MEMS Accelerometer Calibration Denoising Method for Hopkinson Bar System Based on LMD-SE-TFPF

被引:13
|
作者
Yan, Zeyu [1 ]
Hou, Boyang [2 ]
Zhang, Jingchun [3 ]
Shen, Chong [1 ]
Shi, Yunbo [1 ]
Tang, Jun [1 ]
Cao, Huiliang [1 ]
Liu, Jun [1 ]
机构
[1] North Univ China, Sci & Technol Elect Test & Measurement Lab, Taiyuan 030051, Shanxi, Peoples R China
[2] Univ Elect Sci & Technol China, Glasgow Coll, Chengdu 610054, Sichuan, Peoples R China
[3] Beijing Huijia Private Sch, Beijing 102200, Peoples R China
来源
IEEE ACCESS | 2019年 / 7卷
基金
山西省青年科学基金; 中国国家自然科学基金;
关键词
High-G MEMS accelerometer (HGMA); denoising; local mean decomposition (LMD); sample entropy (SE); time-frequency peak filtering (TFPF); Hopkinson bar; FAULT-DIAGNOSIS; DECOMPOSITION; EXTRACTION; DESIGN;
D O I
10.1109/ACCESS.2019.2935129
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
High-G MEMS accelerometer (HGMA) is widely used in the aerospace field and the precise control of missiles. Therefore, its calibration accuracy is critical to sensor performance and the overall control system. In order to decrease the influence of noise on the HGMA output signal, a hybrid denoising algorithm which is based on the Time-frequency peak filtering (TFPF), Local mean decomposition (LMD) and Sample entropy (SE) has been proposed in this article. For the problem that the TFPF algorithm is limited in the choice of window length, LMD and SE are used to distinguish components, which can improve the TFPF algorithm effectively. It provides a better balance between noise reduction and signal fidelity. Firstly, the noise-containing signal can be decomposed by LMD to obtain PFs. Secondly, calculate the sample entropy values of each PFs, then divide the signal into mixed component, useful component and noise component according to the similarity of sample entropy. Thirdly, the mixed component can use long-window TFPF to reduce noise, the short-window TFPF can reduce the noise for the useful component, and the noise component can be wiped off directly. Finally, the useful component and the mixed component are both reconstructed to form the final denoised signal. Experiments have showed that this method can not only remove noise (the noise of static signal is reduced by 91.76%, the signal-noise ratio of dynamic signal has increased to 17.6), but also retain the details of frequency and amplitude (the shock peak amplitude error is 0.062% and the vibration amplitude error is 0.04%). Therefore, this method can reduce the noise of the High-G MEMS accelerometer signal with maintaining the characteristics of the original signal, thereby greatly improves the performance of the accelerometer, making it widely used.
引用
收藏
页码:113901 / 113915
页数:15
相关论文
共 20 条
  • [1] Dynamic characterization method of accelerometers based on the Hopkinson bar calibration system
    Yang, Zhaoxin
    Wang, Qing
    Du, Hongmian
    Fan, Jinbiao
    Liang, Jie
    SENSORS AND ACTUATORS A-PHYSICAL, 2019, 293 : 21 - 28
  • [2] Adjustment of the wave form of high g accelerometer using Hopkinson bar calibration system
    Fan, Jinbiao
    Xu, Peng
    Li, Qingfeng
    PROCEEDINGS OF THE 7TH INTERNATIONAL CONFERENCE ON SHOCK & IMPACT LOADS ON STRUCTURES, 2007, : 217 - +
  • [3] Numerical Simulation of Waveform Adjustment in high G Accelerometer Calibration System Using Hopkinson Bar
    Zhao Xing-liang
    Li Xin-liang
    Xu Peng
    Zhang Da-zhi
    PROCEEDINGS OF THE 2015 3RD INTERNATIONAL CONFERENCE ON MACHINERY, MATERIALS AND INFORMATION TECHNOLOGY APPLICATIONS, 2015, 35 : 182 - 190
  • [4] Rapid calibration method of MEMS accelerometer based on adaptive GA
    Gao S.
    Zhang R.
    Beijing Hangkong Hangtian Daxue Xuebao/Journal of Beijing University of Aeronautics and Astronautics, 2019, 45 (10): : 1982 - 1989
  • [5] Field calibration method of MEMS accelerometer based on ACS algorithm
    Qiao M.
    Gao Y.
    Li W.
    Zhao Y.
    1600, Editorial Department of Journal of Chinese Inertial Technology (29): : 387 - 393
  • [6] High-G MEMS Accelerometer Calibration Denoising Method Based on EMD and Time-Frequency Peak Filtering
    Wang, Chenguang
    Cui, Yuchen
    Liu, Yang
    Li, Ke
    Shen, Chong
    MICROMACHINES, 2023, 14 (05)
  • [7] High-G Calibration Denoising Method for High-G MEMS Accelerometer Based on EMD and Wavelet Threshold
    Lu, Qing
    Pang, Lixin
    Huang, Haoqian
    Shen, Chong
    Cao, Huiliang
    Shi, Yunbo
    Liu, Jun
    MICROMACHINES, 2019, 10 (02)
  • [8] Calibration Analysis of High-G MEMS Accelerometer Sensor Based on Wavelet and Wavelet Packet Denoising
    Shi, Yunbo
    Zhang, Juanjuan
    Jiao, Jingjing
    Zhao, Rui
    Cao, Huiliang
    SENSORS, 2021, 21 (04) : 1 - 17
  • [9] A dynamic calibration method of free-field pressure sensor based on Hopkinson bar
    Liang, Wen
    Chen, Rong
    Zhang, Yuwu
    AIP ADVANCES, 2020, 10 (07)
  • [10] A Digital Calibration Method for a MEMS Accelerometer based on Harmonic Self-Test
    Chen, Dongliang
    Liu, Xiaowei
    Yin, Liang
    QiangFu
    21ST ANNUAL CONFERENCE AND 10TH INTERNATIONAL CONFERENCE OF CHINESE SOCIETY OF MICRO-NANO TECHNOLOGY, 2020, 1520