Common-Mode Voltage Reduction in Capacitive Sensing of Biosignal Using Capacitive Grounding and DRL Electrode

被引:5
作者
Bednar, Tadeas [1 ]
Babusiak, Branko [1 ]
Labuda, Michal [1 ]
Smetana, Milan [1 ]
Borik, Stefan [1 ]
机构
[1] Univ Zilina, Dept Electromagnet & Biomed Engn, Zilina 01026, Slovakia
关键词
capacitive sensing; common-mode noise; noise suppression; grounding; DRL; ECG; SYSTEM;
D O I
10.3390/s21072568
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A capacitive measurement of the biosignals is a very comfortable and unobtrusive way suitable for long-term and wearable monitoring of health conditions. This type of sensing is very susceptible to noise from the surroundings. One of the main noise sources is power-line noise, which acts as a common-mode voltage at the input terminals of the acquisition unit. The origin and methods of noise reduction are described on electric models. Two methods of noise removal are modeled and experimentally verified in the paper. The first method uses a passive capacitive grounding electrode, and the second uses an active capacitive Driven Right Leg (DRL) electrode. The effect of grounding electrode size on noise suppression is experimentally investigated. The increasing electrode area reduces power-line noise: the power of power-line frequency within the measured signal is 70.96 dB, 59.13 dB, and 43.44 dB for a grounding electrode area of 1650 cm(2), 3300 cm(2), and 4950 cm(2), respectively. The capacitive DRL electrode shows better efficiency in common-mode noise rejection than the grounding electrode. When using an electrode area of 1650 cm(2), the DRL achieved 46.3 dB better attenuation than the grounding electrode at power-line frequency. In contrast to the grounding electrode, the DRL electrode reduces a capacitive measurement system's financial costs due to the smaller electrode area made of the costly conductive textile.
引用
收藏
页数:17
相关论文
共 30 条
[1]  
Asl S.N., 2015, Curr. Dir. Biomed. Eng., V1, P34
[2]  
Babusiak B., 2020, J VLAKNA TEXTIL, V3, P25
[3]   Smart Sheet Design for Electrocardiogram Measurement [J].
Babusiak, Branko ;
Borik, Stefan ;
Smondrk, Maros ;
Janousek, Ladislav .
INFORMATION TECHNOLOGY IN BIOMEDICINE, 2019, 1011 :507-517
[4]   Textile electrodes in capacitive signal sensing applications [J].
Babusiak, Branko ;
Borik, Stefan ;
Balogova, Ludmila .
MEASUREMENT, 2018, 114 :69-77
[5]   The impact of active electrode guard layer in capacitive measurements of biosignals [J].
Bednar, Tadeas ;
Babusiak, Branko ;
Smondrk, Maros ;
Cap, Ivo ;
Borik, Stefan .
MEASUREMENT, 2021, 171
[6]   Measurement of capacitive coupled ECG from the car seat [J].
Bednar, Tadeas ;
Babusiak, Branko .
13TH INTERNATIONAL SCIENTIFIC CONFERENCE ON SUSTAINABLE, MODERN AND SAFE TRANSPORT (TRANSCOM 2019), 2019, 40 :1260-1265
[7]   Common-Mode Noise Reduction in Noncontact Biopotential Acquisition Circuit Based on Imbalance Cancellation of Electrode-Body Impedance [J].
Chen, Minghui ;
Wang, Jianqing ;
Anzai, Daisuke ;
Fischer, Georg ;
Kirchner, Jens .
SENSORS, 2020, 20 (24) :1-17
[8]   Dry and Noncontact EEG Sensors for Mobile Brain-Computer Interfaces [J].
Chi, Yu Mike ;
Wang, Yu-Te ;
Wang, Yijun ;
Maier, Christoph ;
Jung, Tzyy-Ping ;
Cauwenberghs, Gert .
IEEE TRANSACTIONS ON NEURAL SYSTEMS AND REHABILITATION ENGINEERING, 2012, 20 (02) :228-235
[9]   A comprehensive model for power line interference in biopotential measurements [J].
Chimeno, MF ;
Pallàs-Areny, R .
IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2000, 49 (03) :535-540
[10]  
Hofmann U., 2011, P 5 INT ICST C PERV, DOI [10.4108/icst.pervasivehealth.2011.246051, DOI 10.4108/ICST.PERVASIVEHEALTH.2011.246051]