Homogeneous preparation encoding (HoPE) in multislice imaging

被引:3
作者
Fautz, HP [1 ]
Scheffler, K [1 ]
Hennig, J [1 ]
机构
[1] Univ Hosp Freiburg, Dept Radiol, Sect Med Phys, D-79106 Freiburg, Germany
关键词
magnetization preparation; multislice imaging; chemical shift imaging; phase encoding trajectory;
D O I
10.1002/mrm.10281
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Fast magnetization preparation techniques acquire a series of echoes after a single magnetization preparation. If these echoes are acquired from different slices using a multislice technique the change in the preparation state of the echoes due to relaxation effects leads to different contrast modification for each slice. Encoding different preparation states along the phase-encoding direction of each slice instead of acquiring each slice in a different preparation state is introduced as a general concept to obtain images of identical contrast and point-spread function. This can be realized either by cycling the slice excitation order several times over the total number of repetitions or by moving the point of time at which the preparation is applied within each repetition. One possible application of this method is chemical shift selective fat saturation imaging. A homogeneous fat suppression across a multislice volume could be achieved using a FLASH sequence at a repetition time of TR = 145 ms, including a single fat saturation preparation. Conventional fat saturated spin-echo imaging at any TR can be accelerated significantly by reducing the number of applied preparations per repetition. A further application of the homogeneous preparation encoding (HoPE) method is described that encodes the spatial self-saturation of the multislice excitation order homogeneously in all slices. Only a reduced number of slices of the total volume are excited in each repetition and the slice excitation order is continuously moved along the imaging volume. This method is applied foe time of flight (TOF) imaging. Using a TONE-like series of flip angles for the slice excitations of each repetition homogeneous TOF images can be obtained on the basis of a multislice acquisition. (C) 2002 Wiley-Liss, Inc.
引用
收藏
页码:745 / 752
页数:8
相关论文
共 15 条
[1]   IMPROVED MR-ANGIOGRAPHY - MAGNETIZATION-TRANSFER SUPPRESSION WITH VARIABLE FLIP ANGLE EXCITATION AND INCREASED RESOLUTION [J].
ATKINSON, D ;
BRANTZAWADZKI, M ;
GILLAN, G ;
PURDY, D ;
LAUB, G .
RADIOLOGY, 1994, 190 (03) :890-894
[2]   Whole-body MR imaging in 30 seconds with real-time true FISP and a continuously rolling table platform: Feasibility study [J].
Barkhausen, J ;
Quick, HH ;
Lauenstein, T ;
Goyen, M ;
Ruehm, SG ;
Laub, G ;
Debatin, JF ;
Ladd, ME .
RADIOLOGY, 2001, 220 (01) :252-256
[3]  
BRITTAIN JH, 2000, P 8 ANN M ISMRM DENV, P1726
[4]  
DIETRICH O, 1999, P 7 ANN M ISMRM PHIL, P1653
[5]  
FAUTZ HP, 2001, P 9 ANN M ISMRM GLAS, P233
[6]  
FINN JP, 1996, P 4 ANN SCI M ISMRM, P1475
[7]   SNAPSHOT FLASH MRI - APPLICATIONS TO T1, T2, AND CHEMICAL-SHIFT IMAGING [J].
HAASE, A .
MAGNETIC RESONANCE IN MEDICINE, 1990, 13 (01) :77-89
[8]   OVERLAPPING SECTION COVERAGE IN MULTISECTION IMAGING [J].
HENNIG, J .
JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1993, 3 (02) :425-432
[9]   FLAIR imaging using nonselective inversion pulses combined with slice excitation order cycling and k-space reordering to reduce flow artifacts [J].
Herlihy, AH ;
Oatridge, A ;
Curati, WL ;
Puri, BK ;
Bydder, GM ;
Hajnal, JV .
MAGNETIC RESONANCE IN MEDICINE, 2001, 46 (02) :354-364
[10]   MULTISECTION FAT-WATER IMAGING WITH CHEMICAL-SHIFT SELECTIVE PRESATURATION [J].
KELLER, PJ ;
HUNTER, WW ;
SCHMALBROCK, P .
RADIOLOGY, 1987, 164 (02) :539-541