Common-Mode Voltage Reduction in Capacitive Sensing of Biosignal Using Capacitive Grounding and DRL Electrode

被引:5
|
作者
Bednar, Tadeas [1 ]
Babusiak, Branko [1 ]
Labuda, Michal [1 ]
Smetana, Milan [1 ]
Borik, Stefan [1 ]
机构
[1] Univ Zilina, Dept Electromagnet & Biomed Engn, Zilina 01026, Slovakia
关键词
capacitive sensing; common-mode noise; noise suppression; grounding; DRL; ECG; SYSTEM;
D O I
10.3390/s21072568
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A capacitive measurement of the biosignals is a very comfortable and unobtrusive way suitable for long-term and wearable monitoring of health conditions. This type of sensing is very susceptible to noise from the surroundings. One of the main noise sources is power-line noise, which acts as a common-mode voltage at the input terminals of the acquisition unit. The origin and methods of noise reduction are described on electric models. Two methods of noise removal are modeled and experimentally verified in the paper. The first method uses a passive capacitive grounding electrode, and the second uses an active capacitive Driven Right Leg (DRL) electrode. The effect of grounding electrode size on noise suppression is experimentally investigated. The increasing electrode area reduces power-line noise: the power of power-line frequency within the measured signal is 70.96 dB, 59.13 dB, and 43.44 dB for a grounding electrode area of 1650 cm(2), 3300 cm(2), and 4950 cm(2), respectively. The capacitive DRL electrode shows better efficiency in common-mode noise rejection than the grounding electrode. When using an electrode area of 1650 cm(2), the DRL achieved 46.3 dB better attenuation than the grounding electrode at power-line frequency. In contrast to the grounding electrode, the DRL electrode reduces a capacitive measurement system's financial costs due to the smaller electrode area made of the costly conductive textile.
引用
收藏
页数:17
相关论文
共 50 条
  • [1] Capacitive voltage probe for non-contact measurement of common-mode voltage
    Kobayashi, R
    Tajima, K
    Hiroshima, Y
    Kuwabara, N
    Hattori, M
    ELECTROMAGNETIC COMPATIBILITY 1999, 1999, : 545 - 550
  • [2] Common-mode noise reduction circuit design for biosignal acquisition system-in comparison with the DRL
    Chen M.
    Wang J.
    Anzai D.
    Fischer G.
    IEEJ Transactions on Fundamentals and Materials, 2019, 139 (12) : 657 - 662
  • [3] A novel non-contact capacitive probe for common-mode voltage measurement
    Kobayashi, Ryuichi
    Hiroshima, Yoshiharu
    Ito, Hidenori
    Furuya, Hiroyuki
    Hattori, Mitsuo
    Tada, Yasuhiko
    IEICE TRANSACTIONS ON COMMUNICATIONS, 2007, E90B (06) : 1329 - 1337
  • [4] Active common-mode filter for capacitive-coupled isolated signalling
    Angerer, M.
    Schwanninger, R.
    Maerz, M.
    ELECTRONICS LETTERS, 2020, 56 (02) : 73 - 75
  • [5] Common-mode oscillation in capacitive-coupled differential Colpitts oscillators
    Yodprasit, U.
    Enz, C. C.
    Gimmel, P.
    ELECTRONICS LETTERS, 2007, 43 (21) : 1127 - 1129
  • [6] Common-Mode Voltage Reduction for Paralleled Inverters
    Jiang, Dong
    Shen, Zewei
    Wang, Fei
    IEEE TRANSACTIONS ON POWER ELECTRONICS, 2018, 33 (05) : 3961 - 3974
  • [8] Common-Mode Voltage Reduction for Regenerative AC Drives
    Tallam, Rangarajan M.
    Valdez, Carlos D. Rodrguez
    Kerkman, Russel J.
    Skibinski, Gary L.
    Lukaszewski, Richard A.
    2012 IEEE ENERGY CONVERSION CONGRESS AND EXPOSITION (ECCE), 2012, : 3301 - 3308
  • [9] CISPR 22 conducted common mode voltage measurements along a wire using a capacitive voltage probe
    Harlacher, BL
    Stewart, RW
    2002 IEEE INTERNATIONAL SYMPOSIUM ON ELECTROMAGNETIC COMPATIBILITY, VOLS 1 AND 2, SYMPOSIUM RECORD, 2002, : 1 - 5
  • [10] Common-mode EMI Reduction Method and Filter Configuration for Equipment without Grounding
    Mastuhisa, Shogo
    Ikuta, Eiji
    Shimizu, Toshihisa
    IECON 2017 - 43RD ANNUAL CONFERENCE OF THE IEEE INDUSTRIAL ELECTRONICS SOCIETY, 2017, : 7006 - 7011