Rationally defined safety factors for filter sizing

被引:13
作者
Lutz, Herbert [1 ]
机构
[1] Millipore Corp, Playa Del Rey, CA 90293 USA
关键词
Safety factor; Process variability; Scale-up; Filter sizing; SCALE-UP; ULTRAFILTRATION; MICROFILTRATION; FILTRATION;
D O I
10.1016/j.memsci.2009.06.015
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
Safety factors are empirical multipliers of a base case design filter area based on judgment. This analysis provides a rationale for assigning safety factor values based on designing a robust process that allows for scale differences, process variability, data extrapolation, and process expansion. It is applied to a variety of biopharmaceutical filter applications including final sterile filtration, dual sterile filtration, clarification, buffer sterilization. virus filtration, and ultrafiltration. Some filtration costs increase with area but there is an expected cost of failing to process the batch within a validated window of conditions that decreases with area. A variability factor is defined as the minimum cost area divided by a base case area. The base case area has a 50% chance of failing to process the batch when expected values of the process parameters are used. Variability factors can fall in the range of 1.1-2.5 for different filter applications. Process models combined with variability data are used to determine the sources and magnitude of process variability. The bioprocessing cases considered here imply that process variability generally arises primarily from feedstock and filter variability with operating conditions contributing as well for ultrafiltration. However, these relative proportions are very application specific. (C) 2009 Elsevier B.V. All rights reserved.
引用
收藏
页码:268 / 278
页数:11
相关论文
共 31 条
[1]  
[Anonymous], 1964, HDB MATH FUNCTIONS
[2]  
Badmington F., 1995, PHARM TECH, V19, P64
[3]   Combined models of membrane fouling: Development and application to microfiltration and ultrafiltration of biological fluids [J].
Bolton, G ;
LaCasse, D ;
Kuriyel, R .
JOURNAL OF MEMBRANE SCIENCE, 2006, 277 (1-2) :75-84
[4]  
FISHER FA, 1926, METRON, V5, P90
[5]  
*GEN, 2007 ANN REP 17 COST
[6]  
Giglia Sal, 2007, PDA J Pharm Sci Technol, V61, P314
[7]  
GOODRICH E, 2009, COMMUNICATION NOV
[8]  
HILDEBRAND FB, 1962, ADVANCED CALCULUS AP, P360
[9]   A combined pore blockage and cake filtration model for protein fouling during microfiltration [J].
Ho, CC ;
Zydney, AL .
JOURNAL OF COLLOID AND INTERFACE SCIENCE, 2000, 232 (02) :389-399
[10]   PROCESS CAPABILITY INDEXES [J].
KANE, VE .