The substitution of the implant and abutment for their analogs in mechanical studies: In vitro and in silico analysis

被引:8
|
作者
Gomes, Rafael Soares [1 ]
Pedroso Bergamo, Edmara Tatiely [1 ]
Bordin, Dimorvan [1 ]
Del Bel Cury, Altair Antoninha [1 ]
机构
[1] Univ Estadual Campinas, Piracicaba Dent Sch, Dept Prosthodont & Periodontol, Av Limeira 901, BR-13414903 Piracicaba, SP, Brazil
来源
MATERIALS SCIENCE AND ENGINEERING C-MATERIALS FOR BIOLOGICAL APPLICATIONS | 2017年 / 75卷
基金
巴西圣保罗研究基金会;
关键词
Dental prosthesis; Dental implants; Mechanical processes; Finite element analysis; CAD/CAM LITHIUM-DISILICATE; FINITE-ELEMENT-ANALYSIS; ALL-CERAMIC CROWNS; FRACTURE-RESISTANCE; STRESS-DISTRIBUTION; FATIGUE; DESIGN; LOAD; RESTORATIONS; STRENGTH;
D O I
10.1016/j.msec.2017.02.034
中图分类号
TB3 [工程材料学]; R318.08 [生物材料学];
学科分类号
0805 ; 080501 ; 080502 ;
摘要
The use of analogs could reduce the cost of mechanical tests involving implant-supported crowns, but it is unclear if it would negatively affect the data accuracy. This study evaluated the substitution of the implant by implants analogs or abutment analogs as a support for crowns in mechanical tests, taking into account stress distribution and fracture load of monolithic lithium disilicate crowns. Thirty lithium disilicate monolithic crowns were randomized into three groups according to the set: Implant + abutment (IA); implant analog + abutment (IAA); abutment analog (AA). The specimens were subjected to mechanical fatigue (10(6) cycles, 200 N, 2 Hz) and thermal fatigue (10(4) cycles, 5 degrees-55 degrees C). A final compression load was applied and the maximum fracture load was recorded. Data were analyzed using one-way ANOVA (alpha = 0.05). The experiment was validated by finite element analysis and the maximum principal stress was recorded. No statistically significant difference was observed in the mean fracture load among groups (P>0.05). The failure mode was similar for all groups with the origin of crack propagation located at the load point application. Finite element analysis showed similar stress distribution and stress peak values for all groups. The use of implant's or abutment's analog does not influence the fracture load and stress distribution for cemented implant-supported crowns. (C) 2017 Elsevier B.V. All rights reserved.
引用
收藏
页码:50 / 54
页数:5
相关论文
共 50 条
  • [21] Influences of implant neck design and implant-abutment joint type on peri-implant bone stress and abutment micromovement: Three-dimensional finite element analysis
    Yamanishi, Yasufumi
    Yamaguchi, Satoshi
    Imazato, Satoshi
    Nakano, Tamaki
    Yatani, Hirofumi
    DENTAL MATERIALS, 2012, 28 (11) : 26 - 33
  • [22] Mechanical Resistance of a 2.9-mm-Diameter Dental Implant With a Morse-Taper Implant-Abutment Connection
    Alberti, Alice
    Corbella, Stefano
    Francetti, Luca
    JOURNAL OF ORAL IMPLANTOLOGY, 2023, 49 (03) : 323 - 329
  • [23] Two Implant/Abutment Joint Designs: A Comparative Finite Element Analysis
    Khraisat, Ameen
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2013, 28 (02) : E83 - E87
  • [24] Analysis of load distribution in tooth-implant supported fixed partial dentures by the use of resilient abutment
    Glisic, Mirko
    Stamenkovic, Dragoslav
    Grbovic, Aleksandar
    Todorovic, Aleksandar
    Markovic, Aleksa
    Trifkovic, Branka
    SRPSKI ARHIV ZA CELOKUPNO LEKARSTVO, 2016, 144 (3-4) : 188 - 195
  • [25] Effect of lubricant on the reliability of dental implant abutment screw joint: An in vitro laboratory and three-dimension finite element analysis
    Wu, Tingting
    Fan, Hongyi
    Ma, Ruiyang
    Chen, Hongyu
    Li, Zhi
    Yu, Haiyang
    MATERIALS SCIENCE AND ENGINEERING C-MATERIALS FOR BIOLOGICAL APPLICATIONS, 2017, 75 : 297 - 304
  • [26] Is It Possible to Monitor Implant Stability on a Prosthetic Abutment? An In Vitro Resonance Frequency Analysis
    Lopez-Jarana, Paula
    Maria Diaz-Castro, Carmen
    Falcao, Artur
    Rios-Carrasco, Blanca
    Fernandez-Palacin, Ana
    Rios-Santos, Jose-Vicente
    Herrero-Climent, Mariano
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH, 2020, 17 (11) : 1 - 14
  • [27] Photoelastic Analysis of Stress Patterns from Different Implant-Abutment Interfaces
    Bernardes, Sergio Rocha
    de Araujo, Cleudmar Amaral
    Fernandes Neto, Alfredo Julio
    Simamoto Junior, Paulo
    das Neves, Flavio Domingues
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2009, 24 (05) : 781 - 789
  • [28] A SENSITIVITY STUDY BY FINITE ELEMENT ANALYSIS FOR THE ABUTMENT-IMPLANT-BONE SYSTEM
    Muraev, A. A.
    Tatoyan, A. D.
    Dolgalev, A. A.
    Vershinin, A. V.
    Yakovlev, M. Ya.
    Ivanov, S. Yu
    Konovalov, D. A.
    Petrovsky, K. A.
    Levin, V. A.
    MATHEMATICS AND MECHANICS OF COMPLEX SYSTEMS, 2022, 10 (01) : 1 - 20
  • [29] Failure Analysis of an Abutment Fracture on Single Implant Restoration
    Imakita, Chiharu
    Shiota, Makoto
    Yamaguchi, Yoko
    Kasugai, Shohei
    Wakabayashi, Noriyuki
    IMPLANT DENTISTRY, 2013, 22 (04) : 326 - 331
  • [30] Nonlinear finite element analysis of three implant-abutment interface designs
    Tang, Chun-Bo
    Liu, Si-Yu
    Zhou, Guo-Xing
    Yu, Jin-Hua
    Zhang, Guang-Dong
    Bao, Yi-Dong
    Wang, Qiu-Ju
    INTERNATIONAL JOURNAL OF ORAL SCIENCE, 2012, 4 (02) : 101 - 108