Ultrasensitive electrochemical sensor for mercury (II) based on target-induced structure-switching DNA

被引:157
作者
Wu, Danhong [1 ]
Zhang, Qing [1 ]
Chu, Xia [1 ]
Wang, Haibo [1 ]
Shen, Guoli [1 ]
Yu, Ruqin [1 ]
机构
[1] Hunan Univ, Coll Chem & Chem Engn, State Key Lab Chemobiosensing & Chemometr, Changsha 410082, Hunan, Peoples R China
关键词
Mercury; Electrochemical sensor; Structure-switching DNA; Differential pulse voltammetry; SURFACE HYBRIDIZATION ASSAY; AQUEOUS-SOLUTION; HG-II; COLORIMETRIC DETECTION; SELECTIVE DETECTION; GOLD NANOPARTICLES; SIGNALING APTAMERS; FLUORESCENT SENSOR; PROBES; IONS;
D O I
10.1016/j.bios.2009.09.017
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
A novel electrochemical sensor has been developed for sensitive and selective detection of mercury (II) based on target-induced structure-switching DNA. A 33-mer oligonucleotide 1 with five self-complementary base pairs separated by seven thymine-thymine mismatches was first immobilized on the electrode via self-assembly of the terminal thiol moiety and then hybridized with a ferrocene-tagged oligonucleotide 2, leading to a high redox current. in the presence of Hg2+, mercury-mediated base pairs (T-Hg2+-T) induced the folding of the oligonucleotide 1 into a hairpin structure, resulting in the release of the ferrocene-tagged oligonucleotide 2 from the electrode surface with a substantially decreased redox current. The response characteristics of the sensor were thoroughly investigated using cyclic voltammetry (CV), differential pulse voltammetry (DPV) and electrochemical impedance spectroscopy (EIS). The effect of the reaction temperature on the response of the sensor was also studied in detail. The results revealed that the sensor showed sensitive response to Hg2+ in a concentration range from 0.1 nM to 5 mu M with a detection limit of 0.06 nM. In addition, this strategy afforded exquisite selectivity for Hg2+ against other environmentally related metal ions, which was superior to that of previous anodic stripping voltammetry (ASV)-based techniques. The excellent sensitivity and selectivity signified the potential of the sensor for Hg2+ detection in real environmental samples. (C) 2009 Elsevier B.V. All rights reserved.
引用
收藏
页码:1025 / 1031
页数:7
相关论文
共 50 条
  • [21] Signal-on electrochemical detection of DNA methylation based on the target-induced conformational change of a DNA probe and exonuclease III-assisted target recycling
    Feng, Qiumei
    Qin, Li
    Wang, Mengying
    Wang, Po
    BIOSENSORS & BIOELECTRONICS, 2020, 149
  • [22] Graphene-Gold Nanoparticle-modified Electrochemical Sensor for Detection of Kanamycin Based on Target-induced Aptamer Displacement
    Zheng Jingyi
    Feng Rongrong
    He Caimei
    Li Xiaoxia
    CHEMICAL RESEARCH IN CHINESE UNIVERSITIES, 2018, 34 (06) : 952 - 958
  • [23] Functionalized gold nanoparticles/reduced graphene oxide nanocomposites for ultrasensitive electrochemical sensing of mercury ions based on thymine-mercury-thymine structure
    Wang, Nan
    Lin, Meng
    Dai, Hongxiu
    Ma, Houyi
    BIOSENSORS & BIOELECTRONICS, 2016, 79 : 320 - 326
  • [24] A universal converting strategy based on target-induced DNA nanoprobe conformational change for lead (II) ion assay
    Yang, Zhehan
    Wu, Hong
    Yi, Xingchen
    Tang, Jiajia
    Yun, Wen
    Han, Wenbo
    Chen, Xingguang
    BIOSENSORS & BIOELECTRONICS, 2019, 144
  • [25] Target-Induced DNA Mismatch for One-Spot Simultaneous Electrochemical Detection of Multiple Heavy Metals Based on the Amplification of DNA Concatemers
    Liu, Guangpeng
    Wang, Haijun
    Yuan, Yali
    Wang, Jianli
    JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 2017, 164 (04) : B81 - B85
  • [26] A Novel Electrochemical Aptasensor for Carcinoembryonic Antigen Detection Based on Target-induced Bridge Assembly
    Taghdisi, Seyed Mohammad
    Danesh, Noor Mohammad
    Ramezani, Mohammad
    Emrani, Ahmad Sarreshtehdar
    Abnous, Khalil
    ELECTROANALYSIS, 2018, 30 (08) : 1726 - 1731
  • [27] A Reusable Electrochemical Aptasensor for the Sensitive Detection of Pb(II) with an Electrodeposited AuNP-Modified Electrode based on the Formation of a Target-Induced G-Quadruplex
    Zhao, Guo
    Li, Cong
    Wang, Xiaochan
    Liu, Gang
    Nguyen Thi Dieu Thuy
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2021, 16 (01): : 1 - 14
  • [28] Colorimetric and visual mercury(II) assay based on target-induced cyclic enzymatic amplification, thymine-Hg(II)-thymine interaction, and aggregation of gold nanoparticles
    Song, Xiaolei
    Wang, Yu
    Liu, Su
    Zhang, Xue
    Wa, Haiwang
    Wa, Jingfeng
    Huang, Jiadong
    MICROCHIMICA ACTA, 2019, 186 (02)
  • [29] An ultrasensitive electrochemical mercury(II) ion biosensor based on a glassy carbon electrode modified with multi-walled carbon nanotubes and gold nanoparticles
    Lu, Xiaocui
    Dong, Xiao
    Zhang, Keying
    Zhang, Yuzhong
    ANALYTICAL METHODS, 2012, 4 (10) : 3326 - 3331
  • [30] A novel label-free hypochlorite amperometric sensor based on target-induced oxidation of benzeneboronic acid pinacol ester
    Guo, Danzhao
    Wu, Shuwen
    Xu, Xuechao
    Niu, Xiangheng
    Li, Xin
    Li, Zhenjiang
    Pan, Jianming
    CHEMICAL ENGINEERING JOURNAL, 2019, 373 : 1 - 7