Alibakhsh
论文数: 0引用数: 0
h-index: 0
机构:
Univ Tehran, Fac New Sci & Technol, Dept Renewable Energies, Tehran, IranIslamic Azad Univ, Grad Sch Environm & Energy, Dept Energy Engn, Sci & Res Branch, Tehran, Iran
Kasaeian, Alibakhsh
[2
]
Ghalamchi, Mehran
论文数: 0引用数: 0
h-index: 0
机构:
Univ Tehran, Fac New Sci & Technol, Dept Renewable Energies, Tehran, IranIslamic Azad Univ, Grad Sch Environm & Energy, Dept Energy Engn, Sci & Res Branch, Tehran, Iran
Ghalamchi, Mehran
[2
]
Mirzahosseini, Alireza Hajiseyed
论文数: 0引用数: 0
h-index: 0
机构:
Islamic Azad Univ, Grad Sch Environm & Energy, Dept Energy Engn, Sci & Res Branch, Tehran, IranIslamic Azad Univ, Grad Sch Environm & Energy, Dept Energy Engn, Sci & Res Branch, Tehran, Iran
Mirzahosseini, Alireza Hajiseyed
[1
]
机构:
[1] Islamic Azad Univ, Grad Sch Environm & Energy, Dept Energy Engn, Sci & Res Branch, Tehran, Iran
[2] Univ Tehran, Fac New Sci & Technol, Dept Renewable Energies, Tehran, Iran
For optimizing solar chimney power plant (SCPP) and also reaching to new experimental data, a pilot setup consisting of a chimney with 3 m height and 3 m collector diameter was constructed. Two main effective parameters including absorber material and geometric dimensions were analyzed using thermal and velocity data. In this paper, the main purpose is obtaining new experimental data in these new dimensions. The obtained data will be utilized in our future after studies for achieving a structural dimensional formulation of SCPPs. In fact, there is no comprehensive formula for achieving a precise relationship between the geometric parameters of the SCPPs. The dimension analyses show that the collector entrance distance of 6 cm has the best performance and the corresponding amounts of the chimney diameter and the chimney height are 10 cm and 3 m, respectively. Also, aluminum absorber has more heat transfer rate than iron one and the maximum fluid temperature difference between the collector and the ambient is 27 degrees C. The maximum air velocity of 1.7 m/s was recorded inside the chimney. In comparison to the chimney with 2 m height, this was about 55.3% higher. (C) 2016 Elsevier Ltd. All rights reserved.
机构:
Fed Univ Rio Grande, Sch Engn, Italia Ave,Km 8, BR-96201900 Rio Grande, BrazilFed Univ Rio Grande, Sch Engn, Italia Ave,Km 8, BR-96201900 Rio Grande, Brazil
Vieira, R. S.
Petry, A. P.
论文数: 0引用数: 0
h-index: 0
机构:
Univ Fed Rio Grande do Sul, Dept Mech Engn, Sarmento Leite St 425, BR-90050170 Porto Alegre, RS, BrazilFed Univ Rio Grande, Sch Engn, Italia Ave,Km 8, BR-96201900 Rio Grande, Brazil
Petry, A. P.
Rocha, L. A. O.
论文数: 0引用数: 0
h-index: 0
机构:
Univ Fed Rio Grande do Sul, Dept Mech Engn, Sarmento Leite St 425, BR-90050170 Porto Alegre, RS, BrazilFed Univ Rio Grande, Sch Engn, Italia Ave,Km 8, BR-96201900 Rio Grande, Brazil
Rocha, L. A. O.
Isoldi, L. A.
论文数: 0引用数: 0
h-index: 0
机构:
Fed Univ Rio Grande, Sch Engn, Italia Ave,Km 8, BR-96201900 Rio Grande, BrazilFed Univ Rio Grande, Sch Engn, Italia Ave,Km 8, BR-96201900 Rio Grande, Brazil
Isoldi, L. A.
dos Santos, E. D.
论文数: 0引用数: 0
h-index: 0
机构:
Fed Univ Rio Grande, Sch Engn, Italia Ave,Km 8, BR-96201900 Rio Grande, BrazilFed Univ Rio Grande, Sch Engn, Italia Ave,Km 8, BR-96201900 Rio Grande, Brazil