Feasibility of Low Volume of High-Concentration Iodinated Contrast Medium With 70 kVp Tube Voltage on High-Pitch Dual-Source Computed Tomography Angiography in Children With Congenital Heart Disease

被引:1
作者
Nie, Pei [1 ]
Guo, Jian [1 ]
Yang, Zhitao [1 ]
Li, Xiaoli [1 ]
Yang, Guangjie [2 ]
机构
[1] Qingdao Univ, Dept Radiol, Affiliated Hosp, Qingdao, Shandong, Peoples R China
[2] Qingdao Univ, Dept Nucl Med, Affiliated Hosp, 59 Haier Rd, Qingdao 266000, Shandong, Peoples R China
关键词
congenital heart disease; dual-source CT; contrast medium; high pitch; radiation exposure;
D O I
10.1097/RCT.0000000000001033
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objective The objective of this study was to investigate the feasibility of high-concentration iodinated contrast medium (CM) with 70 kVp tube voltage on high-pitch dual-source computed tomography (DSCT) in children with congenital heart disease (CHD). Methods Fifty-eight CHD patients underwent high-pitch DSCT in 2 protocols: 70 kVp tube voltage, 1.0 mL/kg CM volume, 370 mg I/mL concentration (group A); 80 kVp tube voltage, 1.5 mL/kg CM volume, 350 mg I/mL concentration (group B). The diagnostic accuracy, image quality, iodine delivery rate, iodine dose, and radiation dose were compared. Results There was no significant difference in the diagnostic accuracy (P > 0.05), image quality (P > 0.05) and iodine delivery rate (P > 0.05) between the 2 groups. The iodine dose (P < 0.05) and radiation dose (P < 0.05) in group A were significantly lower than those in group B. Conclusions Reduction in iodine dose and radiation exposure can be achieved with 70 kVp high-pitch DSCT by administering a smaller volume of high-concentration CM in children with CHD.
引用
收藏
页码:52 / 58
页数:7
相关论文
共 26 条
[1]   Low radiation dose in computed tomography: the role of iodine [J].
Aschoff, Andrik J. ;
Catalano, Carlo ;
Kirchin, Miles A. ;
Krix, Martin ;
Albrecht, Thomas .
BRITISH JOURNAL OF RADIOLOGY, 2017, 90 (1076)
[2]   Evaluation of image quality and radiation dose of thoracic and coronary dual-source CT in 110 infants with congenital heart disease [J].
Ben Saad, Moez ;
Rohnean, Adela ;
Sigal-Cinqualbre, Anne ;
Adler, Ghazal ;
Paul, Jean-Francois .
PEDIATRIC RADIOLOGY, 2009, 39 (07) :668-676
[3]   Comparison of image quality between 70 kVp and 80 kVp: application to paediatric cardiac CT [J].
Durand, Sebastien ;
Paul, Jean-Francois .
EUROPEAN RADIOLOGY, 2014, 24 (12) :3003-3009
[4]   Iodine Concentration and Optimization in Computed Tomography Angiography Current Issues [J].
Faggioni, Lorenzo ;
Gabelloni, Michela .
INVESTIGATIVE RADIOLOGY, 2016, 51 (12) :816-822
[5]   Two-Phase Contrast Injection Protocol for Pediatric Cardiac Computed Tomography in Children with Congenital Heart Disease [J].
Fukuyama, Naoki ;
Kurata, Akira ;
Kawaguchi, Naoto ;
Tashiro, Ryo ;
Higaki, Takashi ;
Yokoi, Takahiro ;
Tanabe, Yuki ;
Nishiyama, Hikaru ;
Itoh, Toshihide ;
Kido, Teruhito ;
Miyagawa, Masao ;
Mochizuki, Teruhito .
PEDIATRIC CARDIOLOGY, 2018, 39 (03) :518-525
[6]   Cardiac MDCT in Children: CT Technology Overview and Interpretation [J].
Goo, Hyun Woo .
RADIOLOGIC CLINICS OF NORTH AMERICA, 2011, 49 (05) :997-+
[7]   State-of-the-Art CT Imaging Techniques for Congenital Heart Disease [J].
Goo, Hyun Woo .
KOREAN JOURNAL OF RADIOLOGY, 2010, 11 (01) :4-18
[8]   Computed Tomography Imaging in Patients with Congenital Heart Disease Part I: Rationale and Utility. An Expert Consensus Document of the Society of Cardiovascular Computed Tomography (SCCT) [J].
Han, B. Kelly ;
Rigsby, Cynthia K. ;
Hlavacek, Anthony ;
Leipsic, Jonathon ;
Nicol, Edward D. ;
Siegel, Marilyn J. ;
Bardo, Dianna ;
Abbara, Suhny ;
Ghoshhajra, Brian ;
Lesser, John R. ;
Raman, Subha ;
Crean, Andrew M. .
JOURNAL OF CARDIOVASCULAR COMPUTED TOMOGRAPHY, 2015, 9 (06) :475-492
[9]   Computed Tomography Imaging in Patients with Congenital Heart Disease, Part 2: Technical Recommendations. An Expert Consensus Document of the Society of Cardiovascular Computed Tomography (SCCT) [J].
Han, B. Kelly ;
Rigsby, Cynthia K. ;
Leipsic, Jonathon ;
Bardo, Dianna ;
Abbara, Suhny ;
Ghoshhajra, Brian ;
Lesser, John R. ;
Raman, Subha V. ;
Crean, Andrew M. ;
Nicol, Edward D. ;
Siegel, Marilyn J. ;
Hlavacek, Anthony .
JOURNAL OF CARDIOVASCULAR COMPUTED TOMOGRAPHY, 2015, 9 (06) :493-513
[10]   Computed tomography contrast enhancement principles and the use of high-concentration contrast media [J].
Herman, S .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2004, 28 :S7-S11