Heat removal analysis in the AP1000 reactor's refuelling process

被引:0
作者
Isnaini, Muh Darwis [1 ]
Subekti, M. [1 ]
机构
[1] BATAN, Ctr Nucl Reactor Technol & Safety, PUSPIPTEK Area Bldg 80 Serpong, Tangerang Selatan 15310, Indonesia
来源
SYMPOSIUM OF EMERGING NUCLEAR TECHNOLOGY AND ENGINEERING NOVELTY (SENTEN 2018) | 2019年 / 1198卷
关键词
D O I
10.1088/1742-6596/1198/2/022066
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
A study has been conducted to find out how much heat removal in the refueling process in AP1000 reactor. The background of this research is, operation at a Nuclear Power Plant is strongly tied to periodical fuel replacement to guarantee future operations. The replacement of fuel assembly can be done by one-third of core or a half of core refueling. After the reactor shutdown, the spent fuel assemblies still generate decay heat that must be removed to prevent from fuel damage cause of heat buildup. The process of heat removal can be done by natural and forced convection modes. The purpose of this study was to obtain the cooling times after shutdown so that the fuel assembly can be transferred to the spent fuel storage pool (SFSP) with natural convection mode, and how minimum flow rate was required for cooling the 7 days spent fuel assembly by forced convection cooling in the SFSP. The requirement in the cooling was no boiling occurred in the channel. The calculation was carried out by assuming the inlet coolant temperature of 30 degrees C and by using COOLOD-N2 code. The calculation results showed that for the one-third of core refueling and for cooling with natural convection, it took 21 days after shutdown, the new spent fuel assemblies could be transferred to SFSP, while for the forced convection cooling required minimum flow rate of 15 kg/s in the SFSP. The calculation result on the hot channel showed the outlet coolant temperature of 101.88 degrees C, the maximum temperature of the outer cladding and the center fuel meat of 104.63 degrees C and 105.21 degrees C, respectively. As for a half of core refueling and for cooling with natural convection, it took 42 days after shutdown, the new spent fuel assemblies could be transferred to SFSP, while for the forced convection cooling required minimum flow rate of 25 kg/s in the SFSP. Calculations on the hottest channel showed the outlet coolant temperature of 90.54 degrees C, the maximum temperature of outer cladding and the center fuel meat of 93.16 degrees C and 93.75 degrees C, respectively.
引用
收藏
页数:8
相关论文
共 11 条
[1]   Thermal hydraulic analyses of JRR-3: Code-to-code comparison of COOLOD-N2 and TMAP [J].
Albati, Mohammad A. ;
AL-Yahia, Omar S. ;
Park, Jonghark ;
Chae, Heetaek ;
Jo, Daeseong .
PROGRESS IN NUCLEAR ENERGY, 2014, 71 :1-8
[2]  
Bhowmik N, 2014, IRAN J APPL ANIM SCI, V4, P89
[3]   Determining Coolant Flow Rate Distribution In The Fuel-Modified TRIGA Plate Reactor [J].
Hastuti, Endiah Puji ;
Widodo, Surip ;
Isnaini, M. Darwis ;
Rina, Geni S. ;
Syaiful, B. .
INTERNATIONAL CONFERENCE ON NUCLEAR ENERGY TECHNOLOGIES AND SCIENCES (ICONETS 2017), 2018, 962
[4]  
Isnaini M D, 2015, TRI DASA MEGA, V17, P79
[5]  
Isnaini M D, 2013, TRI DASA MEGA, V16, P159
[6]  
Isnaini MD, 2016, J PENG ENERGI NUKL, V18, P31
[7]   Development of thermal hydraulic and margin analysis code for steady state forced and natural convective cooling of plate type fuel research reactors [J].
Jo, Daeseong ;
Park, Jonghark ;
Chae, Heetaek .
PROGRESS IN NUCLEAR ENERGY, 2014, 71 :39-51
[8]  
Subekti M, 2013, TRI DASA MEGA, V15, P67
[9]   Neutronics and thermal hydraulic analysis of TRIGA Mark II reactor using MCNPX and COOLOD-N2 computer code [J].
Tiyapun, K. ;
Wetchagarun, S. .
INTERNATIONAL NUCLEAR SCIENCE AND TECHNOLOGY CONFERENCE 2016, 2017, 860
[10]  
Todreas N E, 1993, NUCL SYSTEM, P64