Beam angle evaluation to improve inter-fraction motion robustness in pelvic lymph node irradiation with proton therapy

被引:12
作者
Andersen, Andreas Gravgaard [1 ]
Casares-Magaz, Oscar [1 ]
Petersen, Jorgen [1 ]
Toftegaard, Jakob [1 ]
Bentzen, Lise [2 ]
Thornqvist, Sara [3 ,4 ]
Muren, Ludvig Paul [1 ]
机构
[1] Aarhus Univ, Dept Med Phys, Aarhus Univ Hosp, Aarhus, Denmark
[2] Aarhus Univ, Aarhus Univ Hosp, Inst Phys & Astron, Dept Oncol, Aarhus, Denmark
[3] Haukeland Hosp, Sect Med Phys, Bergen, Norway
[4] Univ Bergen, Dept Phys & Technol, Bergen, Norway
关键词
RANGE UNCERTAINTIES; PROSTATE-CANCER; LUNG-CANCER; PLAN ROBUSTNESS; RADIOTHERAPY; OPTIMIZATION; VOLUME; SETUP; SELECTION;
D O I
10.1080/0284186X.2017.1317108
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Background: Proton therapy dose distributions are sensitive to range variations, e.g. arising from inter-fraction organ motion. The aim of this study was to evaluate the inter-fraction motion robustness of proton beams from different beam angles in irradiation of pelvic lymph nodes (LNs).Material and methods: Planning CT (pCT) and multiple repeat CT (rCT) scans of 18 prostate cancer patients were used. Considering left and right LNs separately, the average water equivalent path length (WEPL) over all ray paths in the beams eye view of the LNs were calculated for all gantry/couch angle combinations across all rCTs versus the corresponding pCT. Single beam proton plans were optimized on the pCT for all gantry angles (0 degrees couch) and were re-calculated on all rCTs for each respective patient. WEPL and dose parameters were extracted and a statistical clustering analysis performed to identify patient sub-populations in terms of patterns in which angles were robust.Results: The WEPL analysis showed a general pattern of least variation for 0 degrees couch beam angles where three minima were found across gantry angles for the left LNs and two for the right LNs. The clustering analysis identified three patient sub-groups for the left LNs and two groups for the right LNs. The dose calculations showed similar results as the WEPL variation, e.g. for the left LNs angles around 25 degrees-35 degrees, 100 degrees-110 degrees, and 160 degrees-170 degrees were consistently preferable for both target and organs at risk.Conclusions: Sub-populations of patients with similar patterns of WEPL variations across beam angles were identified. The most robust angles found for WEPL variations were also confirmed by the dose/volume analysis.
引用
收藏
页码:846 / 852
页数:7
相关论文
共 37 条
[1]   A method for evaluation of proton plan robustness towards inter- fractional motion applied to pelvic lymph node irradiation [J].
Andersen, Andreas G. ;
Casares-Magaz, Oscar ;
Muren, Ludvig P. ;
Toftegaard, Jakob ;
Bentzen, Lise ;
Thornqvist, Sara ;
Petersen, Jorgen B. B. .
ACTA ONCOLOGICA, 2015, 54 (09) :1643-1650
[2]   4D Optimized Treatment Planning for Actively Scanned Proton Therapy Delivered to Moving Target Volume [J].
Bernatowicz, K. ;
Zhang, Y. ;
Weber, D. ;
Lomax, A. .
MEDICAL PHYSICS, 2015, 42 (06) :3615-3615
[3]   Comparative study of layered and volumetric rescanning for different scanning speeds of proton beam in liver patients [J].
Bernatowicz, K. ;
Lomax, A. J. ;
Knopf, A. .
PHYSICS IN MEDICINE AND BIOLOGY, 2013, 58 (22) :7905-7920
[4]   Improved Beam Angle Arrangement in Intensity Modulated Proton Therapy Treatment Planning for Localized Prostate Cancer [J].
Cao, Wenhua ;
Lim, Gino J. ;
Li, Yupeng ;
Zhu, X. Ronald ;
Zhang, Xiaodong .
CANCERS, 2015, 7 (02) :574-584
[5]   A method for selection of beam angles robust to intra-fractional motion in proton therapy of lung cancer [J].
Casares-Magaz, Oscar ;
Toftegaard, Jakob ;
Muren, Ludvig P. ;
Kallehauge, Jesper F. ;
Bassler, Niels ;
Poulsen, Per R. ;
Petersen, Jorgen B. B. .
ACTA ONCOLOGICA, 2014, 53 (08) :1058-1063
[6]   The choice of statistical methods for comparisons of dosimetric data in radiotherapy [J].
Chaikh, Abdulhamid ;
Giraud, Jean-Yves ;
Perrin, Emmanuel ;
Bresciani, Jean-Pierre ;
Balosso, Jacques .
RADIATION ONCOLOGY, 2014, 9
[7]   Clinical Implementation of Intensity Modulated Proton Therapy for Thoracic Malignancies [J].
Chang, Joe Y. ;
Li, Heng ;
Zhu, X. Ronald ;
Liao, Zhongxing ;
Zhao, Lina ;
Liu, Amy ;
Li, Yupeng ;
Sahoo, Narayan ;
Poenisch, Falk ;
Gomez, Daniel R. ;
Wu, Richard ;
Gillin, Michael ;
Zhang, Xiaodong .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2014, 90 (04) :809-818
[8]   Including robustness in multi-criteria optimization for intensity-modulated proton therapy [J].
Chen, Wei ;
Unkelbach, Jan ;
Trofimov, Alexei ;
Madden, Thomas ;
Kooy, Hanne ;
Bortfeld, Thomas ;
Craft, David .
PHYSICS IN MEDICINE AND BIOLOGY, 2012, 57 (03) :591-608
[9]   Investigation of bladder dose and volume factors influencing late urinary toxicity after external beam radiotherapy for prostate cancer [J].
Cheung, M. Rex ;
Tucker, Susan L. ;
Dong, Lei ;
de Crevoisier, Renaud ;
Lee, Andrew K. ;
Frank, Steven ;
Kudchadker, Rajat J. ;
Thames, Howard ;
Mohan, Radhe ;
Kuban, Deborah .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2007, 67 (04) :1059-1065
[10]   Physics Controversies in Proton Therapy [J].
Engelsman, Martijn ;
Schwarz, Marco ;
Dong, Lei .
SEMINARS IN RADIATION ONCOLOGY, 2013, 23 (02) :88-96