Comparison of visual acuities at different distances and defocus curves

被引:36
作者
Pieh, S
Kellner, C
Hanselmayer, G
Lackner, B
Schmidinger, G
Walkow, T
Sticker, M
Weghaupt, H
Fetcher, AF
Skorpik, C
机构
[1] Univ Vienna, Sch Med, Dept Ophthalmol & Optometry, A-1090 Vienna, Austria
[2] Univ Vienna, Inst Med Phys, A-1090 Vienna, Austria
[3] AO Krankenhaus St Polten, Dept Ophthalmol, St Polten, Austria
关键词
D O I
10.1016/S0886-3350(02)01317-2
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To evaluate how visual acuities at different distances correlate with results from defocus curves. Setting: Department of Ophthalmology and Institute of Medical Physics, University of Vienna, Medical School, Vienna, and Department of Ophthalmology, Krankenhaus St. Polten, St. Polten, Austria. Methods: This study comprised 15 eyes of 14 patients with a mean age of 67.9 years +/- 9.7 (SD) with a monofocal silicone intraocular lens (911 A, Pharmacia). The best corrected distance visual acuity was determined at viewing distances of 6 m, 2 m, 1 m, 67 cm, 50 cm, 40 cm, and 33 cm using logMAR charts. Defocus curves were then evaluated from -3.0 to -0.5 diopter (D) at 0.5 D increments from the best distance correction at a viewing distance of 6 m. Results: The mean distance visual acuity was logMAR 0.08 +/- 0.07. The visual acuity graph from the testing at different distances was above the defocus graph at all testing points. Comparison of the visual acuity results from the 2 tests revealed statistically significant differences in the range from 2 m (-0.5 D) to 33 cm (-3.0 D). Conclusion: Results of defocus curves disregard the diminutions of minus glasses, the normally restricted viewing distance to 6 m for distance acuity determination, and in particular the physiological miosis caused by the near-point reaction. (C) 2002 ASCRS and ESCRS.
引用
收藏
页码:1964 / 1967
页数:4
相关论文
共 16 条
[1]  
[Anonymous], 1992, ADLERS PHYSL EYE
[2]   DEPTH OF FOCUS AND FUNCTIONAL RESULTS IN PATIENTS WITH MULTIFOCAL INTRAOCULAR LENSES - A LONG-TERM FOLLOW-UP [J].
AUFFARTH, GU ;
HUNOLD, W ;
WESENDAHL, TA ;
MEHDORN, E .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1993, 19 (06) :685-689
[3]  
BLECKMANN H, 1987, INTRAOKULARE LINSEN
[4]   OPTICAL-PERFORMANCE OF BIFOCAL AND MULTIFOCAL INTRAOCULAR LENSES TESTED WITH A NEW DEVICE [J].
EISENMANN, D ;
JACOBI, KW ;
REINER, J .
KLINISCHE MONATSBLATTER FUR AUGENHEILKUNDE, 1992, 201 (06) :381-387
[5]   PSEUDOACCOMMODATION OF DIFFRACTIVE MULTIFOCAL LENSES AND MONOFOCAL LENSES [J].
HUNOLD, W ;
AUFFARTH, G ;
WESENDAHL, T ;
MEHDORN, E ;
KUCK, G .
KLINISCHE MONATSBLATTER FUR AUGENHEILKUNDE, 1993, 202 (01) :19-23
[6]  
Jacobi FK, 1999, ARCH OPHTHALMOL-CHIC, V117, P17
[7]  
JAKOBI KW, 1993, KLIN MONATSBL AUGENH, V202, P309
[8]   Functional findings after bilateral implantation of a foldable refractive multifocal posterior chamber lens [J].
Liekfeld, A ;
Pham, DT ;
Wollensak, J .
KLINISCHE MONATSBLATTER FUR AUGENHEILKUNDE, 1995, 207 (05) :283-286
[9]  
POST CT, 1992, OPHTHALMOLOGY, V99, P1658
[10]  
Post Jr CT, 1992, OPHTHALMOLOGY, V99, P1663