Determination of surface dose in pencil beam scanning proton therapy

被引:9
作者
Kern, A. [1 ,2 ,3 ,4 ]
Baeumer, C. [1 ,2 ,3 ,4 ,5 ]
Kroeninger, K. [3 ]
Mertens, L. [6 ]
Timmermann, B. [1 ,2 ,4 ,5 ,7 ]
Walbersloh, J. [8 ]
Wulff, J. [1 ,2 ,4 ]
机构
[1] West German Proton Therapy Ctr Essen WPE, D-45147 Essen, Germany
[2] Univ Hosp Essen, D-45147 Essen, Germany
[3] TU Dortmund Univ, Expt Phys 4, D-44227 Dortmund, Germany
[4] West German Canc Ctr WTZ, D-45147 Essen, Germany
[5] German Canc Consortium DKTK, D-69120 Heidelberg, Germany
[6] Heidelberg Univ, Univ Med Ctr Mannheim, D-68167 Mannheim, Germany
[7] Clin Particle Therapy, D-45147 Essen, Germany
[8] Mat Prufungsamt Nordrhein Wes, D-44287 Dortmund, Germany
关键词
build‐ up effect; extrapolation chamber; Monte Carlo simulation; proton therapy; skin depth; skin dose; surface dose; TOPAS; RADIOCHROMIC FILM; BREAST-CANCER; EBT3; FILMS; SKIN; DOSIMETRY; PHOTON; THICKNESS; BUILDUP; IRRADIATION; MANAGEMENT;
D O I
10.1002/mp.14086
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose/objective Quantification of surface dose within the first few hundred water equivalent mu m is challenging. Nevertheless, it is of large interest for the proton therapy community to study dose effects in the skin. The experimental determination is affected by the detector properties, such as the detector volume and material. The International Commission on Radiation Units and Measurements in its report 39 recommends assessing the skin dose at a depth of 0.07 mm. The aim of this study is the estimation of the absorbed dose at and around a depth of 70 mu m. We used various dosimetric approaches in conjunction with proton pencil beam scanning delivery to determine the skin dose in a clinical setting. Material/methods Five different detectors were tested for determining the surface dose in water: EBT3 and HD-V2 GAFCHROMIC (TM) radiochromic film, LiF:Mg,Ti thermoluminescent dosimeter, IBA PPC05 plane-parallel ionization chamber, and PTW 23391 extrapolation chamber. The irradiation setup consisted of quasi-monoenergetic scanned proton pencil beams with kinetic energies of 100, 150, and 226.7 MeV, respectively. Radiochromic films were placed within a vertical stack and in wedge geometry and were analyzed with FilmQA Pro (TM) adopting triple channel dosimetry. The extrapolation chamber PTW 23391, which served as a reference in the current work, was used in a conventional ionization chamber setup with a fixed electrode gap of 2 mm. Three Kapton (R) entrance windows with thicknesses of 25, 50, and 75 mu m were employed. Thermoluminescent dosimeters were provided as powder and were pressed onto a sheet of aluminum. Furthermore, the Monte Carlo code TOol for PArticle Simulation (TOPAS) in version 3.1.p2 was used to model an IBA pencil beam scanning nozzle and score dose to water in a water phantom. Results The resulting depth dose curves were normalized to their 100% dose at the reference depth of 3 cm. We obtained the skin doses with the extrapolation chamber and with TOPAS. For the experimental approach this resulted in 79.7 +/- 0.3%, 86.0 +/- 0.6%, and 87.1 +/- 0.1% for the proton energies 100, 150, and 226.7 MeV, respectively. The results for TOPAS were 80.1 +/- 0.2% (100 MeV), 87.1 +/- 0.5% (150 MeV), and 86.9 +/- 0.4% (226.7 MeV), respectively. Based on the experimental results of the skin dose, we provided a clinically relevant surface extrapolation factor for the common measurement methods. This allows the result of the first measurement depth of a detector to be scaled to the dose at the skin depth. Most practical would be the use of the surface extrapolation factor for the PPC05 chamber, due to its direct reading, the wide availability in clinics and the low uncertainties. The calculated factors were 0.986 +/- 0.004 for 100 MeV, 0.961 +/- 0.008 for 150 MeV, and 0.963 +/- 0.003 for 226.7 MeV. Conclusions In this study, dissimilar experimental approaches were evaluated with respect to measurements at depths close to the surface. The experimental depth dose curves are in good agreement with the simulation with TOPAS Monte Carlo. To the author's knowledge this was the first experimental determination of the skin dose according to the International Commission on Radiation Units and Measurements 39 definition in proton pencil beam scanning.
引用
收藏
页码:2277 / 2288
页数:12
相关论文
共 48 条
[1]   Surface and Buildup Region Dose Measurements with Markus Parallel-Plate Ionization Chamber, GafChromic EBT3 Film, and MOSFET Detector for High-Energy Photon Beams [J].
Akbas, Ugur ;
Kesen, Nazmiye Donmez ;
Koksal, Canan ;
Bilge, Hatice .
ADVANCES IN HIGH ENERGY PHYSICS, 2016, 2016
[2]  
[Anonymous], 1992, 59 ICRP
[3]  
[Anonymous], 2004, 69802 ISO, P1
[4]   Measurement of absolute activation cross sections from carbon and aluminum for proton therapy [J].
Baeumer, Christian ;
Baecker, Claus Maximilian ;
Gerhardt, Marcel ;
Grusell, Erik ;
Koska, Benjamin ;
Kroeninger, Kevin ;
Nitsch, Christian ;
Rullkoetter, Hannah ;
Siregar, Hilda Milani ;
Timmermann, Beate ;
Verbeek, Nico ;
Wulff, Joerg ;
Yazgan, Azad .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2019, 440 :75-81
[5]   Dosimetry intercomparison of four proton therapy institutions in Germany employing spot scanning [J].
Baeumer, Christian ;
Ackermann, Benjamin ;
Hillbrand, Martin ;
Kaiser, Franz -Joachim ;
Koska, Benjamin ;
Latzel, Harald ;
Luehr, Armin ;
Menkel, Stefan ;
Timmermann, Beate .
ZEITSCHRIFT FUR MEDIZINISCHE PHYSIK, 2017, 27 (02) :80-85
[6]   A dosimetry system for fast measurement of 3D depth-dose profiles in charged-particle tumor therapy with scanning techniques [J].
Brusasco, C ;
Voss, B ;
Schardt, D ;
Krämer, M ;
Kraft, G .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2000, 168 (04) :578-592
[7]   Megavoltage x-ray skin dose variation with an angle using grid carbon fibre couch tops [J].
Butson, Martin J. ;
Cheung, Tsang ;
Yu, Peter K. N. .
PHYSICS IN MEDICINE AND BIOLOGY, 2007, 52 (20) :N485-N492
[8]   Extrapolated surface dose measurements with radiochromic film [J].
Butson, MJ ;
Yu, PKN ;
Metcalfe, PE .
MEDICAL PHYSICS, 1999, 26 (03) :485-488
[9]  
CARLSSON CA, 1977, HEALTH PHYS, V33, P481