Unsynchronised two-terminal transmission-line fault-location without using line parameters

被引:47
|
作者
Liao, Y.
Elangovan, S.
机构
[1] Univ Kentucky, Dept Elect & Comp Engn, Lexington, KY 40506 USA
[2] Natl Univ Singapore, Dept Elect Engn, Fac Engn, Singapore 119260, Singapore
关键词
D O I
10.1049/ip-gtd:20060026
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The paper presents a new two-terminal transmission-line fault-location algorithm without requiring line parameters. The voltage and current measurements at both ends of a transmission line during a fault are assumed to be available and no synchronisation of the data is required. The proposed algorithm is suitable for estimating the location of asymmetric faults on a line when line parameters are not available. Evaluation studies using both simulated and field data are reported.
引用
收藏
页码:639 / 643
页数:5
相关论文
共 50 条
  • [1] Transmission line fault location algorithm using trust-region method and two-terminal unsynchronised data
    Li, Xun
    Shi, Shuai-Jun
    Gong, Qing-Wu
    Gaodianya Jishu/High Voltage Engineering, 2010, 36 (02): : 396 - 400
  • [2] Transmission line fault location using two-terminal data without time synchronization
    Silveira, Eduardo G.
    Pereira, Clever
    IEEE TRANSACTIONS ON POWER SYSTEMS, 2007, 22 (01) : 498 - 499
  • [3] Accurate Two-Terminal Transmission Line Fault Location Using Traveling Waves
    Lopes, Felipe V.
    Dantas, Karcius M.
    Silva, Kleber M.
    Costa, Flavio B.
    IEEE TRANSACTIONS ON POWER DELIVERY, 2018, 33 (02) : 873 - 880
  • [4] Accurate transmission line fault location using two-terminal measurement data without time synchronisation
    Rosolowski, Eugeniusz
    Izykowski, Jan
    Saha, Murari M.
    Balcerek, Przemyslaw
    Fulczyk, Marek
    PRZEGLAD ELEKTROTECHNICZNY, 2009, 85 (06): : 170 - 174
  • [5] A Closed-Form Solution for Transmission-Line Fault Location Without the Need of Terminal Synchronization or Line Parameters
    Vieira, Douglas A. G.
    Oliveira, Diogo B.
    Lisboa, Adriano C.
    IEEE TRANSACTIONS ON POWER DELIVERY, 2013, 28 (02) : 1238 - 1239
  • [6] New fault location scheme for a two-terminal transmission line using synchronized phasor measurements
    Brahma, S. M.
    2005/2006 IEEE/PES TRANSMISSION & DISTRIBUTION CONFERENCE & EXPOSITION, VOLS 1-3, 2006, : 853 - 857
  • [7] Unsynchronised fault-location technique for three-terminal lines
    Mahamedi, Behnam
    Sanaye-Pasand, Majid
    Azizi, Sadegh
    Zhu, Jian Guo
    IET GENERATION TRANSMISSION & DISTRIBUTION, 2015, 9 (15) : 2099 - 2107
  • [8] Review of the intelligent fault-location in the transmission line
    Xie, Yehui
    Liu, Chi
    Wang, Mei
    INTERNATIONAL SYMPOSIUM ON ARTIFICIAL INTELLIGENCE AND ROBOTICS 2021, 2021, 11884
  • [9] Asynchronous two-terminal fault location method of transmission line based on parameter modification
    Wang F.
    Mu K.
    Zhang J.
    Liu Y.
    Qian Y.
    Dianli Zidonghua Shebei/Electric Power Automation Equipment, 2018, 38 (08): : 95 - 101
  • [10] Two-terminal Asynchronous Fault Location Method for MMC-HVDC Transmission Line
    Yang Y.
    Huang C.
    Jiang Y.
    Liu P.
    Tang T.
    Huang, Chun (yellowpure@hotmail.com), 2018, Automation of Electric Power Systems Press (42): : 148 - 154