Active energy selective image detector for dual-energy computed radiography

被引:17
作者
Alvarez, RE
机构
[1] Aprend Technology, Mountain View
关键词
x-ray; dual-energy; computed radiography; storage phosphor;
D O I
10.1118/1.597831
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
A new energy selective detector for dual energy computed radiography has been developed that combines many of the advantages of x-ray tube voltage switching and single exposure double screen detectors. The new active detector utilizes electro-optical modulation of the response of the storage phosphor screens to allow dual exposure acquisition with no motion of the screens. Electrooptical modulation can be done rapidly so the detector can acquire the voltage switched images in a short enough time to minimize patient motion artifacts. Voltage switching produces effective detected energy spectra that result in much lower noise for a given patient dose than the effective spectra of double screen detectors. In this paper the new concept is' described, optimal voltages and filter materials are determined by computer simulations, and the active detector performance is compared to other energy selective detectors. The new detector provides over 30 times better signal to noise ratio squared (SNR(2)) for the same dose and over five times better SNR(2) for the same x-ray tube loading than a double screen detector. The effects of incomplete erasure of the x-ray exposures are determined quantitatively. With achievable erasing fractions, the SNR(2) is over 20 times better for the same dose and over three times better for constant tube loading than a double screen detector. The active detector is also compared to mechanical screen switching. Mechanical switching provides somewhat better SNR(2) for the same dose, approximately 1.1 times the active detector SNR(2) at optimal x-ray tube voltages. The performance is compared with highly absorbing back screens. If these are used in both the active and passive detectors, both detectors' quality factors increase, but the advantage of the active detector over the passive detector decreases with large back screen thicknesses. (C) 1996 American Association of Physicists in Medicine.
引用
收藏
页码:1739 / 1748
页数:10
相关论文
共 28 条
[1]   COMPARISON OF NOISE AND DOSE IN CONVENTIONAL AND ENERGY SELECTIVE COMPUTED-TOMOGRAPHY [J].
ALVAREZ, R ;
SEPPI, E .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1979, 26 (02) :2853-2855
[2]  
Alvarez R E, 1977, U.S. Patent, Patent No. [4 029 963 1977 (USA), 4029963]
[3]   ENERGY-SELECTIVE RECONSTRUCTIONS IN X-RAY COMPUTERIZED TOMOGRAPHY [J].
ALVAREZ, RE ;
MACOVSKI, A .
PHYSICS IN MEDICINE AND BIOLOGY, 1976, 21 (05) :733-744
[4]  
ALVAREZ RE, 1993, Patent No. 5221843
[5]  
Alvarez RE., 1976, THESIS STANFORD U
[6]   PARAMETRIZED X-RAY ABSORPTION IN DIAGNOSTIC-RADIOLOGY FROM MONTE-CARLO CALCULATIONS - IMPLICATIONS FOR X-RAY-DETECTOR DESIGN [J].
BOONE, JM .
MEDICAL PHYSICS, 1992, 19 (06) :1467-1473
[7]   DUAL-ENERGY MAMMOGRAPHY - A DETECTOR ANALYSIS [J].
BOONE, JM ;
SHABER, GS ;
TECOTZKY, M .
MEDICAL PHYSICS, 1990, 17 (04) :665-675
[8]   AN ENERGY SENSITIVE CASSETTE FOR DUAL-ENERGY MAMMOGRAPHY [J].
CHAKRABORTY, DP ;
BARNES, GT .
MEDICAL PHYSICS, 1989, 16 (01) :7-13
[9]   KINETICS OF PHOTOSTIMULATED LUMINESCENCE IN BAFBR-EU [J].
DELEEUW, DM ;
KOVATS, T ;
HERKO, SP .
JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 1987, 134 (02) :491-493
[10]  
DYSON NA, 1973, XRAYS ATOMIC NUCLEAR