Visual quality after implantation of trifocal intraocular lenses in highly myopic eyes with different axial lengths

被引:8
作者
Liu, Hui [1 ,2 ,3 ]
Li, Fang-Fang [1 ]
Xia, Hai-Jun [1 ]
Zhou, Jin [1 ,3 ]
机构
[1] Chengdu Aier Eye Hosp, Dept Ophthalmol, Chengdu 610041, Sichuan, Peoples R China
[2] Chongqing Aier Eye Hosp, Dept Ophthalmol, Chongqing 400020, Peoples R China
[3] Cent South Univ, Dept Ophthalmol, Aier Sch Ophthalmol, Changsha 410012, Hunan, Peoples R China
关键词
cataract; trifocal IOL; OQAS; high myopia; OPTICAL-QUALITY; PERFORMANCE; CATARACT; OUTCOMES; ABERRATIONS; SIZE;
D O I
10.18240/ijo.2021.03.06
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
AIM: To analyze postoperative clinical results after implantation of trifocal intraocular lenses (IOLs) in highly myopic eyes with different axial lengths (ALs). METHODS: This retrospective study describes 61 eyes of 44 patients that were implanted with trifocal diffractive IOLs (AT LISA tri 839MP). Twenty-one eyes (15 patients) were included in the AL<26 mm group, 19 eyes (13 patients) in the AL >= 26 mm and <28 mm group, and 21 eyes (16 patients) in the AL >= 28 mm group. Postoperative outcomes, including corrected and uncorrected distance visual acuity (UDVA), intermediate and near visual acuity at 167 cd/m(2) luminance, depth of focus at 85 cd/m(2) luminance, and objective optical quality parameters assessed using the Optical Quality Analysis System (OQAS), were compared among the groups at 3mo. RESULTS: There were no significant differences in the mean UDVA, uncorrected intermediate visual acuity, uncorrected near visual acuity, corrected distance visual acuity, distance-corrected intermediate visual acuity, and distance-corrected near visual acuity (DCNVA) among the three groups (P>0.05). Better near and intermediate visual acuity (from -1.5 D to -3.0 D) were noted on the defocus curve of the AL<26 mm group (P<0.01 vs AL >= 28 mm group). Significantly higher objective scatter index (OSI) values and lower modulation transfer function (MTF) cut-off values, Strehl ratio (SR), and OQAS values (OVs) were observed in the AL >= 28 mm group (P<0.01 vs AL<26 mm group). All OQAS parameters had statistically significant correlations with DCNVA and visual acuity at the vergence of -2.5 D (P<0.05 to P<0.01). CONCLUSION: Implantation of trifocal IOLs provides good short-term visual and refractive outcomes in highly myopic eyes with different ALs. However, the near vision decreases in the extremely myopic eyes at lower luminance, which is associated with the lower objective optical quality in these eyes.
引用
收藏
页码:371 / 377
页数:7
相关论文
共 30 条
[1]   Intraocular lens power calculation for eyes with an axial length greater than 26.0 mm: Comparison of formulas and methods [J].
Abulafia, Adi ;
Barrett, Graham D. ;
Rotenberg, Michael ;
Kleinmann, Guy ;
Levy, Adi ;
Reitblat, Olga ;
Koch, Douglas D. ;
Wang, Li ;
Assia, Ehud I. .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2015, 41 (03) :548-556
[2]   Evaluation and comparison of the new swept source OCT-based IOLMaster 700 with the IOLMaster 500 [J].
Akman, Ahmet ;
Asena, Leyla ;
Gungor, Sirel Gur .
BRITISH JOURNAL OF OPHTHALMOLOGY, 2016, 100 (09) :1201-1205
[3]   Comparison of a New Refractive Multifocal Intraocular Lens with an Inferior Segmental Near Add and a Diffractive Multifocal Intraocular Lens [J].
Alio, Jorge L. ;
Plaza-Puche, Ana B. ;
Javaloy, Jaime ;
Jose Ayala, Maria ;
Moreno, Luis J. ;
Pinero, David P. .
OPHTHALMOLOGY, 2012, 119 (03) :555-563
[4]   Comparison of the Visual and Intraocular Optical Performance of a Refractive Multifocal IOL With Rotational Asymmetry and an Apodized Diffractive Multifocal IOL [J].
Alio, Jorge L. ;
Plaza-Puche, Ana B. ;
Javaloy, Jaime ;
Ayala, Maria Jose .
JOURNAL OF REFRACTIVE SURGERY, 2012, 28 (02) :100-U84
[5]   Accuracy of Intraocular Lens Calculations Using the IOLMaster in Eyes with Long Axial Length and a Comparison of Various Formulas [J].
Bang, Stacy ;
Edell, Erica ;
Yu, Qilu ;
Pratzer, Kim ;
Stark, Walter .
OPHTHALMOLOGY, 2011, 118 (03) :503-506
[6]  
Bianchi German Roberto, 2020, Med Hypothesis Discov Innov Ophthalmol, V9, P38
[7]   Objective and subjective visual quality after implantation of all optic zone diffractive multifocal intraocular lenses: a prospective, case-control observational study [J].
Chen, Tianyu ;
Yu, Fang ;
Lin, Huayou ;
Zhao, Yinying ;
Chang, Pingjun ;
Lin, Lei ;
Chen, Qi ;
Zheng, Qian ;
Zhao, Yun-e ;
Lu, Fan ;
Li, Jin .
BRITISH JOURNAL OF OPHTHALMOLOGY, 2016, 100 (11) :1530-1535
[8]   The Distinct Biometric Features of High Myopia Compared to Moderate Myopia [J].
Chung, Hye Jin ;
Park, Chan Kee .
CURRENT EYE RESEARCH, 2016, 41 (12) :1580-1583
[9]   Comparison of the retinal image quality with a Hartmann-Shack wavefront sensor and a double-pass instrument [J].
Díaz-Doutón, F ;
Benito, A ;
Pujol, J ;
Arjona, M ;
Güell, JL ;
Artal, P .
INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2006, 47 (04) :1710-1716
[10]   Optical Quality Analysis System:: Instrument for objective clinical evaluation of ocular optical quality [J].
Güell, JL ;
Pujol, J ;
Arjona, M ;
Diaz-Douton, F ;
Artal, P .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2004, 30 (07) :1598-1599