Wireless Micropower Instrumentation for Multimodal Acquisition of Electrical and Chemical Neural Activity

被引:34
作者
Mollazadeh, Mohsen [1 ]
Murari, Kartikeya [1 ]
Cauwenberghs, Gert [2 ]
Thakor, Nitish V. [1 ]
机构
[1] Johns Hopkins Univ, Dept Biomed Engn, Baltimore, MD 21205 USA
[2] Univ Calif San Diego, Jacobs Sch Engn, Dept Bioengn, La Jolla, CA 92093 USA
关键词
Brain-computer interface (BCI); biopotential amplifier; chemical sensing; digital telemetry; electrocorticogram (ECOG); electroencephalogram (EEG); inductive coupling; micropower instrumentation; neural interface; neurotransmitters; potentiostat; POTENTIOSTAT ARRAY; CMOS; AMPLIFIER; TELEMETRY; DEVICES; COILS;
D O I
10.1109/TBCAS.2009.2031877
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The intricate coupling between electrical and chemical activity in neural pathways of the central nervous system, and the implication of this coupling in neuropathologies, such as Parkinson's disease, motivates simultaneous monitoring of neurochemical and neuropotential signals. However, to date, neurochemical sensing has been lacking in integrated clinical instrumentation as well as in brain-computer interfaces (BCI). Here, we present an integrated system capable of continuous acquisition of data modalities in awake, behaving subjects. It features one channel each of a configurable neuropotential and a neurochemical acquisition system. The electrophysiological channel is comprised of a 40-dB gain, fully differential amplifier with tunable bandwidth from 140 Hz to 8.2 kHz. The amplifier offers input-referred noise below 2 mu V-rms for all bandwidth settings. The neurochemical module features a picoampere sensitivity potentiostat with a dynamic range spanning six decades from picoamperes to microamperes. Both systems have independent on-chip, configurable Delta Sigma analog-to-digital converters (ADCs) with programmable digital gain and resolution. The system was also interfaced to a wireless power harvesting and telemetry module capable of powering up the circuits, providing clocks for ADC operation, and telemetering out the data at up to 32 kb/s over 3.5 cm with a bit-error rate of less than 10(-5). Characterization and experimental results from the electrophysiological and neurochemical modules as well as the full system are presented.
引用
收藏
页码:388 / 397
页数:10
相关论文
共 43 条
[1]   Selecting the signals for a brain-machine interface [J].
Andersen, RA ;
Musallam, S ;
Pesaran, B .
CURRENT OPINION IN NEUROBIOLOGY, 2004, 14 (06) :720-726
[2]  
[Anonymous], 2007, BRAIN COMPUTER INTER
[3]  
[Anonymous], 1998, Medical Instrumentation: Application and Design
[4]  
AZIZ J, 2007, P IEEE INT SOL STAT, P160
[5]   Liquid chromatography in the analysis of neurotransmitters and alkaloids [J].
Baranowska, I ;
Zydron, M .
JOURNAL OF CHROMATOGRAPHIC SCIENCE, 2002, 40 (04) :224-228
[6]  
Bear M. F., 2016, Neuroscience: Exploring the Brain
[7]   NANOGRAM NITRITE AND NITRATE DETERMINATION IN ENVIRONMENTAL AND BIOLOGICAL-MATERIALS BY VANADIUM(III) REDUCTION WITH CHEMI-LUMINESCENCE DETECTION [J].
BRAMAN, RS ;
HENDRIX, SA .
ANALYTICAL CHEMISTRY, 1989, 61 (24) :2715-2718
[8]  
Chae M., 2008, 2008 IEEE International Solid State Circuits Conference, ISSCC, P146
[9]   A 2 μW 100 nV/rtHz chopper-stabilized instrumentation amplifier for chronic measurement of neural field potentials [J].
Denison, Tim ;
Consoer, Kelly ;
Santa, Wesley ;
Avestruz, Al-Thaddeus ;
Cooley, John ;
Kelly, Andy .
IEEE JOURNAL OF SOLID-STATE CIRCUITS, 2007, 42 (12) :2934-2945
[10]   A MONOLITHIC SIGNAL PROCESSOR FOR A NEUROPHYSIOLOGICAL TELEMETRY SYSTEM [J].
DORMAN, MG ;
PRISBE, MA ;
MEINDL, JD .
IEEE JOURNAL OF SOLID-STATE CIRCUITS, 1985, 20 (06) :1185-1193