Assessment of thyroid function in intensive care unit patients by liquid chromatography tandem mass spectrometry methods

被引:15
作者
Welsh, Kerry J.
Stolze, Brian R.
Yu, Xiaolin
Podsiadlo, Trisha R.
Kim, Lisa S.
Soldin, Steven J. [1 ,2 ]
机构
[1] Georgetown Univ, Dept Endocrinol, Washington, DC USA
[2] Georgetown Univ, Dept Metab, Washington, DC USA
基金
美国国家卫生研究院;
关键词
Free thyroid hormone; Total thyroid hormone; LC-MSMS; Immunoassay; FREE-THYROXINE; NONTHYROIDAL ILLNESS; FREE TRIIODOTHYRONINE; UNDILUTED SERUM; EQUILIBRIUM DIALYSIS/RADIOIMMUNOASSAY; HORMONE; IMMUNOASSAY; T-3; HYPOTHYROIDISM; DILUTION;
D O I
10.1016/j.clinbiochem.2016.11.022
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Objectives: Patients with non-thyroidal illness syndrome have many abnormalities in thyroid hormone tests. Such patients have medical comorbidities associated with low serum proteins and are on multiple medications that interfere with thyroid hormone measurement by immunoassay platforms. It is unknown if these thyroid hormone measurements reflect physiologic conditions or if they are artifacts of testing methodology. Methods: Fifty patients were selected from the intensive care unit (ICU) from our institution. Total and free thyroid hormones in plasma were measured by gold standard liquid chromatography-tandem mass spectrometry (LC-MSMS). The results were compared to the Roche Cobas 6000. Patient medical comorbidities and binding protein levels were assessed. Results: Concentrations of total 3,5,5'-triidothyronine (TT3) and total thyroxine (TT4) were significantly more likely to be low by LC-MSMS compared to immunoassay. Free 3,5,5'-triidothyronine (FT3) levels were similar by immunoassay and LC-MSMS. However, FT4 concentrations were mildly elevated for many patients when measured by ultrafiltration LC-MSMS (19/50, 38%) compared to 1/50 (2%) when measured by immunoassay p = 0.0001). Decreased albumin and thyroxine binding globulin were common and patients were on an average of 11.7 +/- 5.0 medications, all factors known to interfere with results found on immunoassays. Conclusions: Marked discrepancies in thyroid hormone measurement were noted between reference LCMSMS and a common immunoassay platform. It is hypothesized that T4 binding to low affinity albumin is displaced by several drugs, raising concentrations of FT4 by LC-MSMS compared to immunoassay, and that the immunoassay values are falsely decreased due to low binding proteins in our patient population. Published by Elsevier Inc. on behalf of The Canadian Society of Clinical Chemists.
引用
收藏
页码:318 / 322
页数:5
相关论文
共 50 条
  • [21] Determination of homocitrulline in urine of patients with HHH syndrome by liquid chromatography tandem mass spectrometry
    Al-Dirbashi, Osama Y.
    Al-Hassnan, Zuhair N.
    Rashed, Mohamed S.
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2006, 386 (7-8) : 2013 - 2017
  • [22] Comparison of gas chromatography-mass spectrometry and liquid chromatography-tandem mass spectrometry methods to quantify α-tocopherol and α-tocopherolquinone levels in human plasma
    Mottier, P
    Gremaud, E
    Guy, PA
    Turesky, RJ
    ANALYTICAL BIOCHEMISTRY, 2002, 301 (01) : 128 - 135
  • [23] A liquid chromatography tandem mass spectrometry method for plasma glucagon
    Nguyen, Van Long
    Tuckwell, Phillip
    Ireland, Andrea
    Fitzpatrick, Michael
    ANALYTICAL BIOCHEMISTRY, 2023, 675
  • [24] Determination of mycotoxins in cereals by liquid chromatography tandem mass spectrometry
    Soleimany, F.
    Jinap, S.
    Abas, F.
    FOOD CHEMISTRY, 2012, 130 (04) : 1055 - 1060
  • [25] Measurement of sex steroids in murine blood and reproductive tissues by liquid chromatography-tandem mass spectrometry
    McNamara, K. M.
    Harwood, D. T.
    Simanainen, U.
    Walters, K. A.
    Jimenez, M.
    Handelsman, D. J.
    JOURNAL OF STEROID BIOCHEMISTRY AND MOLECULAR BIOLOGY, 2010, 121 (3-5) : 611 - 618
  • [26] Determination of Six Thyroid Hormones in the Brain and Thyroid Gland Using Isotope-Dilution Liquid Chromatography/Tandem Mass Spectrometry
    Kunisue, Tatsuya
    Fisher, Jeffrey W.
    Kannan, Kurunthachalam
    ANALYTICAL CHEMISTRY, 2011, 83 (01) : 417 - 424
  • [27] Determination of cyclosporine, tacrolimus, sirolimus and everolimus by liquid chromatography coupled to electrospray ionization and tandem mass spectrometry: Assessment of matrix effects and assay performance
    Vethe, Nils T.
    Gjerdalen, Laila C.
    Bergan, Stein
    SCANDINAVIAN JOURNAL OF CLINICAL & LABORATORY INVESTIGATION, 2010, 70 (08) : 583 - 591
  • [28] Concurrent identification of 11 major primary active compounds in Huangqin Qingfei Decoction by liquid chromatography tandem mass spectrometry via liquid chromatography tandem mass spectrometry
    Zhang, Yi-Fan
    Lu, Ye
    Xiao, Juan
    Chen, Ye
    Wang, Xin-Hong
    PAKISTAN JOURNAL OF PHARMACEUTICAL SCIENCES, 2020, 33 (03) : 1005 - 1013
  • [29] Analysis of Buprenorphine in Whole Blood Using Liquid Chromatography-Tandem Mass Spectrometry
    Stephenson, Jon B.
    JOURNAL OF ANALYTICAL TOXICOLOGY, 2013, 37 (08) : 495 - 499
  • [30] Determination of melatonin in Acyrthosiphon pisum aphids by liquid chromatography-tandem mass spectrometry
    Escriva, Laura
    Manyes, Lara
    Barbera, Miguel
    Martinez-Torres, David
    Meca, Guiseppe
    JOURNAL OF INSECT PHYSIOLOGY, 2016, 86 : 48 - 53