The Effect of Nucleus Implant Parameters on the Compressive Mechanics of the Lumbar Intervertebral Disc: A Finite Element Study

被引:19
作者
Joshi, Abhijeet [1 ]
Massey, Christopher J. [2 ]
Karduna, Andrew [3 ]
Vresilovic, Edward [4 ]
Marcolongo, Michele [1 ]
机构
[1] Drexel Univ, Dept Mat Sci & Engn, Philadelphia, PA 19104 USA
[2] Drexel Univ, Dept Mech Engn & Mech, Philadelphia, PA 19104 USA
[3] Univ Oregon, Dept Human Physiol, Eugene, OR 97403 USA
[4] Penn State Univ, Dept Orthopaed Surg, Hershey, PA USA
基金
美国国家科学基金会;
关键词
finite element analysis; intervertebral disc; hydrogel; biomechanics; implant design; MESENCHYMAL STEM-CELLS; AGE-RELATED-CHANGES; ARTIFICIAL DISC; STRESS-ANALYSIS; MOTION SEGMENT; NEUTRAL ZONE; IN-VITRO; PULPOSUS; DEGENERATION; REPLACEMENT;
D O I
10.1002/jbm.b.31322
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
A simplified finite element model of the human lumbar intervertebral disc was utilized for understanding nucleus pulposus implant mechanics. The model was used to assess the effect of nucleus implant parameter variations on the resulting compressive biomechanics of the lumbar anterior column unit. The effects of nucleus implant material (modulus and Poisson's ratio) and geometrical (height and diameter) parameters on the mechanical behavior of the disc were investigated. The model predicted that variations in implant modulus contribute less to the compressive disc mechanics compared to the implant geometrical parameters, for the ranges examined. It was concluded that some threshold exists for the nucleus implant modulus, below which little variations in load-displacement behavior were shown. Compressive biomechanics were highly affected by implant volume (under-filling the nucleus cavity, line-to-line fit, or over-filling the nucleus cavity) with a greater restoration of compressive mechanics observed with the over-filled implant design. This work indicated the effect of nucleus implant parameter variations on the compressive mechanics of the human lumbar intervertebral disc and importance of the "fit and fill" effect of the nuclear cavity in the restoration of the human intervertebral disc mechanics in compression. These findings may have clinical significance for nucleus implant design. (C) 2009 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biornater 90B: 596-607, 2009
引用
收藏
页码:596 / 607
页数:12
相关论文
共 48 条
[1]   Poroelastic creep response analysis of a lumbar motion segment in compression [J].
Argoubi, M ;
ShiraziAdl, A .
JOURNAL OF BIOMECHANICS, 1996, 29 (10) :1331-1339
[2]   The artificial disc: Theory, design and materials [J].
Bao, QB ;
McCullen, GM ;
Higham, PA ;
Dumbleton, JH ;
Yuan, HA .
BIOMATERIALS, 1996, 17 (12) :1157-1167
[3]   New technologies in spine -: Nucleus replacement [J].
Bao, QB ;
Yuan, HA .
SPINE, 2002, 27 (11) :1245-1247
[4]   FINITE-ELEMENT STRESS ANALYSIS OF AN INTERVERTEBRAL-DISK [J].
BELYTSCHKO, T ;
KULAK, RF ;
SCHULTZ, AB ;
GALANTE, JO .
JOURNAL OF BIOMECHANICS, 1974, 7 (03) :277-285
[5]   A prospective, randomized, multicenter food and drug administration Investigational device exemptions study of lumbar total disc replacement with the CHARITE™ artificial disc versus lumbar fusion Part I:: Evaluation of clinical outcomes [J].
Blumenthal, S ;
McAfee, PC ;
Guyer, RD ;
Hochschuler, SH ;
Geisler, FH ;
Holt, RT ;
Garcia, R ;
Regan, JJ ;
Ohnmeiss, DD .
SPINE, 2005, 30 (14) :1565-1575
[6]   The role of the nucleus pulposus in neutral zone human lumbar intervertebral disc mechanics [J].
Cannella, Marco ;
Arthur, Amy ;
Allen, Shanee ;
Keane, Michael ;
Joshi, Abhijeet ;
Vresilovic, Edward ;
Marcolongo, Michele .
JOURNAL OF BIOMECHANICS, 2008, 41 (10) :2104-2111
[7]   Silicone synovitis: MR imaging in five patients [J].
Chan, MK ;
Chowchuen, P ;
Workman, T ;
Eilenberg, S ;
Schweitzer, M ;
Resnick, D .
SKELETAL RADIOLOGY, 1998, 27 (01) :13-17
[8]  
Duncan NA, 1998, COMPUTER METHODS IN BIOMECHANICS & BIOMEDICAL ENGINEERING - 2, P527
[9]   Fluid flow and convective transport of solutes within the intervertebral disc [J].
Ferguson, SJ ;
Ito, K ;
Nolte, LP .
JOURNAL OF BIOMECHANICS, 2004, 37 (02) :213-221
[10]   The effect of protein-free versus protein-containing medium on the mechanical properties and uptake of ions of PVA/PVP hydrogels [J].
Fussell, G ;
Thomas, J ;
Scanlon, J ;
Lowman, A ;
Marcolongo, M .
JOURNAL OF BIOMATERIALS SCIENCE-POLYMER EDITION, 2005, 16 (04) :489-503