The substitution of the implant and abutment for their analogs in mechanical studies: In vitro and in silico analysis

被引:8
|
作者
Gomes, Rafael Soares [1 ]
Pedroso Bergamo, Edmara Tatiely [1 ]
Bordin, Dimorvan [1 ]
Del Bel Cury, Altair Antoninha [1 ]
机构
[1] Univ Estadual Campinas, Piracicaba Dent Sch, Dept Prosthodont & Periodontol, Av Limeira 901, BR-13414903 Piracicaba, SP, Brazil
来源
MATERIALS SCIENCE AND ENGINEERING C-MATERIALS FOR BIOLOGICAL APPLICATIONS | 2017年 / 75卷
基金
巴西圣保罗研究基金会;
关键词
Dental prosthesis; Dental implants; Mechanical processes; Finite element analysis; CAD/CAM LITHIUM-DISILICATE; FINITE-ELEMENT-ANALYSIS; ALL-CERAMIC CROWNS; FRACTURE-RESISTANCE; STRESS-DISTRIBUTION; FATIGUE; DESIGN; LOAD; RESTORATIONS; STRENGTH;
D O I
10.1016/j.msec.2017.02.034
中图分类号
TB3 [工程材料学]; R318.08 [生物材料学];
学科分类号
0805 ; 080501 ; 080502 ;
摘要
The use of analogs could reduce the cost of mechanical tests involving implant-supported crowns, but it is unclear if it would negatively affect the data accuracy. This study evaluated the substitution of the implant by implants analogs or abutment analogs as a support for crowns in mechanical tests, taking into account stress distribution and fracture load of monolithic lithium disilicate crowns. Thirty lithium disilicate monolithic crowns were randomized into three groups according to the set: Implant + abutment (IA); implant analog + abutment (IAA); abutment analog (AA). The specimens were subjected to mechanical fatigue (10(6) cycles, 200 N, 2 Hz) and thermal fatigue (10(4) cycles, 5 degrees-55 degrees C). A final compression load was applied and the maximum fracture load was recorded. Data were analyzed using one-way ANOVA (alpha = 0.05). The experiment was validated by finite element analysis and the maximum principal stress was recorded. No statistically significant difference was observed in the mean fracture load among groups (P>0.05). The failure mode was similar for all groups with the origin of crack propagation located at the load point application. Finite element analysis showed similar stress distribution and stress peak values for all groups. The use of implant's or abutment's analog does not influence the fracture load and stress distribution for cemented implant-supported crowns. (C) 2017 Elsevier B.V. All rights reserved.
引用
收藏
页码:50 / 54
页数:5
相关论文
共 50 条
  • [31] Implant deformation and implant-abutment fracture resistance after standardized artificial aging: An in vitro study
    Zhai, Zhihao
    Tamaki, Nakano
    Chen, Yuming
    Shota, Watanabe
    Takashi, Matsuoka
    Shoichi, Ishigaki
    CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2023, 25 (01) : 107 - 117
  • [32] Mechanical Comparison of Experimental Conical-Head Abutment Screws with Conventional Flat-Head Abutment Screws for External-Hex and Internal Tri-Channel Implant Connections: An In Vitro Evaluation of Loosening Torque
    Coppede, Abilio Ricciardi
    Lapria Faria, Adriana Claudia
    Chiarello de Mattos, Maria da Gloria
    Silveira Rodrigues, Renata Cristina
    Shibli, Jamil Awad
    Ribeiro, Ricardo Faria
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2013, 28 (06) : E321 - E329
  • [33] Healing Abutment Distortion in Implant Prostheses: An In Vitro Study
    Pandey, Chandrashekhar
    Bhattarai, Bishwa Prakash
    Riddhabhaya, Apiwat
    Wongsirichat, Natthamet
    Rokaya, Dinesh
    JOURNAL OF FUNCTIONAL BIOMATERIALS, 2022, 13 (03)
  • [34] The mechanical complications and behavior of angulated dental implant abutment systems versus conventional abutments, a narrative review
    Albakri, Ahmed
    SAUDI DENTAL JOURNAL, 2024, 36 (08) : 1072 - 1077
  • [35] Effect of angulated abutments on stress concentration at the implant abutment interface: a finite element analysis
    Shetty, M.
    Hegde, C.
    John, N.
    JOURNAL OF OSSEOINTEGRATION, 2024, 16 (02) : 106 - 113
  • [36] Effect of abutment type and creep behavior on the mechanical properties of implant restorations in the anterior region: A finite element analysis
    Anniwaer, Annikaer
    Yin, Zhengrong
    Zhu, Jiakang
    Huang, Cui
    JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2024, 33 : 93 - 102
  • [37] Strain based in vitro analysis of dental implant using artificial bone model and validation by numerical technique
    Kshirsagar, Mihir
    Dhatrak, Pankaj
    MEDICAL ENGINEERING & PHYSICS, 2023, 111
  • [38] Synthesis of indole based acetohydrazide analogs: Their in vitro and in silico thymidine phosphorylase studies
    Taha, Muhammad
    Aldhamin, Ebaa Ahmed Jassim
    Almandil, Noor Barak
    Anouar, El Hassane
    Uddin, Nizam
    Alomari, Munther
    Rahim, Fazal
    Adalat, Bushra
    Ibrahim, Mohamad
    Nawaz, Fasial
    Iqbal, Naveed
    Alghanem, Bandar
    Altolayyan, Abdulelah
    Khan, Khalid Mohammed
    BIOORGANIC CHEMISTRY, 2020, 98
  • [39] The Role of Implant/Abutment System on Torque Maintenance of Retention Screws and Vertical Misfit of Implant-Supported Crowns Before and After Mechanical Cycling
    Pala Jorge, Juliana Ribeiro
    Ricardo Barao, Valentim Adelino
    Delben, Juliana Aparecida
    Assuncao, Wirley Goncalves
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2013, 28 (02) : 415 - 422
  • [40] A new design of a multifunctional abutment to morse taper implant connection: Experimental mechanical analysis
    Gehrke, Sergio Alexandre
    Dedavid, Berenice Anina
    Fernandes, Gustavo Vicentis de Oliveira
    JOURNAL OF THE MECHANICAL BEHAVIOR OF BIOMEDICAL MATERIALS, 2021, 116