Ambulatory measurement of arm orientation

被引:245
作者
Luinge, H. J.
Veltink, P. H.
Baten, C. T. M.
机构
[1] Univ Twente, Inst Biomed Engn, Signals & Syst Grp, Dept Elect Engn, NL-7500 AE Enschede, Netherlands
[2] Roessingh Res & Dev, Enschede, Netherlands
[3] Xsens Technol Bv, Enschede, Netherlands
关键词
upper-extremities; elbow; kinematics; inertial sensors; gyroscope; accelerometer;
D O I
10.1016/j.jbiomech.2005.11.011
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
In order to evaluate the impact of neuromuscular disorders affecting the upper extremities, the functional use of the arm need to be evaluated during daily activities. A system suitable for measuring arm kinematics should be ambulatory and not interfere with activities of daily living. A measurement system based on miniature accelerometers and gyroscopes is adequate because the sensors are small and do not suffer from line of sight problems. A disadvantage of such sensors is the cumulative drift around the vertical and the problems with aligning the sensor with the segment. A method that uses constraints in the elbow to measure the orientation of the lower arm with respect to the upper arm is described. This requires a calibration method to determine the exact orientation of each of the sensors with respect to the segment. Some preliminary measurements were analyzed and they indicated a strong reduction in orientation error around the vertical. It seemed that the accuracy of the method is limited by the accuracy of the sensor to segment calibration. (c) 2005 Elsevier Ltd. All rights reserved.
引用
收藏
页码:78 / 85
页数:8
相关论文
共 22 条
  • [11] Hoff JI, 1999, MOVEMENT DISORD, V14, P737, DOI 10.1002/1531-8257(199909)14:5<737::AID-MDS1005>3.0.CO
  • [12] 2-A
  • [13] Body position can be monitored in 3D using miniature accelerometers and earth-magnetic field sensors
    Kemp, B
    Janssen, AJMW
    van der Kamp, B
    [J]. ELECTROMYOGRAPHY AND MOTOR CONTROL-ELECTROENCEPHALOGRAPHY AND CLINICAL NEUROPHYSIOLOGY, 1998, 109 (06): : 484 - 488
  • [14] Measuring orientation of human body segments using miniature gyroscopes and accelerometers
    Luinge, HJ
    Veltink, PH
    [J]. MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 2005, 43 (02) : 273 - 282
  • [15] Inclination measurement of human movement using a 3-D accelerometer with autocalibration
    Luinge, HJ
    Veltink, PH
    [J]. IEEE TRANSACTIONS ON NEURAL SYSTEMS AND REHABILITATION ENGINEERING, 2004, 12 (01) : 112 - 121
  • [16] Assessment of the accuracy of a human arm model with seven degrees of freedom
    Prokopenko, RA
    Frolov, AA
    Biryukova, EV
    Roby-Brami, A
    [J]. JOURNAL OF BIOMECHANICS, 2001, 34 (02) : 177 - 185
  • [17] Compensation of magnetic disturbances improves inertial and magnetic sensing of human body segment orientation
    Roetenberg, D
    Luinge, HJ
    Baten, CTM
    Veltink, PH
    [J]. IEEE TRANSACTIONS ON NEURAL SYSTEMS AND REHABILITATION ENGINEERING, 2005, 13 (03) : 395 - 405
  • [18] Coordination of multi-joint arm movements in cerebellar ataxia: analysis of hand and angular kinematics
    Topka, H
    Konczak, J
    Dichgans, J
    [J]. EXPERIMENTAL BRAIN RESEARCH, 1998, 119 (04) : 483 - 492
  • [19] Objective measurement of functional upper-extremity movement using accelerometer recordings transformed with a threshold filter
    Uswatte, G
    Miltner, WHR
    Foo, B
    Varma, M
    Moran, S
    Taub, E
    [J]. STROKE, 2000, 31 (03) : 662 - 667
  • [20] 3-DIMENSIONAL RECORDING AND DESCRIPTION OF MOTIONS OF THE SHOULDER MECHANISM
    VANDERHELM, FCT
    PRONK, GM
    [J]. JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 1995, 117 (01): : 27 - 40