Measurement of serum 17-hydroxyprogesterone using isotope dilution liquid chromatography-tandem mass spectrometry candidate reference method and evaluation of the performance for three routine methods

被引:6
作者
Long, Qichen [1 ]
Zhang, Tianjiao [2 ]
Yan, Ying [2 ]
Zhao, Haijian [2 ]
Zhou, Weiyan [2 ]
Zeng, Jie [2 ]
Li, Shuijun [3 ]
Zhang, Jiangtao [2 ]
Zeng, Qingzhang [1 ]
Zhao, Beibei [4 ]
Zhang, Chuanbao [1 ]
Chen, Wenxiang [1 ]
机构
[1] Chinese Acad Med Sci & Peking Union Med Coll, Chinese Acad Med Sci, Beijing Hosp,Beijing Engn Res Ctr Lab Med, Natl Ctr Gerontol,Inst Geriatr Med,Natl Ctr Clin, 1 Dahua Rd, Beijing 100730, Peoples R China
[2] Chinese Acad Med Sci, Beijing Hosp, Natl Ctr Clin Labs, Natl Ctr Gerontol,Inst Geriatr Med,Beijing Engn R, Beijing, Peoples R China
[3] Shanghai Xuhui Cent Hosp, Cent Lab, Shanghai, Peoples R China
[4] Guangzhou KingMed Diagnost Grp Co Ltd, Guangzhou, Peoples R China
关键词
congenital adrenal hyperplasia; liquid chromatography/tandem mass spectrometry; method evaluation; reference measurement procedure; serum; 17-hydroxyprogesterone; LC-MS/MS; TESTOSTERONE; 17-ALPHA-HYDROXYPROGESTERONE; ANDROSTENEDIONE; QUANTIFICATION; SPECIFICATIONS; DEFICIENCY; CHILDREN;
D O I
10.1515/cclm-2020-0410
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Objectives: Accurate measurements of serum 17-hydroxyprogesterone (17OHP) are essential for diagnosis and treatment monitoring for congenital adrenal hyperplasia patients. The performance of serum 17OHP routine methods remains highly variable that calls for a candidate reference measurement procedure (cRMP) to improve the standardization of serum 17OHP measurements. Methods: Serum samples spiked with internal standards were extractedwith a combination of solid-phase extraction and liquid-liquid extraction. The 17OHP was quantified by the isotope dilution coupled with liquid chromatography/ tandem mass spectrometry (ID-LC/MS/MS) with electrospray ionization in positive ion mode. Nine structural analogs of 17OHP were evaluated for interferences. The precision and analytical recovery were assessed. Twenty native and 40 spiked serum for performance evaluation were measured by the cRMP and two clinical LC/MS routine methods. Results: No apparent interferences were found with the 17OHP measurement. The within-run, between-run, and total precision for our method were 0.4-0.8%, 0.6-2.0%, and 1.0-2.1% for four pooled serum (2.46-102.72 nmol/L), respectively. The recoveries of added 17OHP were 100.0-100.2%. For the performance of two LC/MS routine methods, they showed relative deviation ranges of -22.1 to 1.1% and -6.7 to 12.8%, respectively. Conclusions: We developed and validated a reliable serum 17OHP method using ID-LC/MS/MS. The desirable accuracy and precision of this method enable it to serve as a promising cRMP to improve the standardization for serum17OHP routine measurements.
引用
收藏
页码:523 / 532
页数:10
相关论文
共 50 条
[11]   Evaluation of a bracketing calibration-based isotope dilution liquid chromatography–tandem mass spectrometry candidate reference measurement procedure for 17α-hydroxyprogesterone in human plasma [J].
Qiaoxuan Zhang ;
Lu Zhang ;
Haibiao Lin ;
Zhiliang Cai ;
Jun Yan ;
Qiqin Wang ;
Liqiao Han ;
Jianbing Wang ;
Peifeng Ke ;
Junhua Zhuang ;
Xianzhang Huang .
Analytical and Bioanalytical Chemistry, 2019, 411 :7095-7104
[12]   An isotope dilution liquid chromatography-tandem mass spectrometry candidate reference measurement procedure for aldosterone measurement in human plasma [J].
