Three-dimensional finite element analysis of buccally cantilevered implant-supported prostheses in a severely resorbed mandible

被引:2
作者
Alom, Ghaith [1 ]
Kwon, Ho-Beom [1 ,2 ]
Lim, Young-Jun [1 ,2 ]
Kim, Myung-Joo [1 ,2 ]
机构
[1] Seoul Natl Univ, Sch Dent, Dept Prosthodont, 101 Daehak Ro, Seoul 03080, South Korea
[2] Seoul Natl Univ, Sch Dent, Dent Res Inst, 101 Daehak Ro, Seoul 03080, South Korea
关键词
Dental prosthesis; Implant-supported; Bone resorption; Dental stress analysis; Finite element analysis; FIXED PARTIAL DENTURES; STRESS-DISTRIBUTION; DENTAL PROSTHESES; CANCELLOUS BONE; SURVIVAL; STRAIN;
D O I
10.4047/jap.2021.13.1.12
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose. The aim of the study was to compare the lingualized implant placement creating a buccal cantilever with prosthetic-driven implant placement exhibiting excessive crown-to-implant ratio. Materials and Methods. Based on patient's CT scan data, two finite element models were created. Both models were composed of the severely resorbed posterior mandible with first premolar and second molar and missing second premolar and first molar, a two-unit prosthesis supported by two implants. The differences were in implants position and crown-to-implant ratio; lingualized implants creating lingually overcontoured prosthesis (Model CP2) and prosthetic-driven implants creating an excessive crown-to-implant ratio (Model PD2). A screw preload of 466.4 N and a buccal occlusal load of 262 N were applied. The contacts between the implant components were set to a frictional contact with a friction coefficient of 0.3. The maximum von Mises stress and strain and maximum equivalent plastic strain were analyzed and compared, as well as volumes of the materials under specified stress and strain ranges. Results. The results revealed that the highest maximum von Mises stress in each model was 1091 MPa for CP2 and 1085 MPa for PD2. In the cortical bone, CP2 showed a lower peak stress and a similar peak strain. Besides, volume calculation confirmed that CP2 presented lower volumes undergoing stress and strain. The stresses in implant components were slightly lower in value in PD2. However, CP2 exhibited a noticeably higher plastic strain. CONCLUSION. Prosthetic-driven implant placement might biomechanically be more advantageous than bone quantity-based implant placement that creates a buccal cantilever.
引用
收藏
页码:12 / 23
页数:12
相关论文
共 51 条
[1]   Comparative analysis of the wear of titanium/titanium and titanium/zirconia interfaces in implant/abutment assemblies after thermocycling and mechanical loading [J].
Almeida, Paulo J. ;
Silva, Cesar L. ;
Alves, Jorge L. ;
Silva, Filipe S. ;
Martins, Ramiro C. ;
Fernandes, Joao Sampaio .
REVISTA PORTUGUESA DE ESTOMATOLOGIA MEDICINA DENTARIA E CIRURGIA MAXILOFACIAL, 2016, 57 (04) :207-214
[2]  
[Anonymous], 2017, J Prosthet Dent, V117, pe1, DOI 10.1016/j.prosdent.2016.12.001
[3]   Number and localization of the implants for the fixed prosthetic reconstructions: On the strain in the anterior maxillary region [J].
Bolukbasi, Nilufer ;
Yeniyol, Sinem .
MEDICAL ENGINEERING & PHYSICS, 2015, 37 (04) :431-445
[4]   The anterior cantilever in the implant-supported screw-retained mandibular prosthesis [J].
Brosky, AE ;
Korioth, TWP ;
Hodges, J .
JOURNAL OF PROSTHETIC DENTISTRY, 2003, 89 (03) :244-249
[5]  
BRUNSKI J B, 1992, Clinical Materials, V10, P153, DOI 10.1016/0267-6605(92)90049-Y
[6]   Deflections of an implant-supported cantilever beam subjected to vertically directed loads. In vitro measurements in three dimensions using an optoelectronic method. II Analysis of methodological errors [J].
Cassel, Bjorn ;
Dan, Lundgren ;
Dan, Karlsson .
CLINICAL ORAL IMPLANTS RESEARCH, 2011, 22 (06) :645-650
[7]   The Effect of the Length and Distribution of Implants for Fixed Prosthetic Reconstructions in the Atrophic Posterior Maxilla: A Finite Element Analysis [J].
Cenkoglu, Brunilda Gashi ;
Balcioglu, Nilufer Bolukbasi ;
Ozdemir, Tayfun ;
Mijiritsky, Eitan .
MATERIALS, 2019, 12 (16)
[8]   Treatment Planning of Implants When 3 Mandibular Posterior Teeth Are Missing: A 3-Dimensional Finite Element Analysis [J].
Chen, Xia-Yun ;
Zhang, Chun-Yuan ;
Nie, Er-Ming ;
Zhang, Mei-chao .
IMPLANT DENTISTRY, 2012, 21 (04) :340-343
[9]  
Coolidge E.D., 1937, J AM DENT ASSOC, V24, P1260, DOI 10.14219/jada.archive.1937.0229
[10]  
DeTolla D H, 2000, J Oral Implantol, V26, P77, DOI 10.1563/1548-1336(2000)026<0077:TROTFE>2.3.CO