Evaluation of a computer aided detection system for lung nodules with ground glass opacity component on multidetector-row CT

被引:10
作者
Beigelman-Aubry, C. [1 ]
Hill, C. [1 ]
Boulanger, X. [1 ]
Brun, A. L. [1 ]
Leclercq, D. [1 ]
Golmard, J. L. [2 ,3 ]
Grenier, P. A. [1 ]
Lucidarme, O. [1 ]
机构
[1] Univ Paris 06, Serv Radiol, Hop La Pitie Salpetriere, AP HP, F-75651 Paris 13, France
[2] Univ Paris 06, Unite Rech Clin, Hop La Pitie Salpetriere, AP HP, F-75651 Paris 13, France
[3] Univ Paris 06, INSERM, Hop La Pitie Salpetriere, AP HP,U678, F-75651 Paris 13, France
来源
JOURNAL DE RADIOLOGIE | 2009年 / 90卷 / 12期
关键词
Subsolid lung nodule; CT; Computer-aided detection; THIN-SECTION CT; PULMONARY NODULES; INITIAL-EXPERIENCE; CM; PERFORMANCE; RADIOLOGISTS; DIAGNOSIS; CANCER; TOMOGRAPHY; CARCINOMA;
D O I
10.1016/S0221-0363(09)73590-5
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose. TO determine the performance of a CAD system for lung nodules with ground glass Opacity Component Oil multidetector-row CT. Materials and methods. The CT examinations of 17 patients with at least one persistent subsolid nodule were reviewed. A First non-blinded consensus review by two expert radiologists resulted in the detection of 104 subsolid nodules larger than 3 mm (74 nodules of ground glass attenuation and 30 mixed nodules With solid and ground glass components). The results from this review were used as a gold standard to determine the performances of the CAD system and 3 independent clinical radiologists involved with the primary interpretations. Results. The sensitivity of the CAD system for the detection of ground glass opacities and mixed nodules Was 53% and 73% respectively. These values were not statistically different from the values for the 3 independent observers (42-66% for ground glass opacities and 63-80% for mixed nodules). The sensitivity of each observer significantly increased when the nodules detected by the CA D system were added to those detected by each observer (p<0.0001). Conclusion. A CAD system has a potential impact on the detection rate Of subsolid nodules by radiologists.
引用
收藏
页码:1843 / 1849
页数:7
相关论文
共 30 条
[1]   Pulmonary nodules at chest CT: Effect of computer-aided diagnosis on radiologists' detection performance [J].
Awai, K ;
Murao, K ;
Ozawa, A ;
Komi, M ;
Hayakawa, H ;
Hori, S ;
Nishimura, Y .
RADIOLOGY, 2004, 230 (02) :347-352
[2]  
BARSKY SH, 1994, MODERN PATHOL, V7, P633
[3]   Management of an incidentally discovered pulmonary nodule [J].
Beigelman-Aubry, Catherine ;
Hill, Catherine ;
Grenier, Philippe A. .
EUROPEAN RADIOLOGY, 2007, 17 (02) :449-466
[4]   Computer-aided detect ion of lung nodules on thin collimation MDCT: impact on radiologists' performance [J].
Brochu, B. ;
Beigelman-Aubry, C. ;
Goldmard, J-L ;
Raffy, P. ;
Grenier, P. A. ;
Lucidarme, O. .
JOURNAL DE RADIOLOGIE, 2007, 88 (04) :573-578
[5]   Lung micronodules: Automated method for detection at thin-section CT - Initial experience [J].
Brown, MS ;
Goldin, JG ;
Suh, RD ;
McNitt-Gray, MF ;
Sayre, JW ;
Aberle, DR .
RADIOLOGY, 2003, 226 (01) :256-262
[6]   Small pulmonary nodules:: Effect of two computer-aided detection systems on radiologist performance [J].
Das, Marco ;
Muehlenbruch, Georg ;
Mahnken, Andreas H. ;
Flohr, Thomas G. ;
Guendel, Lutz ;
Stanzel, Sven ;
Kraus, Thomas ;
Guenther, Rolf W. ;
Wildberger, Joachim E. .
RADIOLOGY, 2006, 241 (02) :564-571
[7]   Fleischner Society:: Glossary of terms tor thoracic imaging [J].
Hansell, David M. ;
Bankier, Alexander A. ;
MacMahon, Heber ;
McLoud, Theresa C. ;
Mueller, Nestor L. ;
Remy, Jacques .
RADIOLOGY, 2008, 246 (03) :697-722
[8]   CT screening for lung cancer: Frequency and significance of part-solid and nonsolid nodules [J].
Henschke, CI ;
Yankelevitz, DF ;
Mirtcheva, R ;
McGuinness, G ;
McCauley, D ;
Miettinen, OS .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2002, 178 (05) :1053-1057
[9]   Progression of focal pure ground-glass opacity detected by low-dose helical computed tomography screening for lung cancer [J].
Kakinuma, R ;
Ohmatsu, H ;
Kaneko, M ;
Kusumoto, M ;
Yoshida, J ;
Nagai, K ;
Nishiwaki, Y ;
Kobayashi, T ;
Tsuchiya, R ;
Nishyama, H ;
Matsui, E ;
Eguchi, K ;
Moriyama, N .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2004, 28 (01) :17-23
[10]   Persistent pulmonary nodular ground-glass opacity at thin-section CT: Histopathologic comparisons [J].
Kim, Ha Young ;
Shim, Young Mog ;
Lee, Kyung Soo ;
Han, Joungho ;
Yi, Chin A. ;
Kim, Yoon Kyung .
RADIOLOGY, 2007, 245 (01) :267-275