Seasonality of PCDD/Fs in the ambient air of Malopolska Region, southern Poland

被引:24
作者
Umlauf, Gunther [1 ]
Christoph, Eugen H. [1 ]
Eisenreich, Steven J. [2 ]
Mariani, Giulio [1 ]
Paradiz, Bostjan [1 ,3 ]
Vives, Ingrid [1 ]
机构
[1] European Commiss Joint Res Ctr JRC, IES, I-21027 Ispra, Italy
[2] European Commiss JRC, Directorate Programs & Stakeholder Relat, B-1049 Brussels, Belgium
[3] Minist Environm & Spatial Planning, Ljubljana 1000, Slovenia
关键词
2,3,7,8-PCDD; 2,3,7,8-PCDF; Aleje; Benzo(a)pyrene; Dioxin; Domestic heating; Furan; Krakow; Nowa Huta; PCDD; PCDF; PM10; Persistent organic chemicals; Poland; POPs; Steel industry; Wood/coal combustion; Zakopane; DIBENZO-P-DIOXINS; PCBS; PCDFS; ATMOSPHERE; EMISSIONS; INVENTORY; FURANS;
D O I
10.1007/s11356-009-0215-4
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The aim of the study was to identify the impact of polychlorinated dibenzo-p-dioxin and furan (PCDD/F) emission sources on ambient air concentrations in the Malopolska Region, southern Poland. Three sites were selected: the city center of Krakow (Aleje), an industrial area (Nova Huta), and a rural site (Zakopane). In order to investigate the annual variations of PCDD/F sources, summer and winter time samples were taken. Ambient air particulate matter (PM10) was collected using an Anderson High-Volume sampler during June and December 2002 in the three mentioned sites. Analysis of PCDD/Fs was based on isotope dilution using high-resolution gas chromatography-high-resolution mass spectrometry for quantification. Total concentrations of 2,3,7,8-PCDD/Fs in air particulate phase from Malopolska region ranged from 0.6 to 37 pg m(-3) (0.04-3.2 pg WHO98-TEQ per cubic meter, 0.037-2.9 pg I-TEQ per cubic meter). Higher PCDD/F concentrations were measured at all three sites during winter. A linear correlation among PCDD/F concentrations, benzo(a)pyrene (B(a)P) and PM10 concentrations, was found in Aleje and Zakopane, which suggested that all compounds were originating from the same source, solid fuel domestic heating. Instead, PCDD/F levels in Nova Huta did not correlate with the seasonality of B(a)P or PM10 levels and 2,3,7,8-PCDD/F congener patterns for this site were significantly different from the other sites. Domestic solid fuel combustion is likely the main PCDD/F source in winter in this part of Poland for urban and rural sites. PCDD/F fingerprints in the industrial site remained almost identical during summer and winter, confirming the yearly prevalence of the emissions from the nearby metal industry. PCDD/F concentrations found in Malopolska Region are in the upper range of ambient air concentrations of PCDD/Fs reported worldwide. However, further research is needed in order to study the impact of the deposition of these PCDD/F emissions on the region. A more extended study is being conducted in the area to analyze soil samples, such as sink of atmospheric deposition, and spruce needles, as indicator of PCDD/F availability.
引用
收藏
页码:462 / 469
页数:8
相关论文
共 21 条
[1]   Evaluation of a new automated cleanup system for the analysis of polychlorinated dibenzo-p-dioxins and dibenzofurans in environmental samples [J].
Abad, E ;
Sauló, J ;
Caixach, J ;
Rivera, J .
JOURNAL OF CHROMATOGRAPHY A, 2000, 893 (02) :383-391
[2]   Global mass balance for polychlorinated dibenzo-p-dioxins and dibenzofurans [J].
Brzuzy, LP ;
Hites, RA .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 1996, 30 (06) :1797-1804
[3]   Cross-cultural consistency of the demand/withdraw interaction pattern in couples [J].
Christensen, Andrew ;
Eldridge, Kathleen ;
Catta-Preta, Adriana Bokel ;
Lim, Veronica R. ;
Santagata, Rossella .
JOURNAL OF MARRIAGE AND FAMILY, 2006, 68 (04) :1029-1044
[4]  
Christoph E.H., 2005, ORGANOHALOGEN COMPOU, V67, P1205
[5]   A general indication of the contemporary background levels of PCDDs, PCDFs, and coplanar PCBs in the ambient air over rural and remote areas of the united states [J].
Cleverly, David ;
Ferrario, Joseph ;
Byrne, Christian ;
Riggs, Karen ;
Joseph, Darrell ;
Hartford, Pamela .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2007, 41 (05) :1537-1544
[6]   Concentrations and vapor-particle partitioning of polychlorinated dibenzo-p-dioxins and dibenzofurans in ambient air of Houston, TX [J].
Correa, O ;
Rifai, H ;
Raun, L ;
Suarez, M ;
Koenig, L .
ATMOSPHERIC ENVIRONMENT, 2004, 38 (39) :6687-6699
[7]   Dioxins and furans in the atmosphere of Sao Paulo City, Brazil [J].
de Assunçao, JV ;
Pesquero, UR ;
Bruns, RE ;
Carvalho, LRF .
CHEMOSPHERE, 2005, 58 (10) :1391-1398
[8]  
*EUR STAT BOOKS, 2007, EN YEARL STAT 2005
[9]   Pcdds and pcdfs concentration in combustion gases and bottom ash from incineration of hospital, wastes in Poland [J].
Grochowalski, A .
CHEMOSPHERE, 1998, 37 (9-12) :2279-2291
[10]  
Grochowalski A., 1997, ORGANOHALOGEN COMPOU, V32, P76