In-line control of the lyophilization process. A gentle PAT approach using software sensors

被引:44
作者
Barresi, Antonello A. [1 ]
Velardi, Salvatore A. [1 ]
Pisano, Roberto [1 ]
Rasetto, Valeria [1 ]
Vallan, Alberto [2 ]
Galan, Miquel [3 ]
机构
[1] Politecn Torino, Dip Sci Mat & Ingn Chim, I-10129 Turin, Italy
[2] Politecn Torino, Dip Ingn Elettron, I-10129 Turin, Italy
[3] Telstar Lyo, Terrassa 08226, Spain
来源
INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID | 2009年 / 32卷 / 05期
关键词
Freeze-drying; Freeze-dried product; Measurement; Modelling; Process; Design; Control; MANOMETRIC TEMPERATURE-MEASUREMENT; FREEZE-DRYING PROCESS; TRAY SIDE; VIALS; PHARMACEUTICALS; DESIGN;
D O I
10.1016/j.ijrefrig.2008.10.012
中图分类号
O414.1 [热力学];
学科分类号
摘要
A lyophilization. process is usually only specified in terms of a 'recipe' (shelf temperature and chamber pressure vs. time); according to the recent PAT guidelines issued by FDA, there is the need to develop in-line tools to enable better monitoring and control freeze-drying. in this work an advanced Manometric Temperature Measurement approach, called DPE (Dynamic Parameters Estimation) is first presented, based on a detailed mathematical model. in alternative, the "smart vial" concept is proposed, a Kalman filter based observer allowing an almost continuous monitoring without probes physically inserted into the product. Results obtained for pharmaceutical products in vial in a small industrial prototype equipped with the DPE-based LyoDriver control software, are presented. The software is capable to determine the optimal shelf temperature for primary drying, ensuring the fastest drying time without overcoming the maximum allowable product temperature both in scouting and production cycles. Finally, the two complementary monitoring systems, the DPE and the "smart vial", are combined in an even more robust hybrid control system. (C) 2008 Elsevier Ltd and IIR. All rights reserved.
引用
收藏
页码:1003 / 1014
页数:12
相关论文
共 20 条
[1]  
BARRESI AA, 2007, Patent No. 2007116371
[2]  
BARRESI AA, 2007, P EUR DRYING C AFSIA, P78
[3]  
BARRESI AA, CONTROL OPT IN PRESS
[4]   Monitoring of the primary drying of a lyophilization process in vials [J].
Barresi, Antonello A. ;
Pisano, Roberto ;
Fissore, Davide ;
Rasetto, Valeria ;
Velardi, Salvatore A. ;
Vallan, Alberto ;
Parvis, Marco ;
Galan, Miquel .
CHEMICAL ENGINEERING AND PROCESSING-PROCESS INTENSIFICATION, 2009, 48 (01) :408-423
[5]   Optimization of the freeze-drying cycle: A new model for pressure rise analysis [J].
Chouvenc, P ;
Vessot, S ;
Andrieu, J ;
Vacus, P .
DRYING TECHNOLOGY, 2004, 22 (07) :1577-1601
[6]   In-line control of a freeze-drying process in vials [J].
Fissore, Davide ;
Velardi, Salvatore A. ;
Barresi, Antonello A. .
DRYING TECHNOLOGY, 2008, 26 (06) :685-694
[7]   Freeze-drying of pharmaceuticals in vials on trays: effects of drying chamber wall temperature and tray side on lyophilization performance [J].
Gan, KH ;
Bruttini, R ;
Crosser, OK ;
Liapis, AI .
INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2005, 48 (09) :1675-1687
[8]   Lyophilization in vials on trays: Effects of tray side [J].
Gan, KH ;
Crosser, OK ;
Liapis, AI .
DRYING TECHNOLOGY, 2005, 23 (1-2) :341-363
[9]  
Kalman RE., 1960, NEW APPROACH LINEAR NEW APPROACH LINEAR NEW APPROACH LINEAR NEW APPROACH LINEAR NEW APPROACH LINEAR NEW APPROACH LINEAR NEW APPROACH LINEAR NEW APPROACH LINEAR NEW APPROACH LINEAR NEW APPROACH LINEAR NEW APPROACH LINEAR NEW APPROACH LINEAR NEW APPROACH LINEAR NEW APPROACH LINEAR NEW APPROACH LINEAR NEW APPROACH LINEAR NEW APPROACH LINEAR NEW APPROACH LINEAR NEW APPROACH LINEAR NEW APPROACH LINEAR NEW APPROACH LINEAR NEW APPROACH LINEAR NEW APPROACH LINEAR NEW APPROACH LINEAR N
[10]  
Milton N, 1997, PDA J PHARM SCI TECH, V51, P7