Dynamic analysis and sizing optimization of a pumped hydroelectric storage-integrated hybrid PV/Wind system: A case study

被引:123
作者
Nassar, Yasser F. [1 ]
Abdunnabi, Mohammad J. [2 ]
Sbeta, Mohamed N. [2 ]
Hafez, Ahmad A. [3 ]
Amer, Khaled A. [1 ]
Ahmed, Abdulaziz Y. [1 ]
Belgasim, Basim [2 ,4 ]
机构
[1] Sebha Univ, Fac Engn & Tech, Mech & Ind Engn Dept, Sabha, Libya
[2] Ctr Solar Energy Res & Studies CSERS, POB 12932, Tajura, Libya
[3] Assiut Univ, Elect Engn Dept, Fac Engn, Assiut, Egypt
[4] Univ Benghazi, Mech Engn Dept, Benghazi, Libya
关键词
Energy storage; Hybrid system; PV field; Wind farm; Pumped hydroelectric storage; Sizing optimization;
D O I
10.1016/j.enconman.2020.113744
中图分类号
O414.1 [热力学];
学科分类号
摘要
The intermittent nature of variable renewable energy resources in conjunction with the fluctuating energy demand of load require using an efficient long-term energy storage means. Pumped Hydroelectric Storage (PHS) has proved its commercial viability as electricity storage technology and eligibility to be coupled with the Renewable Energy Systems (RESs). This paper proposes a simple and efficient procedure for optimal sizing of PHS-integrated hybrid PV/Wind power system for providing sustainable supply of electricity to an urban community in Brack city (27. 32'N, 14. 17'E), Libya. The sizing procedure is considered as a constrained optimization problem. The constraints are developed to consider the operating conditions and the output uncertainty of RESs. The sizing algorithm and optimization procedure are explicitly described. Different operating scenarios were considered to identify the optimal size of the hybrid PV/Wind energy system and PHS. Using the measured date of climate conditions and load consumption, the energy production for different sizes of solar PV arrays and wind turbine farms were estimated by System Advisory Model (SAM) software. Based on the Levelized Cost Of Energy (LCOE), the optimum power capacity ratio of PV array to wind turbines farm was 1:5. For the system of optimal size, PHS contribute with a share of 15 % in covering the annual load energy. The obtained results revealed that coupling the hybrid RESs with PHS is cost competitive and reliable alternative for providing sustainable energy supply to urban areas of suitable topographical conditions and high potential of renewable energy resources.
引用
收藏
页数:17
相关论文
共 34 条
  • [1] On the sizing parameters for stand-alone solar-energy systems
    Agha, KR
    Sbita, MN
    [J]. APPLIED ENERGY, 2000, 65 (1-4) : 73 - 84
  • [2] Ahmad, 2016, INT J ENERGY POLICY, V1, P64
  • [3] Alsadi, 2018, J ECOLOGICAL SCI, V6, P63
  • [4] Angjelichinoski M, 2017, MICROGRID: ADVANCED CONTROL METHODS AND RENEWABLE ENERGY SYSTEM INTEGRATION, P311, DOI 10.1016/B978-0-08-101753-1.00011-5
  • [5] [Anonymous], 2020, ELECT STORAGE RENEWA
  • [6] [Anonymous], TOPOGRAPHIC MAPS WOR
  • [7] [Anonymous], Renewable Power Generation Costs in 2020
  • [8] [Anonymous], LIBYA RENEWABLE ENER
  • [9] The potential of concentrating solar power (CSP) for electricity generation in Libya
    Belgasim, Basim
    Aldali, Yasser
    Abdunnabi, Mohammad J. R.
    Hashem, Gamal
    Hossin, Khaled
    [J]. RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2018, 90 : 1 - 15
  • [10] Spatial and temporal variation in the value of solar power across United States electricity markets
    Brown, Patrick R.
    O'Sullivan, Francis M.
    [J]. RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2020, 121