The adaptive gain integrating pixel detector

被引:8
作者
Allahgholi, A. [1 ]
Becker, J. [1 ]
Bianco, L. [1 ]
Bradford, R. [6 ]
Delfs, A. [1 ]
Dinapoli, R. [2 ]
Goettlicher, P. [1 ]
Gronewald, M. [4 ]
Graafsma, H. [1 ,5 ]
Greiffenberg, D. [2 ]
Henrich, B. H. [2 ]
Hirsemann, H. [1 ]
Jack, S. [1 ]
Klanner, R. [3 ]
Klyuev, A. [1 ]
Krueger, H. [4 ]
Lange, S. [1 ]
Marras, A. [1 ]
Mezza, D. [2 ]
Mozzanica, A. [2 ]
Perova, I. [1 ]
Xia, Q. [1 ]
Schmitt, B. [2 ]
Schwandt, J. [3 ]
Sheviakov, I. [1 ]
Shi, X. [2 ]
Trunk, U. [1 ]
Zhang, J. [1 ]
机构
[1] DESY, D-22607 Hamburg, Germany
[2] Paul Scherrer Inst, OFLB-006, CH-5232 Villigen, Switzerland
[3] Univ Hamburg, D-22761 Hamburg, Germany
[4] Univ Bonn, D-53115 Bonn, Germany
[5] Mid Sweden Univ, Sundsvall, Sweden
[6] Adv Photon Source, Chicago, IL USA
关键词
X-ray detectors; X-ray detectors and telescopes; X-ray diffraction detectors; ELECTRONICS;
D O I
10.1088/1748-0221/11/02/C02066
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The adaptive gain integrating pixel detector (AGIPD) is a development of a collaboration between Deustsches Elektronen-Synchrotron (DESY), the Paul-Scherrer-Institute (PSI), the University of Hamburg and the University of Bonn. The detector is designed to cope with the demanding challenges of the European XFEL. Therefore it comes along with an adaptive gain stage allowing a high dynamic range, spanning from single photon sensitivity to 10(4) x 12.4 keV photons and 352 analogue memory cells per pixel. The aim of this report is to briefly explain the concepts of the AGIPD electronics and mechanics and then present recent experiments demonstrating the functionality of its key features.
引用
收藏
页数:9
相关论文
共 9 条
[1]  
Altarelli M., 2007, TECHNICAL REPORT
[2]   Performance tests of an AGIPD 0.4 assembly at the beamline P10 of PETRA III [J].
Becker, J. ;
Marras, A. ;
Klyuev, A. ;
Westermeier, F. ;
Trunk, U. ;
Graafsma, H. .
JOURNAL OF INSTRUMENTATION, 2013, 8
[3]  
Becker J, 2011, IEEE NUCL SCI CONF R, P1950, DOI 10.1109/NSSMIC.2011.6154392
[4]   NOISE FILTERING FOR READOUT ELECTRONICS [J].
BUTTLER, W ;
HOSTICKA, BJ ;
LUTZ, G .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1990, 288 (01) :187-190
[5]   Requirements for and development of 2 dimensional X-ray detectors for the European X-ray Free Electron Laser in Hamburg [J].
Graafsma, Heinz .
JOURNAL OF INSTRUMENTATION, 2009, 4
[6]   Optimization of the noise performance of the AGIPD prototype chips [J].
Greiffenberg, D. ;
Becker, J. ;
Bianco, L. ;
Dinapoli, R. ;
Goettlicher, P. ;
Graafsma, H. ;
Hirsemann, H. ;
Jack, S. ;
Klanner, R. ;
Klyuev, A. ;
Krueger, H. ;
Lange, S. ;
Marras, A. ;
Mozzanica, A. ;
Rah, S. ;
Schmitt, B. ;
Schwandt, J. ;
Sheviakov, I. ;
Shi, X. ;
Trunk, U. ;
Zhang, J. ;
Zimmer, M. .
JOURNAL OF INSTRUMENTATION, 2013, 8
[7]  
Macrander A., 2015, P SRI IN PRESS
[8]   Front end electronics for European XFEL sensor: The AGIPD project [J].
Marras, A. ;
Trunk, U. ;
Klyuev, A. ;
Becker, J. ;
Graafsma, H. ;
Shi, X. ;
Greiffenberg, D. ;
Schmitt, B. .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2013, 731 :79-82
[9]   Design of the AGIPD sensor for the European XFEL [J].
Schwandt, J. ;
Fretwurst, E. ;
Klanner, R. ;
Zhang, J. .
JOURNAL OF INSTRUMENTATION, 2013, 8