Indoor air quality in the 21st century: Search for excellence

被引:74
作者
Fanger, PO [1 ]
机构
[1] Tech Univ Denmark, Dept Energy Engn, Ctr Indoor Environm & Energy, DK-2800 Lyngby, Denmark
关键词
productivity; pollution source control; enthalpy; personalized air; individual thermal control;
D O I
10.1034/j.1600-0668.2000.010002068.x
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Field studies demonstrate that there are substantial numbers of dissatisfied people in many buildings, among them those suffering from sick building syndrome (SBS) symptoms, even though existing standards and guidelines are met. The reason is that the requirements specified in these standards are rather low, allowing a substantial group of people to become dissatisfied and to be adversely affected. A paradigm shift from rather mediocre to excellent indoor environments is foreseen in the 21st century. Based on existing information and on new research results, five principles are suggested as elements behind a new philosophy of excellence: 1) better indoor air quality increases productivity and decreases SBS symptoms; 2) unnecessary indoor pollution sources should be avoided; 3) the air should be served cool and dry to the occupants; 4) "personalized air", i.e. a small amount of clean air, should be served gently, close to the breathing zone of each individual; and 5) individual control of the thermal environment should be provided. These principles of excellence are compatible with energy efficiency and sustainability.
引用
收藏
页码:68 / 73
页数:6
相关论文
共 24 条
  • [1] ANDERSSON NH, 1975, HUMAN RESPONSES DRY
  • [2] [Anonymous], 1993, INDOOR AIR, DOI DOI 10.1111/J.1600-0668.1993.00005.X
  • [3] ASHRAE, 1999, Standard 62-1999: Ventilation for acceptable indoor air quality
  • [4] *ASHRAE, 1992, 551992 ASHRAE
  • [5] BERDLUND L, 1989, P IAQ 89 HUM EQ HLTH, P93
  • [6] European indoor air quality audit project in 56 office buildings
    Bluyssen, PM
    Fernandes, ED
    Groes, L
    Clausen, G
    Fanger, PO
    Valbjorn, O
    Bernhard, CA
    Roulet, CA
    [J]. INDOOR AIR-INTERNATIONAL JOURNAL OF INDOOR AIR QUALITY AND CLIMATE, 1996, 6 (04): : 221 - 238
  • [7] CEN, 1998, CR1752 CEN
  • [8] ECA Guidelines for ventilation requirements in buildings, 1992, 11 ECA
  • [9] Impact of temperature and humidity on perception of indoor air quality during immediate and longer whole-body exposures
    Fang, L
    Clausen, G
    Fanger, PO
    [J]. INDOOR AIR-INTERNATIONAL JOURNAL OF INDOOR AIR QUALITY AND CLIMATE, 1998, 8 (04): : 276 - 284
  • [10] Impact of temperature and humidity on chemical and sensory emissions from building materials
    Fang, L
    Clausen, G
    Fanger, PO
    [J]. INDOOR AIR-INTERNATIONAL JOURNAL OF INDOOR AIR QUALITY AND CLIMATE, 1999, 9 (03): : 193 - 201