Symptoms after mould exposure including Stachybotrys chartarum, and comparison with darkroom disease

被引:24
作者
Al-Ahmad, M. [2 ]
Manno, M. [3 ,4 ]
Ng, V. [5 ]
Ribeiro, M. [1 ,2 ,6 ]
Liss, G. M. [3 ,4 ]
Tarlo, S. M. [1 ,2 ,3 ,4 ]
机构
[1] Toronto Western Hosp, Div Resp, Toronto, ON M5T 2S8, Canada
[2] Univ Toronto, Dept Med, Toronto, ON, Canada
[3] Dalla Lana Sch Publ Hlth, Toronto, ON, Canada
[4] Gage Occupat & Environm Hlth Unit, Toronto, ON, Canada
[5] Univ Western Ontario, Sch Med, London, ON, Canada
[6] Univ Sao Paulo, Div Pulm, Heart Inst Incor, Sch Med, Sao Paulo, Brazil
关键词
darkroom disease; mould; multiple chemical sensitivity; sick building syndrome; Stachybotrys chartarum; SICK BUILDING SYNDROME; RESPIRATORY SYMPTOMS; TOXIGENIC FUNGI; HOME DAMPNESS; INDOOR MOLD; HEALTH; ASTHMA; ASSOCIATIONS; MYCOTOXINS; RADIOGRAPHERS;
D O I
10.1111/j.1398-9995.2009.02157.x
中图分类号
R392 [医学免疫学];
学科分类号
100102 ;
摘要
P>Background: Mould-attributed symptoms have included features which overlap with unexplained syndromes such as sick building syndrome. Objectives: We describe questionnaire and chart review findings in patients following exposure to moulds which include Stachybotrys and compare responses with two control groups. Methods: Thirty-two patients presented with symptoms attributed to mould exposures. Exposure identification for 25 patients had reported S tachybotrys chartarum as well as other mould (Aspergillus, Penicillium), 88% at work. The remaining seven had professionally visualized or self-reported/photographic exposure evidence only. A chart review was performed and a follow-up with a questionnaire, including questions on current health status, and nonspecific symptoms. Results: Cough, shortness of breath and chest tightness (at presentation) were reported in 79%, 70% and 64%, respectively, and persisted > 6 weeks in 91%. Skin test(s) were positive to fungal extract(s) in 30%. Seventeen returned questionnaires were obtained 3.1 (SD 0.5) years after the initial clinic assessment. Among this subgroup, persisting asthma-like symptoms and symptoms suggestive of sick building syndrome were frequent, and similar to a group previously assessed for darkroom disease among medical radiation technologists. The mould-exposed group more commonly reported they were bothered when walking in a room with carpets, complained of a chemical or metallic taste in their mouth, and had problems in concentration when compared with a control physiotherapist group (P < 0.005). Conclusions: Although only a minority with health concerns from indoor mould exposure had demonstrable mould-allergy, a significant proportion had asthma-like symptoms. Other symptoms were also common and persistent after the initial implicated exposure.
引用
收藏
页码:245 / 255
页数:11
相关论文
共 38 条
  • [1] Sick building syndrome - a wolf in sheep's clothing
    Bardana, EJ
    [J]. ANNALS OF ALLERGY ASTHMA & IMMUNOLOGY, 1997, 79 (04) : 283 - 293
  • [2] Effects on patients with asthma of eradicating visible indoor mould: a randomised controlled trial
    Burr, M. L.
    Matthews, I. P.
    Arthur, R. A.
    Watson, H. L.
    Gregory, C. J.
    Dunstan, F. D. J.
    Palmer, S. R.
    [J]. THORAX, 2007, 62 (09) : 767 - 772
  • [3] The medical effects of mold exposure
    Bush, RK
    Portnoy, JM
    Saxon, A
    Terr, AI
    Wood, RA
    [J]. JOURNAL OF ALLERGY AND CLINICAL IMMUNOLOGY, 2006, 117 (02) : 326 - 333
  • [4] Centers for Disease Control and Prevention (CDC), 2000, MMWR Morb Mortal Wkly Rep, V49, P180
  • [5] Psychological, neuropsychological, and electrocortical effects of mixed mold exposure
    Crago, BR
    Nelson, LA
    Davis, M
    Arnold, L
    Thrasher, JD
    [J]. ARCHIVES OF ENVIRONMENTAL HEALTH, 2003, 58 (08): : 452 - 463
  • [6] DEARBORN DG, 1994, MMWR-MORBID MORTAL W, V43, P881
  • [7] MYCOTOXINS AND REPRODUCTION IN DOMESTIC LIVESTOCK
    DIEKMAN, MA
    GREEN, ML
    [J]. JOURNAL OF ANIMAL SCIENCE, 1992, 70 (05) : 1615 - 1627
  • [8] (1→3)-β-D-glucans and respiratory health:: a review of the scientific evidence
    Douwes, J
    [J]. INDOOR AIR, 2005, 15 (03) : 160 - 169
  • [9] Meta-analyses of the associations of respiratory health effects with dampness and mold in homes
    Fisk, W. J.
    Lei-Gomez, Q.
    Mendell, M. J.
    [J]. INDOOR AIR, 2007, 17 (04) : 284 - 296
  • [10] Gareis M, 2000, MYCOSES, V43, P79