Fabrication of Low-Cost Patient-Specific Vascular Models for Particle Image Velocimetry

被引:26
作者
Ruedinger, Katrina L. [1 ,3 ]
Medero, Rafael [2 ,3 ]
Roldan-Alzate, Alejandro [1 ,2 ,3 ]
机构
[1] Univ Wisconsin, Dept Biomed Engn, Madison, WI USA
[2] Univ Wisconsin, Dept Mech Engn, Madison, WI 53706 USA
[3] Univ Wisconsin, WIMR, Dept Radiol, 2476,1111 Highland Ave, Madison, WI 53705 USA
基金
美国国家卫生研究院;
关键词
Particle image velocimetry; Patient-specific; Compliant vascular model; 3D printing; AORTIC-ARCH; FLOW; PHANTOM;
D O I
10.1007/s13239-019-00417-2
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Purpose Particle image velocimetry (PIV), an in vitro experimentation technique that optically measures velocity components to analyze fluid velocity fields, has become increasingly popular to study flow dynamics in various vascular territories. However, it can be difficult and expensive to create patient-specific clear models for PIV due to the importance of refractive index matching of the model and the fluid. We aim to implement and test the use of poly-vinyl alcohol (PVA) in a lost-core casting technique to create low-cost, patient-specific models for PIV. Methods Anonymized patient vascular anatomies were segmented and processed in Mimics/3Matic to create patient-specific cores from 3D digital subtraction angiographies. The cores were 3D-printed with PVA and post-processed with a 80:20 water:glue mixture to smooth the surface. Two silicones, Sylgard 184 and Solaris, were used to encapsulate the model and the PVA core was dissolved using warm water. Computed tomography scans were used to evaluate geometric accuracy using circumferences and surface differences in the model. Results Mean geometric differences in circumference along the inlet centerline and the mean surface difference in the aneurysm between the final Silicone Model and the desired STL Print geometry were statistically insignificant (0.6 mm, 95% CI [- 1.4, 2.8] and 0.3 mm 95% CI [- 0.1, 0.7], respectively). Particle illumination within each model was successful. The cost of one 10 cm x 10 cm x 5 cm model was $69. Conclusion This technique was successful to implement and test the use of PVA in a lost-core casting technique to create low-cost, patient-specific in vitro models for PIV experimentation.
引用
收藏
页码:500 / 507
页数:8
相关论文
共 35 条
[1]  
[Anonymous], 184 SYLGARDTM DOW CO
[2]  
Arcaute K., 2008, J MANUFACTURING SCI, V130, P1
[3]   On the refractive index of sodium iodide solutions for index matching in PIV [J].
Bai, Kunlun ;
Katz, Joseph .
EXPERIMENTS IN FLUIDS, 2014, 55 (04)
[4]   A realistic coronary artery phantom for particle image velocimetry - Featuring injection-molded inclusions and multiple layers [J].
Brunette, J ;
Mongrain, R ;
Tardif, JC .
JOURNAL OF VISUALIZATION, 2004, 7 (03) :241-248
[5]  
Buchoux A, 2015, IEEE ENG MED BIO, P5908, DOI 10.1109/EMBC.2015.7319736
[6]   In vitro flow investigations in the aortic arch during cardiopulmonary bypass with stereo-PIV [J].
Buesen, Martin ;
Kaufmann, Tim A. S. ;
Neidlin, Michael ;
Steinseifer, Ulrich ;
Sonntag, Simon J. .
JOURNAL OF BIOMECHANICS, 2015, 48 (10) :2005-2011
[7]   MRI Segmentation of the Human Brain: Challenges, Methods, and Applications [J].
Despotovic, Ivana ;
Goossens, Bart ;
Philips, Wilfried .
COMPUTATIONAL AND MATHEMATICAL METHODS IN MEDICINE, 2015, 2015
[8]   PIV-measured versus CFD-predicted flow dynamics in anatomically realistic cerebral aneurysm models [J].
Ford, Matthew D. ;
Nikolov, Hristo N. ;
Milner, Jaques S. ;
Lownie, Stephen P. ;
DeMont, Edwin M. ;
Kalata, Wojciech ;
Loth, Francis ;
Holdsworth, David W. ;
Steinman, David A. .
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 2008, 130 (02)
[9]  
Geoghegan P., 2013, EXPT FLUIDS, V54, P1, DOI DOI 10.1007/S00348-013-1528-0
[10]   Fabrication of rigid and flexible refractive-index-matched flow phantoms for flow visualisation and optical flow measurements [J].
Geoghegan, P. H. ;
Buchmann, N. A. ;
Spence, C. J. T. ;
Moore, S. ;
Jermy, M. .
EXPERIMENTS IN FLUIDS, 2012, 52 (05) :1331-1347