Wireless Micropower Instrumentation for Multimodal Acquisition of Electrical and Chemical Neural Activity

被引:34
作者
Mollazadeh, Mohsen [1 ]
Murari, Kartikeya [1 ]
Cauwenberghs, Gert [2 ]
Thakor, Nitish V. [1 ]
机构
[1] Johns Hopkins Univ, Dept Biomed Engn, Baltimore, MD 21205 USA
[2] Univ Calif San Diego, Jacobs Sch Engn, Dept Bioengn, La Jolla, CA 92093 USA
关键词
Brain-computer interface (BCI); biopotential amplifier; chemical sensing; digital telemetry; electrocorticogram (ECOG); electroencephalogram (EEG); inductive coupling; micropower instrumentation; neural interface; neurotransmitters; potentiostat; POTENTIOSTAT ARRAY; CMOS; AMPLIFIER; TELEMETRY; DEVICES; COILS;
D O I
10.1109/TBCAS.2009.2031877
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The intricate coupling between electrical and chemical activity in neural pathways of the central nervous system, and the implication of this coupling in neuropathologies, such as Parkinson's disease, motivates simultaneous monitoring of neurochemical and neuropotential signals. However, to date, neurochemical sensing has been lacking in integrated clinical instrumentation as well as in brain-computer interfaces (BCI). Here, we present an integrated system capable of continuous acquisition of data modalities in awake, behaving subjects. It features one channel each of a configurable neuropotential and a neurochemical acquisition system. The electrophysiological channel is comprised of a 40-dB gain, fully differential amplifier with tunable bandwidth from 140 Hz to 8.2 kHz. The amplifier offers input-referred noise below 2 mu V-rms for all bandwidth settings. The neurochemical module features a picoampere sensitivity potentiostat with a dynamic range spanning six decades from picoamperes to microamperes. Both systems have independent on-chip, configurable Delta Sigma analog-to-digital converters (ADCs) with programmable digital gain and resolution. The system was also interfaced to a wireless power harvesting and telemetry module capable of powering up the circuits, providing clocks for ADC operation, and telemetering out the data at up to 32 kb/s over 3.5 cm with a bit-error rate of less than 10(-5). Characterization and experimental results from the electrophysiological and neurochemical modules as well as the full system are presented.
引用
收藏
页码:388 / 397
页数:10
相关论文
共 43 条
[21]   NITRIC-OXIDE RELEASE FROM A SINGLE CELL MEASURED INSITU BY A PORPHYRINIC-BASED MICROSENSOR [J].
MALINSKI, T ;
TAHA, Z .
NATURE, 1992, 358 (6388) :676-678
[22]   A CMOS IC for portable EEG acquisition systems [J].
Martins, R ;
Selberherr, S ;
Vaz, FA .
IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 1998, 47 (05) :1191-1196
[23]   A fully integrated neural recording amplifier with DC input stabilization [J].
Mohseni, P ;
Najafi, K .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2004, 51 (05) :832-837
[24]   Micropower CMOS Integrated Low-Noise Amplification, Filtering, and Digitization of Multimodal Neuropotentials [J].
Mollazadeh, Mohsen ;
Murari, Kartikeya ;
Cauwenberghs, Gert ;
Thakor, Nitish .
IEEE TRANSACTIONS ON BIOMEDICAL CIRCUITS AND SYSTEMS, 2009, 3 (01) :1-10
[25]   Wireless Multichannel Acquisition of Neuropotentials [J].
Mollazadeh, Mohsen ;
Murari, Kartikeya ;
Schwerdt, Helen ;
Wang, Xing ;
Thakor, Nitish ;
Cauwenberghs, Gert .
2008 IEEE BIOMEDICAL CIRCUITS AND SYSTEMS CONFERENCE - INTELLIGENT BIOMEDICAL SYSTEMS (BIOCAS), 2008, :49-+
[26]   Integrated potentiostat for neurotransmitter sensing [J].
Murari, K ;
Stanacevic, M ;
Cauwenberghs, G ;
Thakor, NV .
IEEE ENGINEERING IN MEDICINE AND BIOLOGY MAGAZINE, 2005, 24 (06) :23-29
[27]  
MURARI K, 2008, SPIE, V7035
[28]  
Murro A., 2003, Epilepsia, V44, P326
[29]   An integrated system for multichannel neuronal recording with spike/LFP separation, integrated A/D conversion and threshold detection [J].
Perelman, Yevgeny ;
Ginosar, Ran .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2007, 54 (01) :130-137
[30]  
ROHAM M, 2009, IEEE J SOLI IN PRESS, V44