The substitution of the implant and abutment for their analogs in mechanical studies: In vitro and in silico analysis

被引:8
|
作者
Gomes, Rafael Soares [1 ]
Pedroso Bergamo, Edmara Tatiely [1 ]
Bordin, Dimorvan [1 ]
Del Bel Cury, Altair Antoninha [1 ]
机构
[1] Univ Estadual Campinas, Piracicaba Dent Sch, Dept Prosthodont & Periodontol, Av Limeira 901, BR-13414903 Piracicaba, SP, Brazil
来源
MATERIALS SCIENCE AND ENGINEERING C-MATERIALS FOR BIOLOGICAL APPLICATIONS | 2017年 / 75卷
基金
巴西圣保罗研究基金会;
关键词
Dental prosthesis; Dental implants; Mechanical processes; Finite element analysis; CAD/CAM LITHIUM-DISILICATE; FINITE-ELEMENT-ANALYSIS; ALL-CERAMIC CROWNS; FRACTURE-RESISTANCE; STRESS-DISTRIBUTION; FATIGUE; DESIGN; LOAD; RESTORATIONS; STRENGTH;
D O I
10.1016/j.msec.2017.02.034
中图分类号
TB3 [工程材料学]; R318.08 [生物材料学];
学科分类号
0805 ; 080501 ; 080502 ;
摘要
The use of analogs could reduce the cost of mechanical tests involving implant-supported crowns, but it is unclear if it would negatively affect the data accuracy. This study evaluated the substitution of the implant by implants analogs or abutment analogs as a support for crowns in mechanical tests, taking into account stress distribution and fracture load of monolithic lithium disilicate crowns. Thirty lithium disilicate monolithic crowns were randomized into three groups according to the set: Implant + abutment (IA); implant analog + abutment (IAA); abutment analog (AA). The specimens were subjected to mechanical fatigue (10(6) cycles, 200 N, 2 Hz) and thermal fatigue (10(4) cycles, 5 degrees-55 degrees C). A final compression load was applied and the maximum fracture load was recorded. Data were analyzed using one-way ANOVA (alpha = 0.05). The experiment was validated by finite element analysis and the maximum principal stress was recorded. No statistically significant difference was observed in the mean fracture load among groups (P>0.05). The failure mode was similar for all groups with the origin of crack propagation located at the load point application. Finite element analysis showed similar stress distribution and stress peak values for all groups. The use of implant's or abutment's analog does not influence the fracture load and stress distribution for cemented implant-supported crowns. (C) 2017 Elsevier B.V. All rights reserved.
引用
收藏
页码:50 / 54
页数:5
相关论文
共 50 条
  • [1] The Effects of Simulated Bone Loss on the Implant-Abutment Assembly and Likelihood of Fracture: An In Vitro Study
    Manzoor, Behzad
    Suleiman, Mahmood
    Palmer, Richard M.
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2013, 28 (03) : 729 - 738
  • [2] In vitro performance of zirconia and titanium implant/abutment systems for anterior application
    Rosentritt, Martin
    Hagemann, Anna
    Hahnel, Sebastian
    Behr, Michael
    Preis, Verena
    JOURNAL OF DENTISTRY, 2014, 42 (08) : 1019 - 1026
  • [3] Analysis of the Mechanical Behavior and Effect of Cyclic Fatigue on the Implant-Abutment Interface
    German Sandoval, Ramon
    Ortiz Magdaleno, Marine
    Sanchez Robles, Paula
    Zavala Alonso, Norma
    Romo Ramirez, Gabriel Fernando
    ODOVTOS INTERNATIONAL JOURNAL OF DENTAL SCIENCES, 2021, 23 (02) : 104 - 114
  • [4] Mechanical effect of taper position in abutment hole and screw taper angles on implant system and peri-implant tissue: a finite element analysis
    Hou, Hu
    Zhang, Jianguo
    Huang, Song
    Hu, Fengling
    Yu, Youcheng
    Song, Liang
    COMPUTER METHODS IN BIOMECHANICS AND BIOMEDICAL ENGINEERING, 2024,
  • [5] Mechanical Evaluation of an Implant-Abutment Self-Locking Taper Connection: Finite Element Analysis and Experimental Tests
    Sannino, Gianpaolo
    Barlattani, Alberto
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2013, 28 (01) : E17 - E26
  • [6] The Mechanical Behavior of a Screwless Morse Taper Implant-Abutment Connection: An In Vitro Study
    Bagegni, Aimen
    Weihrauch, Vincent
    Vach, Kirstin
    Kohal, Ralf
    MATERIALS, 2022, 15 (09)
  • [7] Mechanical Testing of Implant-Supported Anterior Crowns with Different Implant/Abutment Connections
    Almeida, Erika O.
    Freitas, Amilcar C., Jr.
    Bonfante, Estevam A.
    Marotta, Leonard
    Silva, Nelson R. F. A.
    Coelho, Paulo G.
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2013, 28 (01) : 103 - 108
  • [8] The effect of abutment material stiffness on the mechanical behavior of dental implant assemblies: A 3D finite element study
    Tonin, Bruna S. H.
    Fu, Jing
    He, Yiting
    Ye, Ning
    Chew, Hooi Pin
    Fok, Alex
    JOURNAL OF THE MECHANICAL BEHAVIOR OF BIOMEDICAL MATERIALS, 2023, 142
  • [9] In vitro analysis of prosthetic abutment and angulable frictional implant interface adaptation: Mechanical and microbiological study
    Vilela Junior, Rafael de Aguiar
    Aranha, Luis Claudio
    Elias, Carlos Nelson
    Martinez, Elizabeth Ferreira
    JOURNAL OF BIOMECHANICS, 2021, 128
  • [10] A Strain Gauge Analysis Comparing External and Internal Implant-Abutment Connections
    Asvanund, Pattapon
    IMPLANT DENTISTRY, 2014, 23 (02) : 206 - 211