Microchip-based ELISA strategy for the detection of low-level disease biomarker in serum

被引:83
作者
Liu, Yun [1 ]
Wang, Huixiang [1 ]
Huang, Jingyu [1 ]
Yang, Jie [1 ]
Liu, Baohong [1 ]
Yang, Pengyuan [1 ]
机构
[1] Fudan Univ, Dept Chem, Inst Biomed Sci, Shanghai 200433, Peoples R China
基金
中国博士后科学基金; 中国国家自然科学基金;
关键词
Microchip; Immunoassays; alpha-Fetoprotein; Electrochemical detection; LINKED-IMMUNOSORBENT-ASSAY; ALPHA-FETOPROTEIN; ENZYME-IMMUNOASSAY; SYSTEM; CHIP; ALPHA-1-FETOPROTEIN; DIAGNOSTICS; AFP;
D O I
10.1016/j.aca.2009.06.048
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A simple and sensitive method has been proposed to determine a trace level of a-fetoprotein (AFP), hepatocellular carcinoma biomarker, using poly(methyl methacrylate) (PMMA) microfluidic chips coupled with electrochemical detection system. The PMMA microchannels have been modified with poly(ethyleneimine) (PEI) containing abundant NH2 groups to covalently immobilize AFP monoclonal antibody. Afterward, the antigen AFP and horseradish peroxidase (HRP)-conjugated AFP antibody can sequentially bind through antigen-anti body specific interaction. Atomic force microscopy (AFM) and confocal fluorescence microscope (CFFM) were utilized to characterize the surface topography and protein immobilization after modification. Coupled with three-electrode electrochemical detection system, the immunochip can perform the detection limit of AFP down to 1 pg mL(-1), and achieve a detectable linear concentration range of 1-500 pg mL(-1) by differential pulse voltammetry (DPV). The on-chip immunoassay platform can not only provide rapid and sensitive detection for target proteins but also be resistant to non-specific adsorption of proteins, which contributes to the detection of low-level protein in real sample. Finally, AFP existing in healthy human serum was detected to demonstrate the utility of the immunochip. The result shows that the proposed approach is feasible and has the potential application in clinical analysis and diagnosis. (C) 2009 Elsevier B.V. All rights reserved.
引用
收藏
页码:77 / 82
页数:6
相关论文
共 23 条
[1]   Surface modification for enhancing antibody binding on polymer-based microfluidic device for enzyme-linked immunosorbent assay [J].
Bai, Yunling ;
Koh, Chee Guan ;
Boreman, Megan ;
Juang, Yi-Je ;
Tang, I-Ching ;
Lee, L. James ;
Yang, Shang-Tian .
LANGMUIR, 2006, 22 (22) :9458-9467
[2]   Plastic ELISA-on-a-chip based on sequential cross-flow chromatography [J].
Cho, JH ;
Han, SM ;
Paek, EH ;
Cho, IH ;
Paek, SH .
ANALYTICAL CHEMISTRY, 2006, 78 (03) :793-800
[3]   Development of a microtiter plate ELISA and a dipstick ELISA for the determination of the organophosphorus insecticide fenthion [J].
Cho, YA ;
Kim, YJ ;
Hammock, BD ;
Lee, YT ;
Lee, HS .
JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 2003, 51 (27) :7854-7860
[4]   Rapid and simple quantitative measurement of α-fetoprotein by combining immunochromatographic strip test and artificial neural network image analysis system [J].
Chuang, L ;
Hwang, JY ;
Chang, HC ;
Chang, FM ;
Jong, SB .
CLINICA CHIMICA ACTA, 2004, 348 (1-2) :87-93
[5]  
CI YX, 1995, ANAL CHIM ACTA, V300, P273
[6]   ENZYME-LINKED IMMUNOADSORBENT ASSAY WITH ELECTROCHEMICAL DETECTION FOR ALPHA-1-ACID GLYCOPROTEIN [J].
DOYLE, MJ ;
HALSALL, HB ;
HEINEMAN, WR .
ANALYTICAL CHEMISTRY, 1984, 56 (13) :2355-2360
[7]   A channel-resolved approach coupled with magnet-captured technique for multianalyte chemiluminescent immunoassay [J].
Fu, Zhifeng ;
Yan, Feng ;
Liu, Hong ;
Lin, Jiehua ;
Ju, Huangxian .
BIOSENSORS & BIOELECTRONICS, 2008, 23 (10) :1422-1428
[8]   Microfluidic immunoassays as rapid saliva-based clinical diagnostics [J].
Herr, Amy E. ;
Hatch, Anson V. ;
Throckmorton, Daniel J. ;
Tran, Huu M. ;
Brennan, James S. ;
Giannobile, William V. ;
Singh, Anup K. .
PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 2007, 104 (13) :5268-5273
[9]   PDMS micro bead cage reactor for the detection of alpha feto protein (AFP) [J].
Jeong, Yongwon ;
Choi, Kihwan ;
Kim, Jinseok ;
Chung, Doo Soo ;
Kim, Byungkyu ;
Kim, Hyeon Cheol ;
Chun, Kukiin .
SENSORS AND ACTUATORS B-CHEMICAL, 2008, 128 (02) :349-358
[10]  
Joos TO, 2000, ELECTROPHORESIS, V21, P2641, DOI 10.1002/1522-2683(20000701)21:13<2641::AID-ELPS2641>3.3.CO