CFD analysis of high frequency miniature pulse tube refrigerators for space applications with thermal non-equilibrium model

被引:51
作者
Ashwin, T. R. [1 ]
Narasimham, G. S. V. L. [1 ]
Jacob, Subhash [2 ]
机构
[1] Indian Inst Sci, Dept Mech Engn, Bangalore 560012, Karnataka, India
[2] Indian Inst Sci, Ctr Cryogen Technol, Bangalore 560012, Karnataka, India
关键词
Cryocoolers; Pulse tube; Regenerator; Oscillatory flow; Inertance tube; INERTANCE TUBE; FLOW;
D O I
10.1016/j.applthermaleng.2009.07.015
中图分类号
O414.1 [热力学];
学科分类号
摘要
High frequency, miniature, pulse tube cryocoolers are extensively used in space applications because of their simplicity. Parametric studies of inertance type pulse tube cooler are performed with different length-to-diameter ratios of the pulse tube with the help of the FLUENT (R) package. The local thermal non-equilibrium of the gas and the matrix is taken into account for the modeling of porous zones, in addition to the wall thickness of the components. Dynamic characteristics and the actual mechanism of energy transfer in pulse are examined with the help of the pulse tube wall time constant. The heat interaction between pulse tube wall and the oscillating gas, leading to surface heat pumping, is quantified. The axial heat conduction is found to reduce the performance of the pulse tube refrigerator. The thermal non-equilibrium predicts a higher cold heat exchanger temperature compared to thermal equilibrium. The pressure drop through the porous medium has a strong non-linear effect due to the dominating influence of Forchheimer term over that of the linear Darcy term at high operating frequencies. The phase angle relationships among the pressure, temperature and the mass flow rate in the porous zones are also important in determining the performance of pulse tube refrigerator. (C) 2009 Elsevier Ltd. All rights reserved.
引用
收藏
页码:152 / 166
页数:15
相关论文
共 19 条
[1]  
[Anonymous], 2003, THESIS GEORGIA I TEC
[2]  
ASHWIN TR, 2009, CRYOCOOLERS, V15, P271
[3]  
ASHWIN TR, 2008, P CHT 08 ICHMT INT S, V1
[4]   Multi-dimensional flow effects in pulse tube refrigerators [J].
Cha, J. S. ;
Ghiaasiaan, S. M. ;
Desai, P. V. ;
Harvey, J. P. ;
Kirkconnell, C. S. .
CRYOGENICS, 2006, 46 (09) :658-665
[5]   The effective thermal conductivity of wire screen [J].
Chen Li ;
Peterson, G. P. .
INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2006, 49 (21-22) :4095-4105
[6]   THERMODYNAMIC ANALYSIS OF THE BASIC PULSE-TUBE REFRIGERATOR [J].
DEBOER, PCT .
CRYOGENICS, 1994, 34 (09) :699-711
[7]  
Flake B, 2004, AIP CONF PROC, V710, P1493, DOI 10.1063/1.1774843
[8]  
FLAKES B, 2003, P INT CRYOG ENG C SE, P1493
[9]  
*FLUENT INC, FLUENT 6 3 US GUID
[10]  
Gifford WE, 1964, ADV CRYOGEN ENG, V12, P619