A novel two-dimensional echocardinarraphic image analysis system using artificial intelligence-learned pattern recognition for rapid automated ejection fraction

被引:66
作者
Cannesson, Maxime
Tanabe, Masaki
Suffoletto, Matthew S.
McNamara, Dennis M.
Madan, Shobhit
Lacomis, Joan M.
Gorcsan, John, III
机构
[1] Univ Pittsburgh, Cardiovasc Inst, Pittsburgh, PA 15213 USA
[2] Univ Pittsburgh, Dept Radiol, Pittsburgh, PA 15213 USA
关键词
D O I
10.1016/j.jacc.2006.08.045
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objectives We sought to test the hypothesis that a novel 2-dimensional echocardiographic image analysis system using artificial intelligence-learned pattern recognition can rapidly and reproducibly calculate ejection fraction (EF). Background Echocardiographic EF by manual tracing is time consuming, and visual assessment is inherently subjective. Methods We studied 218 patients (72 female), including 165 with abnormal left ventricular (LV) function. Auto EF incorporated a database trained on > 10,000 human EF tracings to automatically locate and track the LV endocardium from routine grayscale digital cineloops and calculate EF in 15 s. Auto EF results were independently compared with manually traced biplane Simpson's rule, visual EF, and magnetic resonance imaging (MRI) in a subset. Results Auto EF was possible in 200 (92%) of consecutive patients, of which 77% were completely automated and 23% required manual editing. Auto EF correlated well with manual EF (r = 0.98; 6% limits of agreement) and required less time per patient (48 +/- 26 s vs. 102 21 s; p < 0.01). Auto EF correlated well with visual EF by expert readers (r = 0.96; p < 0.001), but interobserver variability was greater (3.4 +/- 2.9% vs. 9.8 +/- 5.7%, respectively; p < 0.001). Visual EF was less accurate by novice readers (r = 0.82; 19% limits of agreement) and improved with trainee-operated Auto EF (r = 0.96; 7% limits of agreement). Auto EF also correlated with MRI EF (n = 21) (r = 0.95; 12% limits of agreement), but underestimated absolute volumes (r = 0.95; bias of -36 +/- 27 ml overall). Conclusions Auto EF can automatically calculate EF similarly to results by manual biplane Simpson's rule and MRI, with less variability than visual EF, and has clinical potential.
引用
收藏
页码:217 / 226
页数:10
相关论文
共 41 条
[1]   Development and prospective validation of a clinical index to predict survival in ambulatory patients referred for cardiac transplant evaluation [J].
Aaronson, KD ;
Schwartz, JS ;
Chen, TM ;
Wong, KL ;
Goin, JE ;
Mancini, DM .
CIRCULATION, 1997, 95 (12) :2660-2667
[2]   Cardiac resynchronization in chronic heart failure [J].
Abraham, WT ;
Fisher, WG ;
Smith, AL ;
Delurgio, DB ;
Leon, AR ;
Loh, E ;
Kocovic, DZ ;
Packer, M ;
Clavell, AL ;
Hayes, DL ;
Ellestad, M ;
Messenger, J ;
Trupp, RJ ;
Underwood, J ;
Pickering, F ;
Truex, C ;
McAtee, P .
NEW ENGLAND JOURNAL OF MEDICINE, 2002, 346 (24) :1845-1853
[3]   SUPERIORITY OF VISUAL VERSUS COMPUTERIZED ECHOCARDIOGRAPHIC ESTIMATION OF RADIONUCLIDE LEFT-VENTRICULAR EJECTION FRACTION [J].
AMICO, AF ;
LICHTENBERG, GS ;
REISNER, SA ;
STONE, CK ;
SCHWARTZ, RG ;
MELTZER, RS .
AMERICAN HEART JOURNAL, 1989, 118 (06) :1259-1265
[4]   Amiodarone or an implantable cardioverter-defibrillator for congestive heart failure [J].
Bardy, GH ;
Lee, KL ;
Mark, DB ;
Poole, JE ;
Packer, DL ;
Boineau, R ;
Domanski, M ;
Troutman, C ;
Anderson, J ;
Johnson, G ;
McNulty, SE ;
Clapp-Channing, N ;
Davidson-Ray, LD ;
Fraulo, ES ;
Fishbein, DP ;
Luceri, RM ;
Ip, JH .
NEW ENGLAND JOURNAL OF MEDICINE, 2005, 352 (03) :225-237
[5]   Clinical determinants of mortality in patients with angiographically diagnosed ischemic or nonischemic cardiomyopathy [J].
Bart, BA ;
Shaw, LK ;
McCants, CB ;
Fortin, DF ;
Lee, KL ;
Califf, RM ;
OConnor, CM .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1997, 30 (04) :1002-1008
[6]   Comparison of left ventricular ejection fraction and volumes in heart failure by echocardiography, radionuclide ventriculography and cardiovascular magnetic resonance - Are they interchangeable? [J].
Bellenger, NG ;
Burgess, MI ;
Ray, SG ;
Lahiri, A ;
Coats, AJS ;
Cleland, JGF ;
Pennell, DJ .
EUROPEAN HEART JOURNAL, 2000, 21 (16) :1387-1396
[7]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[8]   Cardiac-resynchronization therapy with or without an implantable defibrillator in advanced chronic heart failure [J].
Bristow, MR ;
Saxon, LA ;
Boehmer, J ;
Krueger, S ;
Kass, DA ;
De Marco, T ;
Carson, P ;
DiCarlo, L ;
DeMets, D ;
White, BG ;
DeVries, DW ;
Feldman, AM .
NEW ENGLAND JOURNAL OF MEDICINE, 2004, 350 (21) :2140-2150
[9]   Importance of imaging method over imaging modality in noninvasive determination of left ventricular volumes and ejection fraction - Assessment by two- and three-dimensional echocardiography and magnetic resonance imaging [J].
Chuang, ML ;
Hibberd, MG ;
Salton, CJ ;
Beaudin, RA ;
Riley, MF ;
Parker, RA ;
Douglas, PS ;
Manning, WJ .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2000, 35 (02) :477-484
[10]   The effect of cardiac resynchronization on morbidity and mortality in heart failure [J].
Cleland, JGF ;
Daubert, J ;
Erdmann, E ;
Freemantle, N ;
Gras, D ;
Kappenberger, L ;
Tavazzi, L ;
Cleland, JGF ;
Daubert, JC ;
Erdmann, E ;
Gras, D ;
Kappenberger, L ;
Klein, W ;
Tavazzi, L ;
Poole-Wilson, PA ;
Rydén, L ;
Wedel, H ;
Wellens, HJJ ;
Uretsky, B ;
Thygesen, K ;
Böcker, D ;
Marijianowski, MMH ;
Freemantle, N ;
Calvert, MJ ;
Christ, G ;
Fruhwald, F ;
Hofmann, R ;
Krypta, A ;
Leisch, F ;
Pacher, R ;
Rauscha, F ;
Tavernier, R ;
Thomsen, PEB ;
Boesgaard, S ;
Eiskjær, H ;
Esperen, GT ;
Haarbo, J ;
Hagemann, A ;
Korup, E ;
Moller, M ;
Mortensen, P ;
Sogaard, P ;
Vesterlund, T ;
Huikuri, H ;
Niemelä, KI ;
Toivonen, L ;
Bauer, F ;
Cohen-Solal, A ;
Crocq, C ;
Djiane, P .
NEW ENGLAND JOURNAL OF MEDICINE, 2005, 352 (15) :1539-1549