Subject-specific finite element models of long bones: An in vitro evaluation of the overall accuracy

被引:185
作者
Taddei, Fulvia [1 ]
Cristofolini, Luca
Martelli, Saulo
Gill, H. S.
Viceconti, Marco
机构
[1] Ist Ortoped Rizzoli, Lab Tecnol Med, Bologna, Italy
[2] Univ Bologna, Fac Engn, DIEM, Bologna, Italy
[3] Univ Oxford, Nuffield Dept Orthopaed Surg, OOEC, Oxford, England
关键词
finite element modelling; automatic mesh generation; computed tomography; experimental validation; human bones;
D O I
10.1016/j.jbiomech.2005.07.018
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
The determination of the mechanical stresses induced in human bones is of great importance in both research and clinical practice. Since the stresses in bones cannot be measured non-invasively in vivo, the only way to estimate them is through subject-specific finite element modelling. Several methods exist for the automatic generation of these models from CT data, but before bringing them in the clinical practice it is necessary to assess their accuracy in the predictions of the bone stresses. Particular attention should be paid to those regions, like the epiphyseal and metaphyseal parts of long bones, where the automatic methods are typically less accurate. Aim of the present study was to implement a general procedure to automatically generate subject-specific finite element models of bones from CT data and estimate the accuracy of this general procedure by applying it to one real femur. This femur was tested in vitro under five different loading scenarios and the results of these tests were used to verify how the adoption of a simplified two-material homogeneous model would change the accuracy with respect to the density-based inhomogeneous one, with special attention paid to the epiphyseal and metaphyseal proximal regions of the bone. The results showed that the density-based inhomogeneous model predicts with a very good accuracy the measured stresses (R(2) = 0.91, RMSE = 8.6%, peak error = 27%), while the two-material model was less accurate (R(2) = 0.89, RMSE = 9.6%, peak error = 35%). The results showed that it is possible to automatically generate accurate finite element models of bones from CT data and that the strategy of material properties mapping has a significant influence on its accuracy. (c) 2005 Elsevier Ltd. All rights reserved.
引用
收藏
页码:2457 / 2467
页数:11
相关论文
共 43 条
  • [1] In vivo measurements show tensile axial strain in the proximal lateral aspect of the human femur
    Aamodt, A
    Lund-Larsen, J
    Eine, J
    Andersen, E
    Benum, P
    Husby, OS
    [J]. JOURNAL OF ORTHOPAEDIC RESEARCH, 1997, 15 (06) : 927 - 931
  • [2] ARMITAGE P, 1994, STAT METHODS MED RES, P397
  • [3] Hip contact forces and gait patterns from routine activities
    Bergmann, G
    Deuretzbacher, G
    Heller, M
    Graichen, F
    Rohlmann, A
    Strauss, J
    Duda, GN
    [J]. JOURNAL OF BIOMECHANICS, 2001, 34 (07) : 859 - 871
  • [4] A METHOD FOR REGISTRATION OF 3-D SHAPES
    BESL, PJ
    MCKAY, ND
    [J]. IEEE TRANSACTIONS ON PATTERN ANALYSIS AND MACHINE INTELLIGENCE, 1992, 14 (02) : 239 - 256
  • [5] BOISSONNAT JD, 1993, P SOC PHOTO-OPT INS, V1905, P964, DOI 10.1117/12.148710
  • [6] BEAM HARDENING IN X-RAY RECONSTRUCTIVE TOMOGRAPHY
    BROOKS, RA
    DICHIRO, G
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 1976, 21 (03) : 390 - 398
  • [7] A three-dimensional finite element model from computed tomography data: a semi-automated method
    Cattaneo, PM
    Dalstra, M
    Frich, LH
    [J]. PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 2001, 215 (H2) : 203 - 213
  • [8] Cegonino J., 2004, Computer Methods in Biomechanics and Biomedical Engineering, V7, P245, DOI 10.1080/10255840412331307182
  • [9] Finite element analysis of the mechanical behavior of a scapula implanted with a glenoid prosthesis
    Couteau, B
    Mansat, P
    Estivalèzes, É
    Darmana, R
    Mansat, M
    Egan, J
    [J]. CLINICAL BIOMECHANICS, 2001, 16 (07) : 566 - 575
  • [10] DEVELOPMENT AND VALIDATION OF A 3-DIMENSIONAL FINITE-ELEMENT MODEL OF THE PELVIC BONE
    DALSTRA, M
    HUISKES, R
    VANERNING, L
    [J]. JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 1995, 117 (03): : 272 - 278