Qiaoxuan Zhang ;
Liqiao Han ;
Songbai Zheng ;
Fen Ouyang ;
Xiaobin Wu ;
Jun Yan ;
Min Zhan ;
Peifeng Ke ;
Junhua Zhuang ;
Xianzhang Huang .
Analytical and Bioanalytical Chemistry, 2021, 413 :4471-4481
[13]   An isotope dilution liquid chromatography-tandem mass spectrometry candidate reference measurement procedure for aldosterone measurement in human plasma [J].
Zhang, Qiaoxuan ;
Han, Liqiao ;
Zheng, Songbai ;
Ouyang, Fen ;
Wu, Xiaobin ;
Yan, Jun ;
Zhan, Min ;
Ke, Peifeng ;
Zhuang, Junhua ;
Huang, Xianzhang .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2021, 413 (17) :4471-4481
[14]   Liquid chromatography-tandem mass spectrometry analysis of 17-hydroxyprogesterone in dried blood spots revealed matrix effect on immunoassay [J].
Han, Liqiao ;
Tavakoli, Norma P. ;
Morrissey, Mark ;
Spink, David C. ;
Cao, Zhimin .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2019, 411 (02) :395-402
[15]   Endogenous isobaric interference on serum 17 hydroxyprogesterone by liquid chromatography-tandem mass spectrometry methods [J].
Lo, Clara Wai Shan ;
Hoad, Kirsten ;
Loh, Tze Ping ;
van den Berg, Sjoerd ;
Cooke, Brian R. ;
Greaves, Ronda F. ;
Hartmann, Michaela F. ;
Wudy, Stefan A. ;
Ho, Chung Shun .
CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2023, 61 (03) :E64-E66
[16]   An isotope dilution-liquid chromatography-tandem mass spectrometry-based candidate reference measurement procedure for the quantification of 17β-estradiol in human serum and plasma [J].
Ott, Myriam ;
Santner, Tobias ;
Singh, Neeraj ;
Bauland, Friederike ;
Koeppl, Daniel ;
Gaudl, Alexander ;
Geistanger, Andrea ;
Ceglarek, Uta ;
Rauh, Manfred ;
Geletneky, Christian ;
Taibon, Judith .
CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2025,
[17]   Determination of serum cortisol using isotope dilution–liquid chromatography–mass spectrometry as a candidate reference method [J].
Pyong Gil Jung ;
Byungjoo Kim ;
Sang-Ryoul Park ;
Hun-Young So ;
Lian Hua Shi ;
Yongseong Kim .
Analytical and Bioanalytical Chemistry, 2004, 380 :782-788
[18]   Comparison of bracketing calibration and classical calibration curve quantification methods in establishing a candidate reference measurement procedure for human serum 17β-estradiol by isotope dilution liquid chromatography tandem mass spectrometry [J].
Zhang, Qiaoxuan ;
Cai, Zhiliang ;
Liu, Yingyi ;
Lin, Haibiao ;
Wang, Qiqin ;
Yan, Jun ;
Han, Liqiao ;
Wang, Jianbing ;
Ke, Peifeng ;
Zhuang, Junhua ;
Huang, Xianzhang .
MICROCHEMICAL JOURNAL, 2020, 152
[19]   An isotope dilution-liquid chromatography-tandem mass spectrometry-based candidate reference measurement procedure for the quantification of cortisone in human serum and plasma [J].
Ott, Myriam ;
Singh, Neeraj ;
Kubicova, Marie ;
Bauland, Friederike ;
Koeppl, Daniel ;
Gaudl, Alexander ;
Geistanger, Andrea ;
Ceglarek, Uta ;
Rauh, Manfred ;
Geletneky, Christian ;
Taibon, Judith .
CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2025,
[20]   An isotope dilution-liquid chromatography-tandem mass spectrometry-based candidate reference measurement procedure for the quantification of cortisol in human serum and plasma [J].
Ott, Myriam ;
Singh, Neeraj ;
Bauland, Friederike ;
Koeppl, Daniel ;
Kandler, Kerstin ;
Gaudl, Alexander ;
Geistanger, Andrea ;
Ceglarek, Uta ;
Rauh, Manfred ;
Geletneky, Christian ;
Taibon, Judith .
CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2025,